Characterization of a parallel plate ionization chamber of the quality control of clinica applicators
| dc.contributor.author | ANTONIO, P.L. | pt_BR |
| dc.contributor.author | CALDAS, L.V.E. | pt_BR |
| dc.coverage | Internacional | pt_BR |
| dc.creator.evento | INTERNATIONAL SYMPOSIUM ON STANDARDS, APPLICATIONS AND QUALITY ASSURANCE IN MEDICAL RADIATION DOSIMETRY | pt_BR |
| dc.date.accessioned | 2014-11-17T18:40:14Z | pt_BR |
| dc.date.accessioned | 2014-11-18T19:03:25Z | pt_BR |
| dc.date.accessioned | 2015-04-02T06:21:29Z | |
| dc.date.available | 2014-11-17T18:40:14Z | pt_BR |
| dc.date.available | 2014-11-18T19:03:25Z | pt_BR |
| dc.date.available | 2015-04-02T06:21:29Z | |
| dc.date.evento | November 9-12, 2010 | pt_BR |
| dc.description.abstract | A parallel plate ionization chamber, developed at the Calibration Laboratory of IPEN (LCI), was utilized with the objective to verify the possibility of its application in the quality control program of 90Sr+90Y clinical applicators at clinics and hospitals that perform betatherapy procedures.The characterization of this ionization chamber was realized using a reference clinical applicator. The results of this work showed that this kind of ionization chamber may be useful in quality control programs of 90Sr+90Y sources, including the procedure of calibration of these sources. | |
| dc.identifier.citation | ANTONIO, P.L.; CALDAS, L.V.E. Characterization of a parallel plate ionization chamber of the quality control of clinica applicators. In: INTERNATIONAL SYMPOSIUM ON STANDARDS, APPLICATIONS AND QUALITY ASSURANCE IN MEDICAL RADIATION DOSIMETRY, November 9-12, 2010, Vienna, Austria. <b>Proceedings...</b> Disponível em: http://repositorio.ipen.br/handle/123456789/17949. | |
| dc.identifier.orcid | https://orcid.org/0000-0002-7362-2455 | |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/17949 | pt_BR |
| dc.local.evento | Vienna, Austria | pt_BR |
| dc.rights | openAccess | pt_BR |
| dc.subject | brachytherapy | pt_BR |
| dc.subject | calibration | pt_BR |
| dc.subject | dosimetry | pt_BR |
| dc.subject | electron beams | pt_BR |
| dc.subject | extrapolation chambers | pt_BR |
| dc.subject | quality control | pt_BR |
| dc.subject | radiation doses | pt_BR |
| dc.subject | strontium 90 | pt_BR |
| dc.subject | yttrium 90 | pt_BR |
| dc.title | Characterization of a parallel plate ionization chamber of the quality control of clinica applicators | pt_BR |
| dc.type | Texto completo de evento | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | LINDA V. E. CALDAS | |
| ipen.autor | PATRICIA DE LARA ANTONIO | |
| ipen.codigoautor | 1495 | |
| ipen.codigoautor | 6585 | |
| ipen.contributor.ipenauthor | LINDA V. E. CALDAS | |
| ipen.contributor.ipenauthor | PATRICIA DE LARA ANTONIO | |
| ipen.date.recebimento | 10-12 | pt_BR |
| ipen.event.datapadronizada | 2010 | pt_BR |
| ipen.identifier.ipendoc | 15974 | pt_BR |
| ipen.notas.internas | Proceedings | pt_BR |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | 7f46d4f4-dfd6-4485-a767-10df5b4f4f13 | |
| relation.isAuthorOfPublication | 5ea4ca8b-8415-4439-81d2-6fe0d6debd42 | |
| relation.isAuthorOfPublication.latestForDiscovery | 5ea4ca8b-8415-4439-81d2-6fe0d6debd42 | |
| sigepi.autor.atividade | ANTONIO, P.L.:6585:330:S | pt_BR |
| sigepi.autor.atividade | CALDAS, L.V.E.:1495:330:N | pt_BR |
Pacote Original