Detector efficiency calibration for extended gamma-ray sources

dc.contributor.authorSANTOS, ROBERTO M. dospt_BR
dc.contributor.authorGENEZINI, FREDERICO A.pt_BR
dc.contributor.authorZAHN, GUILHERME S.pt_BR
dc.contributor.editorVANIN, VITO R.pt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoBRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 33rdpt_BR
dc.date.accessioned2014-11-17T18:39:22Zpt_BR
dc.date.accessioned2014-11-18T19:00:15Zpt_BR
dc.date.accessioned2015-04-02T03:55:29Z
dc.date.available2014-11-17T18:39:22Zpt_BR
dc.date.available2014-11-18T19:00:15Zpt_BR
dc.date.available2015-04-02T03:55:29Z
dc.date.eventoSeptember 7-11, 2010pt_BR
dc.description.abstractA new method for the efficiency calibration of Ge detectors efficiency in measurements with large sources is proposed. To check the reliability of the method, a standard large source was produced and the results are compared to the ones obtained using the proposed method. The preliminary results point to the needs of increasing statistical measurements to allow for a more accurate evaluation of the method.
dc.format.extent220-230pt_BR
dc.identifier.citationSANTOS, ROBERTO M. dos; GENEZINI, FREDERICO A.; ZAHN, GUILHERME S. Detector efficiency calibration for extended gamma-ray sources. In: VANIN, VITO R. (ed.). In: BRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 33rd, September 7-11, 2010, Campos do Jordão, SP. <b>Proceedings...</b> p. 220-230. DOI: <a href="https://dx.doi.org/10.1063/1.3608961">10.1063/1.3608961</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/17881.
dc.identifier.doi10.1063/1.3608961
dc.identifier.orcidhttps://orcid.org/0000-0003-3237-8588
dc.identifier.orcidhttps://orcid.org/0000-0002-6318-6805
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/17881pt_BR
dc.local.eventoCampos do Jordão, SPpt_BR
dc.publisherAmerican Institute of Physicspt_BR
dc.rightsopenAccesspt_BR
dc.subjectcalibrationpt_BR
dc.subjectcalibration standardspt_BR
dc.subjectefficiencypt_BR
dc.subjectgamma detectionpt_BR
dc.subjectge semiconductor detectorspt_BR
dc.subjectmonte carlo methodpt_BR
dc.titleDetector efficiency calibration for extended gamma-ray sourcespt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorROBERTO MANUEL DOS SANTOS
ipen.autorGUILHERME SOARES ZAHN
ipen.autorFREDERICO ANTONIO GENEZINI
ipen.codigoautor8664
ipen.codigoautor950
ipen.codigoautor2045
ipen.contributor.ipenauthorROBERTO MANUEL DOS SANTOS
ipen.contributor.ipenauthorGUILHERME SOARES ZAHN
ipen.contributor.ipenauthorFREDERICO ANTONIO GENEZINI
ipen.date.recebimento13-04pt_BR
ipen.event.datapadronizada2010pt_BR
ipen.identifier.ipendoc18892pt_BR
ipen.notas.internasProceedingspt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication984bb08b-c38a-4e69-baf0-88f9b5cf60ee
relation.isAuthorOfPublicationde99ffee-d830-4bea-aeeb-e8f3ccc34921
relation.isAuthorOfPublication0c41d307-45a9-47c4-8281-5aa9ed46e6a4
relation.isAuthorOfPublication.latestForDiscovery984bb08b-c38a-4e69-baf0-88f9b5cf60ee
sigepi.autor.atividadeSANTOS, ROBERTO M. DOS:8664:310:Spt_BR
sigepi.autor.atividadeGENEZINI, FREDERICO A.:2045:310:Npt_BR
sigepi.autor.atividadeZAHN, GUILHERME S.:950:310:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
18892.pdf
Tamanho:
147.16 KB
Formato:
Adobe Portable Document Format

Coleções