Pellets of oyster shell for high dose dosimetry
| dc.contributor.author | VILA, GUSTAVO B. | pt_BR |
| dc.contributor.author | CALDAS, LINDA V.E. | pt_BR |
| dc.coverage | Internacional | pt_BR |
| dc.creator.evento | EUROPEAN IRPA CONGRESS, 2rd - RADIATION PROTECTION - SCIENCE, SAFETY AND SECURITY | pt_BR |
| dc.date.accessioned | 2014-11-17T18:38:52Z | pt_BR |
| dc.date.accessioned | 2014-11-18T18:59:26Z | pt_BR |
| dc.date.accessioned | 2015-04-02T04:05:01Z | |
| dc.date.available | 2014-11-17T18:38:52Z | pt_BR |
| dc.date.available | 2014-11-18T18:59:26Z | pt_BR |
| dc.date.available | 2015-04-02T04:05:01Z | |
| dc.date.evento | June 14-16, 2010 | pt_BR |
| dc.description.abstract | Several kinds of silicates have demonstrated their usefulness as radiation detectors for high dose dosimetry. In this work, oyster shell powdered samples were tested for high doses using the thermoluminescence (TL) and thermally stimulated exoelectron emission (TSEE) techniques. Pellets were obtained from the oyster shell powder mixed with Teflon followed by a sinterization process of thermal treatments of 300°C/30min and 400°C/1.5h. The TL glow curves showed two peaks at 110 and 220°C, and in the TSEE case, two peaks at 120 and 180°C. The main dosimetric properties were studied: reproducibility, dose-response curves and lower detection limits. The preliminary results showed the potential use of the studied material as radiation detectors. | |
| dc.identifier.citation | VILA, GUSTAVO B.; CALDAS, LINDA V.E. Pellets of oyster shell for high dose dosimetry: preliminary study. In: EUROPEAN IRPA CONGRESS, 2rd - RADIATION PROTECTION - SCIENCE, SAFETY AND SECURITY, June 14-16, 2010, Helsinki, Finland. <b>Proceedings...</b> Disponível em: http://repositorio.ipen.br/handle/123456789/17836. | |
| dc.identifier.orcid | https://orcid.org/0000-0002-7362-2455 | |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/17836 | pt_BR |
| dc.local.evento | Helsinki, Finland | pt_BR |
| dc.rights | openAccess | pt_BR |
| dc.subject | pellets | pt_BR |
| dc.subject | silicates | pt_BR |
| dc.subject | teflon | pt_BR |
| dc.subject | sintering | pt_BR |
| dc.subject | heat treatments | pt_BR |
| dc.subject | radiation detectors | pt_BR |
| dc.subject | thermoluminescence | pt_BR |
| dc.subject | exoelectron dosemeters | pt_BR |
| dc.title | Pellets of oyster shell for high dose dosimetry | pt_BR |
| dc.type | Texto completo de evento | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | LINDA V. E. CALDAS | |
| ipen.autor | GUSTAVO BARRETTO VILA | |
| ipen.codigoautor | 1495 | |
| ipen.codigoautor | 7969 | |
| ipen.contributor.ipenauthor | LINDA V. E. CALDAS | |
| ipen.contributor.ipenauthor | GUSTAVO BARRETTO VILA | |
| ipen.date.recebimento | 10-11 | pt_BR |
| ipen.event.datapadronizada | 2010 | pt_BR |
| ipen.identifier.ipendoc | 15756 | pt_BR |
| ipen.notas.internas | Proceedings | pt_BR |
| ipen.subtitulo | preliminary study | |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | 7f46d4f4-dfd6-4485-a767-10df5b4f4f13 | |
| relation.isAuthorOfPublication | ad944991-5892-47c7-9897-4a38d1031ee1 | |
| relation.isAuthorOfPublication.latestForDiscovery | ad944991-5892-47c7-9897-4a38d1031ee1 | |
| sigepi.autor.atividade | VILA, GUSTAVO B.:7969:-1:S | pt_BR |
| sigepi.autor.atividade | CALDAS, LINDA V.E.:1495:330:N | pt_BR |
Pacote Original