Uncertainty Estimation of Metals and Semimetals Determination in Wastewater by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES)
| dc.contributor.author | MARQUES, J.R. | |
| dc.contributor.author | VILLA-SOARES, S.M. | |
| dc.contributor.author | STELLATO, T.B. | |
| dc.contributor.author | SILVA, T.B.S.C. | |
| dc.contributor.author | FAUSTINO, M.G. | |
| dc.contributor.author | MONTEIRO, L.R. | |
| dc.contributor.author | PIRES, M.A.F. | |
| dc.contributor.author | COTRIM, M.E.B. | |
| dc.coverage | Internacional | pt_BR |
| dc.creator.evento | BRAZILIAN CONGRESS ON METROLOGY, 8th | pt_BR |
| dc.date.accessioned | 2017-03-20T12:34:03Z | |
| dc.date.available | 2017-03-20T12:34:03Z | |
| dc.date.evento | 29 de novembro - 04 de dezembro, 2015 | pt_BR |
| dc.description.abstract | The measurement uncertainty is a parameter that represents the dispersion of the results obtained by a method of analysis. The estimation of measurement uncertainty in the determination of metals and semimetals is important to compare the results with limits defined by environmental legislation and conclude if the analytes are meeting the requirements. Therefore, the aim of this paper is present all the steps followed to estimate the uncertainty of the determination of amount of metals and semimetals in wastewater by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES). Measurement uncertainty obtained was between 4.6 and 12.2% in the concentration range of mg.L-1. | pt_BR |
| dc.format.extent | 1-5 | pt_BR |
| dc.identifier.citation | MARQUES, J.R.; VILLA-SOARES, S.M.; STELLATO, T.B.; SILVA, T.B.S.C.; FAUSTINO, M.G.; MONTEIRO, L.R.; PIRES, M.A.F.; COTRIM, M.E.B. Uncertainty Estimation of Metals and Semimetals Determination in Wastewater by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES). In: BRAZILIAN CONGRESS ON METROLOGY, 8th, 29 de novembro - 04 de dezembro, 2015, Bento Gonçalves, RS. <b>Proceedings...</b> p. 1-5. Disponível em: http://repositorio.ipen.br/handle/123456789/27219. | |
| dc.identifier.orcid | https://orcid.org/0000-0002-6462-4758 | |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/27219 | |
| dc.local.evento | Bento Gonçalves, RS | pt_BR |
| dc.rights | openAccess | pt_BR |
| dc.source | Journal of Physics: Conference Series, v. 733, 2016 | pt_BR |
| dc.subject | abundance | |
| dc.subject | comparative evaluations | |
| dc.subject | concentration ratio | |
| dc.subject | data covariances | |
| dc.subject | emission spectroscopy | |
| dc.subject | metals | |
| dc.subject | semimetals | |
| dc.subject | waste water | |
| dc.title | Uncertainty Estimation of Metals and Semimetals Determination in Wastewater by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) | pt_BR |
| dc.type | Texto completo de evento | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | THAMIRIS BRANDINO STELLATO | |
| ipen.autor | MAINARA GENEROSO FAUSTINO | |
| ipen.autor | MARYCEL ELENA BARBOZA COTRIM | |
| ipen.autor | MARIA APARECIDA FAUSTINO PIRES | |
| ipen.autor | LUCILENA REBELO MONTEIRO | |
| ipen.autor | TATIANE BERNARDINO DE SEIXAS CARVALHO DA SILVA | |
| ipen.autor | SABRINA MOURA VILLA SOARES | |
| ipen.autor | JOSE RONALDO DE OLIVEIRA MARQUES | |
| ipen.codigoautor | 11433 | |
| ipen.codigoautor | 9776 | |
| ipen.codigoautor | 515 | |
| ipen.codigoautor | 1327 | |
| ipen.codigoautor | 2213 | |
| ipen.codigoautor | 11431 | |
| ipen.codigoautor | 10916 | |
| ipen.codigoautor | 1515 | |
| ipen.contributor.ipenauthor | THAMIRIS BRANDINO STELLATO | |
| ipen.contributor.ipenauthor | MAINARA GENEROSO FAUSTINO | |
| ipen.contributor.ipenauthor | MARYCEL ELENA BARBOZA COTRIM | |
| ipen.contributor.ipenauthor | MARIA APARECIDA FAUSTINO PIRES | |
| ipen.contributor.ipenauthor | LUCILENA REBELO MONTEIRO | |
| ipen.contributor.ipenauthor | TATIANE BERNARDINO DE SEIXAS CARVALHO DA SILVA | |
| ipen.contributor.ipenauthor | SABRINA MOURA VILLA SOARES | |
| ipen.contributor.ipenauthor | JOSE RONALDO DE OLIVEIRA MARQUES | |
| ipen.date.recebimento | 17-03 | pt_BR |
| ipen.event.datapadronizada | 2016 | pt_BR |
| ipen.identifier.ipendoc | 23574 | pt_BR |
| ipen.notas.internas | Proceedings | pt_BR |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | 515ad786-6dab-4a2c-9567-7226a1401f98 | |
| relation.isAuthorOfPublication | ca5275fc-c9df-452d-8341-f86f0fcd2e42 | |
| relation.isAuthorOfPublication | cc013e19-0c8e-4f8c-845f-f2ff7471b78a | |
| relation.isAuthorOfPublication | 2254b498-a2dd-4f3f-a64d-d0d6e8a3acdf | |
| relation.isAuthorOfPublication | 3bec81f8-3e1f-442e-8b83-84dc9e608dc7 | |
| relation.isAuthorOfPublication | 44feec13-0b42-4f54-8a90-79162bad4146 | |
| relation.isAuthorOfPublication | ef3d3284-f360-4f78-94b4-00b38d1e27bb | |
| relation.isAuthorOfPublication | da553885-c30c-4941-b75e-95c127e94f43 | |
| relation.isAuthorOfPublication.latestForDiscovery | da553885-c30c-4941-b75e-95c127e94f43 | |
| sigepi.autor.atividade | MARQUES, J.R.:1515:-1:S | pt_BR |
| sigepi.autor.atividade | VILLA-SOARES, S.M.:10916:-1:N | pt_BR |
| sigepi.autor.atividade | STELLATO, T.B.:11433:510:S | pt_BR |
| sigepi.autor.atividade | SILVA, T.B.S.C.:11431:510:N | pt_BR |
| sigepi.autor.atividade | FAUSTINO, M.G.:9776:510:N | pt_BR |
| sigepi.autor.atividade | MONTEIRO, L.R.:2213:-1:N | pt_BR |
| sigepi.autor.atividade | PIRES, M.A.F.:1327:-1:N | pt_BR |
| sigepi.autor.atividade | COTRIM, M.E.B.:515:-1:N | pt_BR |