Experimental and Monte Carlo evaluation of an ionization chamber in a 60Co beam
| dc.contributor.author | PERINI, A.P. | |
| dc.contributor.author | NEVES, L.P. | |
| dc.contributor.author | SANTOS, W.S. | |
| dc.contributor.author | CALDAS, L.V.E. | |
| dc.coverage | Internacional | pt_BR |
| dc.creator.evento | BRAZILIAN CONGRESS ON METROLOGY, 8th | pt_BR |
| dc.date.accessioned | 2017-03-20T13:49:14Z | |
| dc.date.available | 2017-03-20T13:49:14Z | |
| dc.date.evento | 29 de novembro - 04 de dezembro, 2015 | pt_BR |
| dc.description.abstract | Recently a special parallel-plate ionization chamber was developed and characterized at the Instituto de Pesquisas Energ eticas e Nucleares. The operational tests presented results within the recommended limits. In order to determine the in uence of some components of the ionization chamber on its response, Monte Carlo simulations were carried out. The experimental and simulation results pointed out that the dosimeter evaluated in the present work has favorable properties to be applied to 60Co dosimetry at calibration laboratories. | pt_BR |
| dc.format.extent | 1-5 | pt_BR |
| dc.identifier.citation | PERINI, A.P.; NEVES, L.P.; SANTOS, W.S.; CALDAS, L.V.E. Experimental and Monte Carlo evaluation of an ionization chamber in a 60Co beam. In: BRAZILIAN CONGRESS ON METROLOGY, 8th, 29 de novembro - 04 de dezembro, 2015, Bento Gonçalves, RS. <b>Proceedings...</b> p. 1-5. Disponível em: http://repositorio.ipen.br/handle/123456789/27220. | |
| dc.identifier.orcid | https://orcid.org/0000-0002-7362-2455 | |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/27220 | |
| dc.local.evento | Bento Gonçalves, RS | pt_BR |
| dc.rights | openAccess | pt_BR |
| dc.source | Journal of Physics: Conference Series, v. 733, 2016 | pt_BR |
| dc.subject | monte carlo method | |
| dc.subject | ionization chambers | |
| dc.subject | cobalt 60 | |
| dc.subject | experimental data | |
| dc.subject | dosimetry | |
| dc.subject | calibration standards | |
| dc.title | Experimental and Monte Carlo evaluation of an ionization chamber in a 60Co beam | pt_BR |
| dc.type | Texto completo de evento | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | LINDA V. E. CALDAS | |
| ipen.autor | WAGNER SOARES DOS SANTOS | |
| ipen.codigoautor | 1495 | |
| ipen.codigoautor | 2616 | |
| ipen.contributor.ipenauthor | LINDA V. E. CALDAS | |
| ipen.contributor.ipenauthor | WAGNER SOARES DOS SANTOS | |
| ipen.date.recebimento | 17-03 | pt_BR |
| ipen.event.datapadronizada | 2016 | pt_BR |
| ipen.identifier.ipendoc | 23534 | pt_BR |
| ipen.notas.internas | Proceedings | pt_BR |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | 7f46d4f4-dfd6-4485-a767-10df5b4f4f13 | |
| relation.isAuthorOfPublication | fe2d15f6-bc48-4f38-8e0f-7904b0bf3ef9 | |
| relation.isAuthorOfPublication.latestForDiscovery | fe2d15f6-bc48-4f38-8e0f-7904b0bf3ef9 | |
| sigepi.autor.atividade | SANTOS, W.S.:2616:-1:N | pt_BR |
| sigepi.autor.atividade | CALDAS, L.V.E.:1495:-1:N | pt_BR |