Optical and histological evaluation of human tendon tissue sterilized by ionizing radiation

dc.contributor.authorFUNARI, ANA P.
dc.contributor.authorANTEBI, URI
dc.contributor.authorSANTOS, LUIZ A.
dc.contributor.authorVIEIRA, DANIEL P.
dc.contributor.authorMIRANDA, JURANDIR T. de
dc.contributor.authorALVES, NELSON M.
dc.contributor.authorFREITAS, ANDERSON Z. de
dc.contributor.authorMATHOR, MONICA B.
dc.coverageInternacionalpt_BR
dc.date.accessioned2019-02-27T13:21:16Z
dc.date.available2019-02-27T13:21:16Z
dc.date.issued2018pt_BR
dc.description.abstractSterilization by irradiation is a technique that is used by tissue banks aiming to eliminate contamination of human allografts, being a safe method, free of residue and used as final sterilization. After the tissue procurement, these undergo a series of processing stages and then are packaged and preserved by freezing. Despite aseptic care of the material those may be subjected to sterilization in the final packing by ionizing radiation, raising the security level of sterility of the tissue. The aim of this study was to evaluate the effects of application of ionizing radiation, produced by 60Co source in human tendons preprocessed (A-alcohol + antibiotic; B- H2O2 + ultrasound) obtained through collaboration with tissue banks and preserved by freezing in -80° C, the radiation absorbed doses in processing were 12.5, 15 and 25 kGy, each one with their corresponding non-irradiated control, to examine possible structural or morphological alterations. The irradiated samples and their controls were analyzed by means of optical coherence tomography (OCT) and optical coherence tomography polarization sensitive (PS-OCT), and histological tests had been stained with hematoxylin-eosin (HE). According to the results the tissue processed with alcohol/antibiotic in conjunction with irradiation proved to be the most effective.pt_BR
dc.format.extent122-122pt_BR
dc.identifier.citationFUNARI, ANA P.; ANTEBI, URI; SANTOS, LUIZ A.; VIEIRA, DANIEL P.; MIRANDA, JURANDIR T. de; ALVES, NELSON M.; FREITAS, ANDERSON Z. de; MATHOR, MONICA B. Optical and histological evaluation of human tendon tissue sterilized by ionizing radiation. <b>Regenerative Research</b>, v. 7, n. 1, p. 122-122, 2018. Disponível em: http://repositorio.ipen.br/handle/123456789/29715.
dc.identifier.fasciculo1pt_BR
dc.identifier.issn2232-0822pt_BR
dc.identifier.orcidaguardandopt_BR
dc.identifier.orcidhttp://orcid.org/0000-0002-7294-9106
dc.identifier.orcidhttps://orcid.org/0000-0002-5018-9126
dc.identifier.orcidhttps://orcid.org/0000-0002-0007-534X
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/29715
dc.identifier.vol7pt_BR
dc.relation.ispartofRegenerative Researchpt_BR
dc.rightsopenAccesspt_BR
dc.subjectabsorbed radiation doses
dc.subjectalcohols
dc.subjectanimal tissues
dc.subjectantibiotics
dc.subjectcobalt 60
dc.subjectfreezing
dc.subjecthistological techniques
dc.subjectionizing radiations
dc.subjectradiation effects
dc.subjectsterilization
dc.subjecttendons
dc.subjecttomography
dc.titleOptical and histological evaluation of human tendon tissue sterilized by ionizing radiationpt_BR
dc.typeResumos em periódicospt_BR
dspace.entity.typePublication
ipen.autorMONICA BEATRIZ MATHOR
ipen.autorANDERSON ZANARDI DE FREITAS
ipen.autorDANIEL PEREZ VIEIRA
ipen.autorANA PAULA FUNARI
ipen.codigoautor209
ipen.codigoautor880
ipen.codigoautor3158
ipen.codigoautor12703
ipen.contributor.ipenauthorMONICA BEATRIZ MATHOR
ipen.contributor.ipenauthorANDERSON ZANARDI DE FREITAS
ipen.contributor.ipenauthorDANIEL PEREZ VIEIRA
ipen.contributor.ipenauthorANA PAULA FUNARI
ipen.date.recebimento19-02pt_BR
ipen.identifier.fiSem F.I.pt_BR
ipen.identifier.ipendoc25540pt_BR
ipen.type.genreResumo
relation.isAuthorOfPublication742b424f-9dfb-4e4a-993b-000052bb1313
relation.isAuthorOfPublicationa8d821f0-a0a4-4d52-b582-5c5d0afce8f5
relation.isAuthorOfPublicationc2352608-be9c-4a73-be8c-571f10bb53d2
relation.isAuthorOfPublication94572559-f50c-4358-85c2-503d7fc847bf
relation.isAuthorOfPublication.latestForDiscovery94572559-f50c-4358-85c2-503d7fc847bf
sigepi.autor.atividadeFUNARI, ANA P.:12703:230:Spt_BR
sigepi.autor.atividadeVIEIRA, DANIEL P.:3158:810:Npt_BR
sigepi.autor.atividadeFREITAS, ANDERSON Z. DE:880:920:Npt_BR
sigepi.autor.atividadeMATHOR, MONICA B.:209:240:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
25540.pdf
Tamanho:
92.71 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: