Evaluation of the behavior of a 180cc ionization chamber under different environmental conditions

dc.contributor.authorSILVA, E.pt_BR
dc.contributor.authorSANTOS, L.R.pt_BR
dc.contributor.authorASSEMANY, L.P.F.pt_BR
dc.contributor.authorPOTIENS, M.P.A.pt_BR
dc.coverageNacionalpt_BR
dc.creator.eventoCONGRESSO BRASILEIRO DE METROLOGIA, 10.; CONGRESSO INTERNACIONAL DE METROLOGIA ELÉTRICA, 13.; CONGRESSO INTERNACIONAL DE METROLOGIA MECÂNICA, 5.; CONGRESSO BRASILEIRO DE METROLOGIA DAS RADIAÇÕES IONIZANTES, 6.; WORKSHOP DA REDE DE METROLOGIA QUÍMICA DO INMETRO, 4.; CONGRESSO BRASILEIRO DE METROLOGIA ÓPTICA, 3.pt_BR
dc.date.accessioned2020-03-24T19:24:49Z
dc.date.available2020-03-24T19:24:49Z
dc.date.evento24-27 de novembro, 2019pt_BR
dc.description.abstractThe use of ionizing radiation for medical purposes has been a major advance for society due to the numerous possibilities of use for the treatment and diagnosis of diseases. On the other hand, knowledge about the damage caused by the biological effects of ionizing radiation requires continuous improvement of diagnostic radiology quality control. Radiation detector equipment is used to measure radiation levels emitted from natural or artificial sources. For convenience and accuracy, among the most widely used detectors are ionization chambers. Especially outdoors, weather factors can affect the behavior of these detectors at the time of measurement, but Brazilian law recommends only calibrating these measuring instruments in a traceable laboratory every two years to ensure their reliability. The objective of this work was to evaluate the performance of an ionization chamber used in radioprotection measurements in diagnostic radiology equipment, considering climatic variations in different regions of Brazil. For this, a system was developed to simulate the environmental conditions found for the temperature and humidity parameters at the moment of the clinical measurements, allowing to estimate the influence of these factors on the obtained values.pt_BR
dc.identifier.citationSILVA, E.; SANTOS, L.R.; ASSEMANY, L.P.F.; POTIENS, M.P.A. Evaluation of the behavior of a 180cc ionization chamber under different environmental conditions. In: CONGRESSO BRASILEIRO DE METROLOGIA, 10.; CONGRESSO INTERNACIONAL DE METROLOGIA ELÉTRICA, 13.; CONGRESSO INTERNACIONAL DE METROLOGIA MECÂNICA, 5.; CONGRESSO BRASILEIRO DE METROLOGIA DAS RADIAÇÕES IONIZANTES, 6.; WORKSHOP DA REDE DE METROLOGIA QUÍMICA DO INMETRO, 4.; CONGRESSO BRASILEIRO DE METROLOGIA ÓPTICA, 3., 24-27 de novembro, 2019, Florianópolis, SC. <b>Anais...</b> Rio de Janeiro, RJ: Sociedade Brasileira de Metrologia, 2019. Disponível em: http://repositorio.ipen.br/handle/123456789/30941.
dc.identifier.orcid0000-0002-4049-6720pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-4049-6720
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/30941
dc.localRio de Janeiro, RJpt_BR
dc.local.eventoFlorianópolis, SCpt_BR
dc.publisherSociedade Brasileira de Metrologiapt_BR
dc.rightsopenAccesspt_BR
dc.subjectionization chambers
dc.subjectnuclear medicine
dc.subjectperformance testing
dc.subjectquality control
dc.subjectradiation metrology
dc.subjectradiation protection
dc.subjectradiology
dc.titleEvaluation of the behavior of a 180cc ionization chamber under different environmental conditionspt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorEZEQUIEL DA SILVA
ipen.autorLADYJANE PEREIRA FONTES
ipen.autorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.autorLUCAS RODRIGUES DOS SANTOS
ipen.codigoautor14448
ipen.codigoautor12137
ipen.codigoautor346
ipen.codigoautor8725
ipen.contributor.ipenauthorEZEQUIEL DA SILVA
ipen.contributor.ipenauthorLADYJANE PEREIRA FONTES
ipen.contributor.ipenauthorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.contributor.ipenauthorLUCAS RODRIGUES DOS SANTOS
ipen.date.recebimento20-03
ipen.event.datapadronizada2019pt_BR
ipen.identifier.ipendoc26747pt_BR
ipen.notas.internasAnaispt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublicationb6a92541-f490-4507-acfc-7bf78b745681
relation.isAuthorOfPublication00349d21-f362-4498-a5c0-691c31365fa4
relation.isAuthorOfPublication30f213ae-321d-4d51-8763-0a2585255fb9
relation.isAuthorOfPublicationc7dbb34c-9e7b-4d45-bffd-57381fc9c260
relation.isAuthorOfPublication.latestForDiscoveryb6a92541-f490-4507-acfc-7bf78b745681
sigepi.autor.atividadePOTIENS, M.P.A.:346:330:Npt_BR
sigepi.autor.atividadeASSEMANY, L.P.F.:12137:330:Npt_BR
sigepi.autor.atividadeSANTOS, L.R.:8725:330:Npt_BR
sigepi.autor.atividadeSILVA, E.:14448:330:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
26747.pdf
Tamanho:
301.95 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções