MAASTRO applicator, a novel rectal applicator for contact brachytherapy with 192Ir HDR sources

dc.contributor.authorBELLEZZO, M.pt_BR
dc.contributor.authorFONSECA, G.P.pt_BR
dc.contributor.authorVONCKEN, R.pt_BR
dc.contributor.authorVERRIJSSEN, A.pt_BR
dc.contributor.authorVAN BEVEREN, C.pt_BR
dc.contributor.authorROELOFS, E.pt_BR
dc.contributor.authorYORIYAZ, H.pt_BR
dc.contributor.authorRENIERS, B.pt_BR
dc.contributor.authorVAN LIMBERGEN, E.J.pt_BR
dc.contributor.authorBARBEE, M.pt_BR
dc.contributor.authorVERHAEGEN, F.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2022-02-04T14:35:15Z
dc.date.available2022-02-04T14:35:15Z
dc.date.issued2020pt_BR
dc.description.abstractPurpose or Objective: The standard care for rectal cancer includes surgery, which may be avoided if complete response is achieved, e.g. with chemoradiotherapy (EBCRT) or external beam radiotherapy EBRT, adopting a watch and wait strategy. Studies report a local regrowth reduction from 30% (EBCRT alone) to 11% when EBCRT is associated with a radiation boost using 50 kV x-rays (CXB), technique that allows a high dose delivery to a highly selective volume, allowing preservation of organs at risk (OAR) and low toxicity. However, CXB is not widely adopted due to its low costeffectiveness. Hence, the MAASTRO applicator was developed to deliver a dose distribution similar to those generated by CXB devices, but using HDR 192Ir sources, as a cost-effective alternative to CXB, with possibility of integration to treatment planning systems (TPS). Material and Methods: Fig 1-a shows the applicator design, a cylindrical applicator with 5 channels and a slanted edge, using its tip. Results: Due to the applicator geometry, the most distal position of the source in each channel doesn’t reach the sharp edge of the applicator, resulting in an effective treatment surface (high dose region shown in Fig 1 a and b) of approximately 20 x 20 mm2, which is smaller than the contact surface. The resulting dose falloff is steeper than the one resulting from the P50 with a 22 mm applicator. With the dose falloff normalized at 2mm, the relative dose values delivered at depths of 0, 2, 5 and 10 mm are, respectively, 130, 100, 70 and 43% for the P50 and 140, 100, 67 and 38% for the applicator. The time required to deliver an average dose of 32 Gy to the treatment surface of the applicator is 5m30s for a 40700 U source (new source) and 8m30s for a 20350 U source (source to be replaced), including the time required to perform obstruction verification before irradiation. The applicator delivers a high dose to a small target volume while the lateral shielding spares normal tissues in all directions other than the contact surface. Conclusion: The MAASTRO applicator was designed to deliver dose distributions similar to those of CXB devices using 192Ir HDR sources. The applicator has the advantage of TPS integration, increasing the degrees of freedom to modulate the dose distribution.pt_BR
dc.format.extentS1102-S1103pt_BR
dc.identifier.citationBELLEZZO, M.; FONSECA, G.P.; VONCKEN, R.; VERRIJSSEN, A.; VAN BEVEREN, C.; ROELOFS, E.; YORIYAZ, H.; RENIERS, B.; VAN LIMBERGEN, E.J.; BARBEE, M.; VERHAEGEN, F. MAASTRO applicator, a novel rectal applicator for contact brachytherapy with 192Ir HDR sources. <b>Radiotherapy and Oncology</b>, v. 152, p. S1102-S1103, 2020. Supplement 1. DOI: <a href="https://dx.doi.org/10.1016/S0167-8140(21)01990-3">10.1016/S0167-8140(21)01990-3</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/32694.
dc.identifier.doi10.1016/S0167-8140(21)01990-3pt_BR
dc.identifier.issn0167-8140pt_BR
dc.identifier.orcid0000-0003-4023-236Xpt_BR
dc.identifier.orcidhttps://orcid.org/0000-0003-4023-236X
dc.identifier.percentilfi82.67pt_BR
dc.identifier.percentilfiCiteScore87.67pt_BR
dc.identifier.suplementoSupplement 1pt_BR
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/32694
dc.identifier.vol152pt_BR
dc.relation.ispartofRadiotherapy and Oncologypt_BR
dc.rightsopenAccesspt_BR
dc.sourceESTRO, November 28 - December 1, 2020, Onlinept_BR
dc.titleMAASTRO applicator, a novel rectal applicator for contact brachytherapy with 192Ir HDR sourcespt_BR
dc.typeResumos em periódicospt_BR
dspace.entity.typePublication
ipen.autorMURILLO BELLEZZO
ipen.autorHELIO YORIYAZ
ipen.codigoautor10246
ipen.codigoautor80
ipen.contributor.ipenauthorMURILLO BELLEZZO
ipen.contributor.ipenauthorHELIO YORIYAZ
ipen.date.recebimento22-02
ipen.identifier.fi6.280pt_BR
ipen.identifier.fiCiteScore8.0pt_BR
ipen.identifier.ipendoc28461pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi6.000 ou mais
ipen.range.percentilfi75.00 - 100.00
ipen.type.genreResumo
relation.isAuthorOfPublicationfbb6d3c2-9f6b-43d0-947e-d4de7792bee3
relation.isAuthorOfPublication93102dac-f89d-4743-b6ea-5158708cbb92
relation.isAuthorOfPublication.latestForDiscoveryfbb6d3c2-9f6b-43d0-947e-d4de7792bee3
sigepi.autor.atividadeYORIYAZ, H.:80:420:Npt_BR
sigepi.autor.atividadeBELLEZZO, M.:10246:420:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
28461.pdf
Tamanho:
477.84 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: