Calibration of two sup(90)Sr+sup(90)Y dermatological applicators

dc.contributor.authorANTONIO, PATRICIA L.pt_BR
dc.contributor.authorCALDAS, LINDA V.E.pt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, 12thpt_BR
dc.date.accessioned2014-11-17T18:02:39Zpt_BR
dc.date.accessioned2014-11-18T18:14:55Zpt_BR
dc.date.accessioned2015-04-02T03:38:17Z
dc.date.available2014-11-17T18:02:39Zpt_BR
dc.date.available2014-11-18T18:14:55Zpt_BR
dc.date.available2015-04-02T03:38:17Z
dc.date.eventoOctober 19-24, 2008pt_BR
dc.description.abstractThe 90Sr+90Y applicators need to be periodically calibrated, but in Brazil the service it not offered yet. The recommended method for the calibration of this kind of applicators is the use of extrapolation chambers. An alternative method for the calibration of clinical applicators is the use of thermoluminescent dosimeters. A dosimetric method of these applicators was already developed at Instituto de Pesquisas Energéticas e Nucleares (IPEN) and several types of thermoluminescent dosimeters were studied in previous works. The aim of this work was the application of this method to calibrate two dermatological applicators. Thin CaSO4:Dy pellets, with and without 10% of graphite were utilized. The reproducibility of these pellets was studied, and calibration curves were obtained using a standard applicator calibrated at the National Institute of Standards and Technology (NIST), USA. Both applicators showed similar results. The TL materials tested showed usefulness for dosimetry and calibration of this kind of applicators.
dc.event.siglaIRPA12pt_BR
dc.identifier.citationANTONIO, PATRICIA L.; CALDAS, LINDA V.E. Calibration of two sup(90)Sr+sup(90)Y dermatological applicators. In: INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, 12th, October 19-24, 2008, Buenos Aires, Argentina. <b>Proceedings...</b> Disponível em: http://repositorio.ipen.br/handle/123456789/15930.
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/15930pt_BR
dc.local.eventoBuenos Aires, Argentinapt_BR
dc.rightsopenAccesspt_BR
dc.subjectstrontium 90pt_BR
dc.subjectyttrium 90pt_BR
dc.subjectcalibrationpt_BR
dc.subjectextrapolation chamberspt_BR
dc.subjectthermoluminescent dosimetrypt_BR
dc.subjectbeta detectionpt_BR
dc.subjectbrachytherapypt_BR
dc.titleCalibration of two sup(90)Sr+sup(90)Y dermatological applicatorspt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorLINDA V. E. CALDAS
ipen.autorPATRICIA DE LARA ANTONIO
ipen.codigoautor1495
ipen.codigoautor6585
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.contributor.ipenauthorPATRICIA DE LARA ANTONIO
ipen.date.recebimento09-03pt_BR
ipen.event.datapadronizada2008pt_BR
ipen.identifier.ipendoc13381pt_BR
ipen.notas.internasProceedingspt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublication5ea4ca8b-8415-4439-81d2-6fe0d6debd42
relation.isAuthorOfPublication.latestForDiscovery5ea4ca8b-8415-4439-81d2-6fe0d6debd42
sigepi.autor.atividadeANTONIO, PATRICIA L.:6585:330:Spt_BR
sigepi.autor.atividadeCALDAS, LINDA V.E.:1495:330:Npt_BR