Determination of molybdenum ablation threshold for ultrashiort laser pulses in atmosphere and vacuum using the diagonal scan technique
dc.contributor.author | SAMAD, RICARDO E. | pt_BR |
dc.contributor.author | VIDAL, JOSE T. | pt_BR |
dc.contributor.author | ROSSI, WAGNER de | pt_BR |
dc.contributor.author | VIEIRA JUNIOR, NILSON D. | pt_BR |
dc.coverage | Internacional | pt_BR |
dc.creator.evento | LATIN AMERICA OPTICS AND PHOTONICS CONFERENCE | pt_BR |
dc.date.accessioned | 2014-11-17T18:38:27Z | pt_BR |
dc.date.accessioned | 2014-11-18T18:58:07Z | pt_BR |
dc.date.accessioned | 2015-04-02T04:39:43Z | |
dc.date.available | 2014-11-17T18:38:27Z | pt_BR |
dc.date.available | 2014-11-18T18:58:07Z | pt_BR |
dc.date.available | 2015-04-02T04:39:43Z | |
dc.date.evento | September 27-30, 2010 | pt_BR |
dc.description.abstract | We present the results of measuring metallic molybdenum ablation threshold in the 30 femtoseconds regime. The measurements were performed in atmosphere and vacuum, resulting in values equal to 1.6 TW/cm2 3.8 TW/cm2, respectively. This values difference can be credited to a plasma etching that helps the ablation in the atmosphere case. | |
dc.identifier.citation | SAMAD, RICARDO E.; VIDAL, JOSE T.; ROSSI, WAGNER de; VIEIRA JUNIOR, NILSON D. Determination of molybdenum ablation threshold for ultrashiort laser pulses in atmosphere and vacuum using the diagonal scan technique. In: LATIN AMERICA OPTICS AND PHOTONICS CONFERENCE, September 27-30, 2010, Recife, PE. <b>Proceedings...</b> DOI: <a href="https://dx.doi.org/10.1364/LAOP.2010.ThD3">10.1364/LAOP.2010.ThD3</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/17798. | |
dc.identifier.doi | 10.1364/LAOP.2010.ThD3 | |
dc.identifier.orcid | https://orcid.org/0000-0003-0092-9357 | |
dc.identifier.orcid | https://orcid.org/0000-0003-1371-7521 | |
dc.identifier.orcid | https://orcid.org/0000-0001-7762-8961 | |
dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/17798 | pt_BR |
dc.local.evento | Recife, PE | pt_BR |
dc.rights | openAccess | pt_BR |
dc.subject | ablation | pt_BR |
dc.subject | pulses | pt_BR |
dc.subject | breakdown | pt_BR |
dc.subject | lasers | |
dc.title | Determination of molybdenum ablation threshold for ultrashiort laser pulses in atmosphere and vacuum using the diagonal scan technique | pt_BR |
dc.type | Texto completo de evento | pt_BR |
dspace.entity.type | Publication | |
ipen.autor | NILSON DIAS VIEIRA JUNIOR | |
ipen.autor | WAGNER DE ROSSI | |
ipen.autor | JOSE TORT VIDAL | |
ipen.autor | RICARDO ELGUL SAMAD | |
ipen.codigoautor | 1582 | |
ipen.codigoautor | 73 | |
ipen.codigoautor | 181 | |
ipen.codigoautor | 909 | |
ipen.contributor.ipenauthor | NILSON DIAS VIEIRA JUNIOR | |
ipen.contributor.ipenauthor | WAGNER DE ROSSI | |
ipen.contributor.ipenauthor | JOSE TORT VIDAL | |
ipen.contributor.ipenauthor | RICARDO ELGUL SAMAD | |
ipen.date.recebimento | 10-08 | pt_BR |
ipen.event.datapadronizada | 2010 | pt_BR |
ipen.identifier.ipendoc | 15597 | pt_BR |
ipen.notas.internas | Proceedings | pt_BR |
ipen.type.genre | Artigo | |
relation.isAuthorOfPublication | b5e4f489-bfb7-4e48-ae3a-eced2bb93a16 | |
relation.isAuthorOfPublication | 4e856bd3-cb24-4e4f-902b-58fd9ddf811f | |
relation.isAuthorOfPublication | 710767b5-bbce-4cfc-9127-165a60d59994 | |
relation.isAuthorOfPublication | b9c43c0c-87a6-4ebd-92ff-2515c4ac1d34 | |
relation.isAuthorOfPublication.latestForDiscovery | b9c43c0c-87a6-4ebd-92ff-2515c4ac1d34 | |
sigepi.autor.atividade | SAMAD, RICARDO E.:909:930:S | pt_BR |
sigepi.autor.atividade | VIDAL, JOSE T.:181:920:N | pt_BR |
sigepi.autor.atividade | ROSSI, WAGNER DE:73:920:N | pt_BR |
sigepi.autor.atividade | VIEIRA JUNIOR, NILSON D.:1582:930:N | pt_BR |
Pacote Original
1 - 1 de 1