Calibration of the short irradiation facility for K0 − NAA implementation at the IEA-R1 Reactor

dc.contributor.authorOLIVEIRA, J.P.pt_BR
dc.contributor.authorSILVA, P.S.C.pt_BR
dc.contributor.authorSEMMLER, R.pt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL NUCLEAR ATLANTIC CONFERENCEpt_BR
dc.date.accessioned2019-11-28T11:35:30Z
dc.date.available2019-11-28T11:35:30Z
dc.date.eventoOctober 21-25, 2019pt_BR
dc.description.abstractThe short irradiation facility of the IEA-R1 nuclear research reactor at IPEN, S~ao Paulo, Brazil, has been used for short irradiation of samples for the purpose of determining the concentration of elements of these samples through the use of the instrumental neutron activation analysis technique. With the aim of implementing the k0-NAA method at the Neutron Activation Analysis Laboratory (LAN), the reactor parameters and f were obtained using the bare triple method. In this method, a set of three neutron ux monitors were irradiated without Cd-cover. The e ciency curve of the gamma-ray spectrometer used were determined by measuring calibrated radioactive sources at the usually utilized counting geometries. The results obtained for the parameters and f were respectively 0:0384 0:0016 and 35:67 0:26. The obtained value of f shows that the neutrons in the irradiation position are well thermalized, in other words, the value of f, means that thermal neutron ux is 35 times higher than epithermal neutron ux. It means that this irradiation position is well thermalized. The variation of these parameters was studied with time and the reproducibility was veri ed.pt_BR
dc.event.siglaINACpt_BR
dc.format.extent454-458pt_BR
dc.identifier.citationOLIVEIRA, J.P.; SILVA, P.S.C.; SEMMLER, R. Calibration of the short irradiation facility for K0 − NAA implementation at the IEA-R1 Reactor. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. <b>Proceedings...</b> Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 454-458. Disponível em: http://repositorio.ipen.br/handle/123456789/30367.
dc.identifier.orcid0000-0001-7733-0153pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-7733-0153
dc.identifier.orcidhttps://orcid.org/0000-0002-9351-9201
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/30367
dc.localRio de Janeiropt_BR
dc.local.eventoSantos, SPpt_BR
dc.publisherAssociação Brasileira de Energia Nuclear
dc.rightsopenAccesspt_BR
dc.subjectcalibration
dc.subjectcobalt 60
dc.subjecthigh-purity ge detectors
dc.subjectiear-1 reactor
dc.subjectirradiation
dc.subjectneutron activation analysis
dc.subjectneutron flux
dc.titleCalibration of the short irradiation facility for K0 − NAA implementation at the IEA-R1 Reactorpt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorRENATO SEMMLER
ipen.autorPAULO SERGIO CARDOSO DA SILVA
ipen.autorJOAO PEDRO DE OLIVEIRA FLORES
ipen.codigoautor833
ipen.codigoautor2777
ipen.codigoautor10625
ipen.contributor.ipenauthorRENATO SEMMLER
ipen.contributor.ipenauthorPAULO SERGIO CARDOSO DA SILVA
ipen.contributor.ipenauthorJOAO PEDRO DE OLIVEIRA FLORES
ipen.date.recebimento19-11
ipen.event.datapadronizada2019pt_BR
ipen.identifier.ipendoc26150pt_BR
ipen.notas.internasProceedingspt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublicationf95a9324-04eb-409b-86b2-97eaa10134f2
relation.isAuthorOfPublicationaa898df6-ea14-482c-bc29-b45954bb0542
relation.isAuthorOfPublicationc5e02eba-4be0-4bc3-8e21-1cbf697b3a55
relation.isAuthorOfPublication.latestForDiscoveryc5e02eba-4be0-4bc3-8e21-1cbf697b3a55
sigepi.autor.atividadeSEMMLER, R.:833:310:Npt_BR
sigepi.autor.atividadeSILVA, P.S.C.:2777:320:Npt_BR
sigepi.autor.atividadeOLIVEIRA, J.P.:10625:310:Spt_BR
Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
26150.pdf
Tamanho:
283.86 KB
Formato:
Adobe Portable Document Format
Descrição:
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Coleções