Reconstructed image quality analysis of an industrial instant non-scanning tomography system with different types of collimators by the Monte Carlo Simulation

dc.contributor.authorVELO, ALEXANDRE F.
dc.contributor.authorCARVALHO, DIEGO V.
dc.contributor.authorALVAREZ, ALEXANDRE G.
dc.contributor.authorHAMADA, MARGARIDA M.
dc.contributor.authorMESQUITA, CARLOS H.
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL NUCLEAR ATLANTIC CONFERENCEpt_BR
dc.date.accessioned2018-01-15T09:49:56Z
dc.date.available2018-01-15T09:49:56Z
dc.date.eventoOctober 22-27, 2017pt_BR
dc.description.abstractThe greatest impact of the tomography technology application currently occurs in medicine. The great success of medical tomography is due to the human body presents reasonably standardized dimensions with wellestablished chemical composition. Generally, these favorable conditions are not found in large industrial objects. In the industry there is much interest in using the information of the tomograph in order to know the interior of: (i) manufactured industrial objects or (ii) machines and their means of production. In these cases, the purpose of the tomograph is to: (a) control the quality of the final product and (b) optimize production, contributing to the pilot phase of the projects and analyzing the quality of the means of production. In different industrial processes, e. g. in chemical reactors and distillation columns, the phenomena related to multiphase processes are usually fast, requiring high temporal resolution of the computed tomography (CT) data acquisition. In this context, Instant non-scanning tomograph and fifth generation tomograph meets these requirements. An instant nonscanning tomography system is being developed at the IPEN/CNEN. In this work, in order to optimize the system, this tomograph comprised different collimators was simulated, with Monte Carlo method using the MCNP4C. The image quality was evaluated with Matlab® 2013b, by analysis of the following parameters: contrast to noise (CNR), root mean square ratio (RMSE), signal to noise ratio (SNR) and the spatial resolution by the Modulation Transfer Function (MTF(f)), to analyze which collimator fits better to the instant nonscanning tomography. It was simulated three situations; (i) with no collimator; (ii) ?25 mm x 50 mm cylindrical collimator with a septum of ø5.0 mm x 50 mm; (iii) ø25mm x 50 mm cylindrical collimator with a slit septum of 24 mm x 5.0 mm x 50 mm.pt_BR
dc.event.siglaINACpt_BR
dc.identifier.citationVELO, ALEXANDRE F.; CARVALHO, DIEGO V.; ALVAREZ, ALEXANDRE G.; HAMADA, MARGARIDA M.; MESQUITA, CARLOS H. Reconstructed image quality analysis of an industrial instant non-scanning tomography system with different types of collimators by the Monte Carlo Simulation. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. <b>Proceedings...</b> Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017. Disponível em: http://repositorio.ipen.br/handle/123456789/28309.
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/28309
dc.localRio de Janeiro, RJpt_BR
dc.local.eventoBelo Horizonte, MGpt_BR
dc.publisherAssociação Brasileira de Energia Nuclearpt_BR
dc.rightsopenAccesspt_BR
dc.subjectcollimators
dc.subjectcomputerized tomography
dc.subjectimage processing
dc.subjectmonte carlo method
dc.subjectquality assurance
dc.subjectquality management
dc.subjectshielding
dc.subjectsignal-to-noise ratio
dc.subjectspatial resolution
dc.titleReconstructed image quality analysis of an industrial instant non-scanning tomography system with different types of collimators by the Monte Carlo Simulationpt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorALEXANDRE GIMENEZ ALVAREZ
ipen.autorCARLOS HENRIQUE DE MESQUITA
ipen.autorMARGARIDA MIZUE HAMADA
ipen.autorDIEGO VERGAÇAS DE SOUSA CARVALHO
ipen.autorALEXANDRE FRANÇA VELO
ipen.codigoautor14665
ipen.codigoautor1149
ipen.codigoautor1476
ipen.codigoautor8640
ipen.codigoautor12736
ipen.contributor.ipenauthorALEXANDRE GIMENEZ ALVAREZ
ipen.contributor.ipenauthorCARLOS HENRIQUE DE MESQUITA
ipen.contributor.ipenauthorMARGARIDA MIZUE HAMADA
ipen.contributor.ipenauthorDIEGO VERGAÇAS DE SOUSA CARVALHO
ipen.contributor.ipenauthorALEXANDRE FRANÇA VELO
ipen.date.recebimento18-01pt_BR
ipen.event.datapadronizada2017pt_BR
ipen.identifier.ipendoc24144pt_BR
ipen.notas.internasProceedingspt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublicatione6fc5ff0-9297-486c-99e8-bf64ec2fc502
relation.isAuthorOfPublication20d22e5e-a0d1-4286-b4d9-20e5ac53cb51
relation.isAuthorOfPublication74139eee-5dbd-4dfd-b672-89cb56c5cce5
relation.isAuthorOfPublication507a0df0-1daa-4be5-a631-a20589277042
relation.isAuthorOfPublicationb295ccf7-5904-42e8-aa60-0d9fd45e1100
relation.isAuthorOfPublication.latestForDiscoveryb295ccf7-5904-42e8-aa60-0d9fd45e1100
sigepi.autor.atividadeVELO, ALEXANDRE F.:12736:240:Spt_BR
sigepi.autor.atividadeCARVALHO, DIEGO V.:8640:240:Npt_BR
sigepi.autor.atividadeALVAREZ, ALEXANDRE G.:14665:-1:Npt_BR
sigepi.autor.atividadeHAMADA, MARGARIDA M.:1476:240:Npt_BR
sigepi.autor.atividadeMESQUITA, CARLOS H.:1149:240:Npt_BR
Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
24144.pdf
Tamanho:
571.94 KB
Formato:
Adobe Portable Document Format
Descrição:
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Coleções