Interpolation studies of a 3D dosimetric system for quality assurance in radiation therapy

dc.contributor.authorMAZER, AMANDA Cpt_BR
dc.contributor.authorSHORTO, JULIAN M.B.pt_BR
dc.contributor.authorSIQUEIRA, PAULO T.D.pt_BR
dc.contributor.authorNAKANDAKARI, MARCOS V.N.pt_BR
dc.contributor.authorRIBEIRO, VICTOR A.B.pt_BR
dc.contributor.authorYORIYAZ, HELIOpt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL NUCLEAR ATLANTIC CONFERENCEpt_BR
dc.date.accessioned2019-11-27T12:17:49Z
dc.date.available2019-11-27T12:17:49Z
dc.date.eventoOctober 21-25, 2019pt_BR
dc.description.abstractWith the evolution of radiation therapy techniques, treatments have become increasingly accurate. To ensure a good quality assurance program for modern equipment, Sun Nuclear Corporation has developed ArcCHECK, a 3D dosimetric system, which contains 1386 helically arranged diodes within a PMMA cylindrical structure. The outputs of this system show, in addition to dose values acquired directly from the diodes, also matrices with interpolated dose values, in order to provide values at more than 5000 points for quality assurance. The main purpose of this work is to analyze the interpolated dose values provided by ArcCHECK. For this, simple measurements were taken with ArcCHECK, with a 10x10 cm2 static field of 6 MeV photons and 100 MU. A algorithm for MATLAB software was also developed so that it was possible to interpolate crude dose values obtained from the diodes and compare them with the values interpolated by the dosimetric system software. Significant dose differences values were found in the relative dose difference between the matrices interpolated by the algorithm and by ArcCHECK. The method used by this dosimetric system presented a diode selection pattern for the interpolation and different when compared to the developed method, even if both were calculated in the 2D plane, based on the dose map acquired by ArcCHECK.pt_BR
dc.event.siglaINACpt_BR
dc.format.extent153-160pt_BR
dc.identifier.citationMAZER, AMANDA C; SHORTO, JULIAN M.B.; SIQUEIRA, PAULO T.D.; NAKANDAKARI, MARCOS V.N.; RIBEIRO, VICTOR A.B.; YORIYAZ, HELIO. Interpolation studies of a 3D dosimetric system for quality assurance in radiation therapy. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. <b>Proceedings...</b> Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 153-160. Disponível em: http://repositorio.ipen.br/handle/123456789/30343.
dc.identifier.orcid0000-0003-4023-236Xpt_BR
dc.identifier.orcid0000-0003-2281-5756pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0003-4023-236X
dc.identifier.orcidhttps://orcid.org/0000-0003-4817-5275
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/30343
dc.localRio de Janeiropt_BR
dc.local.eventoSantos, SPpt_BR
dc.publisherAssociação Brasileira de Energia Nuclear
dc.rightsopenAccesspt_BR
dc.subjectalgorithms
dc.subjectcomputerized simulation
dc.subjectdose rates
dc.subjectdosemeters
dc.subjectdosimetry
dc.subjectinterpolation
dc.subjectmonte carlo method
dc.subjectphotons
dc.subjectquality assurance
dc.subjectradiation doses
dc.subjectradiotherapy
dc.titleInterpolation studies of a 3D dosimetric system for quality assurance in radiation therapypt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorHELIO YORIYAZ
ipen.autorPAULO DE TARSO DALLEDONE SIQUEIRA
ipen.autorJULIAN MARCO BARBOSA SHORTO
ipen.autorAMANDA CRISTINA MAZER
ipen.codigoautor80
ipen.codigoautor968
ipen.codigoautor9690
ipen.codigoautor14567
ipen.contributor.ipenauthorHELIO YORIYAZ
ipen.contributor.ipenauthorPAULO DE TARSO DALLEDONE SIQUEIRA
ipen.contributor.ipenauthorJULIAN MARCO BARBOSA SHORTO
ipen.contributor.ipenauthorAMANDA CRISTINA MAZER
ipen.date.recebimento19-11
ipen.event.datapadronizada2019pt_BR
ipen.identifier.ipendoc26131pt_BR
ipen.notas.internasProceedingspt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication93102dac-f89d-4743-b6ea-5158708cbb92
relation.isAuthorOfPublication24db5afe-fc9a-4cc0-9be3-2c5035796315
relation.isAuthorOfPublication91a9cbb6-cd24-480c-a65d-dd1c309a1622
relation.isAuthorOfPublication5dd1b885-96c2-4313-b6fb-3d5b8f2d6c9f
relation.isAuthorOfPublication.latestForDiscovery5dd1b885-96c2-4313-b6fb-3d5b8f2d6c9f
sigepi.autor.atividadeYORIYAZ, HELIO:80:420:Npt_BR
sigepi.autor.atividadeSIQUEIRA, PAULO T.D.:968:420:Npt_BR
sigepi.autor.atividadeSHORTO, JULIAN M.B.:9690:420:Npt_BR
sigepi.autor.atividadeMAZER, AMANDA C:14567:420:Spt_BR
Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
26131.pdf
Tamanho:
1.06 MB
Formato:
Adobe Portable Document Format
Descrição:
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Coleções