Standardization of sup(241)Am by means of coincidence system using 4 pi plastic scintillator detector

dc.contributor.authorBACCARELLI, A.M.pt_BR
dc.contributor.authorDIAS, M.S.pt_BR
dc.contributor.authorKOSKINAS, M.F.pt_BR
dc.coverageNacionalpt_BR
dc.creator.eventoREGIONAL CONGRESS ON RADIATION PROTECTION AND SAFETY, 5th, REGIONAL IRPA CONGRESSpt_BR
dc.date.accessioned2014-11-17T17:50:47Zpt_BR
dc.date.accessioned2014-11-18T18:04:18Zpt_BR
dc.date.accessioned2015-04-02T04:39:58Z
dc.date.available2014-11-17T17:50:47Zpt_BR
dc.date.available2014-11-18T18:04:18Zpt_BR
dc.date.available2015-04-02T04:39:58Z
dc.date.eventoApr. 29 - May 4, 2001pt_BR
dc.description.abstractA 4nt (a,(3)- y coincidence system using a plastic scintillator detector in 47t geometry has been developed and applied for the standardization of 241Am. The scintillator shape and dimensions have been optimized for maximum charge particle detection efficiency, while keeping background low and a nearly constant gamma ray efficiency for different points at the radioactive source. The gamma ray events were measured with 3" x 3" NaI(Tl) scintillation counter. The electronic system for processing pulses consisted of logic gates and delay modules feeding a Time to Amplitude Converter with output to a Multichannel Analyser. The alpha detection efficiency measured with 241Am resulted around 95% and the beta detection efficiency measured with 60Co was around 60%. Activity measurements of 241Am were compared with a conventional system employing a 4it proportional counter and showed good agreement.
dc.identifier.citationBACCARELLI, A.M.; DIAS, M.S.; KOSKINAS, M.F. Standardization of sup(241)Am by means of coincidence system using 4 pi plastic scintillator detector. In: REGIONAL CONGRESS ON RADIATION PROTECTION AND SAFETY, 5th, REGIONAL IRPA CONGRESS, Apr. 29 - May 4, 2001, Recife, PE. <b>Proceedings...</b> Disponível em: http://repositorio.ipen.br/handle/123456789/15241.
dc.identifier.orcidhttps://orcid.org/0000-0001-8407-9833
dc.identifier.orcidhttps://orcid.org/0000-0003-2478-5757
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/15241pt_BR
dc.local.eventoRecife, PEpt_BR
dc.publisherRecife: SBPR, 2001pt_BR
dc.rightsopenAccess
dc.subjectamericium 241pt_BR
dc.subjectstandardizationpt_BR
dc.subjectplastic scintillation detectorspt_BR
dc.subjectnai detectorspt_BR
dc.subjectcoincidence methodspt_BR
dc.subjectgamma radiationpt_BR
dc.subjectalpha detectionpt_BR
dc.subjectbeta detectionpt_BR
dc.subjectcobalt 60pt_BR
dc.subjectradioactivitypt_BR
dc.titleStandardization of sup(241)Am by means of coincidence system using 4 pi plastic scintillator detectorpt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorAIDA MARIA BACCARELLI
ipen.autorMARINA FALLONE KOSKINAS
ipen.autorMAURO DA SILVA DIAS
ipen.codigoautor2578
ipen.codigoautor1387
ipen.codigoautor1292
ipen.contributor.ipenauthorAIDA MARIA BACCARELLI
ipen.contributor.ipenauthorMARINA FALLONE KOSKINAS
ipen.contributor.ipenauthorMAURO DA SILVA DIAS
ipen.date.recebimento01-06pt_BR
ipen.event.datapadronizada2001pt_BR
ipen.identifier.ipendoc07102pt_BR
ipen.notas.internasProceedingspt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublicationfbb95554-7a26-4298-a117-8f15a802b9c8
relation.isAuthorOfPublication420a8816-64da-4bb8-a1c4-5b8b638033b1
relation.isAuthorOfPublication58653850-db59-4051-aa72-5c32a5f6670e
relation.isAuthorOfPublication.latestForDiscovery58653850-db59-4051-aa72-5c32a5f6670e
sigepi.autor.atividadeBACCARELLI, A.M.:2578:-1:Spt_BR
sigepi.autor.atividadeDIAS, M.S.:1292:6:Npt_BR
sigepi.autor.atividadeKOSKINAS, M.F.:1387:6:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
07102.pdf
Tamanho:
27.09 KB
Formato:
Adobe Portable Document Format

Coleções