Study fricke gel dosimeter response for different gel quality

dc.contributor.authorCAVINATO, CHRISTIANNE C.pt_BR
dc.contributor.authorCAMPOS, LETICIA L.pt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL CONFERENCE ON DEFECTS IN INSULATING MATERIALS, 16thpt_BR
dc.date.accessioned2014-11-19T10:34:00Zpt_BR
dc.date.accessioned2014-11-19T14:06:00Zpt_BR
dc.date.accessioned2015-04-01T12:43:12Z
dc.date.available2014-11-19T10:34:00Zpt_BR
dc.date.available2014-11-19T14:06:00Zpt_BR
dc.date.available2015-04-01T12:43:12Z
dc.date.eventoAugust 24-29, 2008pt_BR
dc.description.abstractThe Fricke xylenol gel (FXG) dosimeter has been studied for application in radiotherapy because it is capable of to measure the spatial distribution of radiation doses. The dosimetry is based on the oxidation of ferrous (Fe2+) to ferric (Fe3+) ions radiation induced, related to the radiation dose. The gel material usually employed is the 300 Bloom gelatin, which is imported and very expensive in Brazil. Aiming to analyze the viability of to use a locally produced and low cost gel material, in this work the spectrophotometric responses of FXG solutions prepared using 270 Bloom gelatin commercially available and 300 Bloom gelatin imported were compared. The absorption spectra of solutions prepared with 5% by weight 270 and 300 Bloom gelatins non-irradiated and irradiated with 60Co gamma radiation in the dose range between 0.5 and 100 Gy were analysed, the dose-response curves were evaluated and the useful dose range was established. The obtained results indicate that the FXG solution prepared with 270 Bloom gelatin presents good performance, similar to that presented by the FXG solution prepared with 300 Bloom gelatin and its use can be recommended owing to the low cost and the availability in local market.
dc.event.siglaICDIM 2008pt_BR
dc.identifier.citationCAVINATO, CHRISTIANNE C.; CAMPOS, LETICIA L. Study fricke gel dosimeter response for different gel quality. In: INTERNATIONAL CONFERENCE ON DEFECTS IN INSULATING MATERIALS, 16th, August 24-29, 2008, Aracaju, SE. <b>Proceedings...</b> DOI: <a href="https://dx.doi.org/10.1088/1742-6596/249/1/012064">10.1088/1742-6596/249/1/012064</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/19226.
dc.identifier.doi10.1088/1742-6596/249/1/012064
dc.identifier.orcidhttps://orcid.org/0000-0001-7137-0613
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/19226pt_BR
dc.local.eventoAracaju, SEpt_BR
dc.rightsclosedAccesspt_BR
dc.sourceJournal of Physics: Conference Series, v. 249, p. 012064-1 - 012064-6, 2010
dc.subjectchemical dosemeterspt_BR
dc.subjectgelspt_BR
dc.subjectradiotherapypt_BR
dc.subjectradiation dose distributionspt_BR
dc.subjectiron ionspt_BR
dc.subjectgelatinpt_BR
dc.subjectspectrophotometrypt_BR
dc.subjectcost benefit analysispt_BR
dc.titleStudy fricke gel dosimeter response for different gel qualitypt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.autorCHRISTIANNE COBELLO CAVINATO
ipen.codigoautor1195
ipen.codigoautor3880
ipen.contributor.ipenauthorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.contributor.ipenauthorCHRISTIANNE COBELLO CAVINATO
ipen.date.recebimento09-03pt_BR
ipen.event.datapadronizada2008pt_BR
ipen.identifier.ipendoc13547pt_BR
ipen.notas.internasProceedingspt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublicationd4d34119-a6e6-4026-9a67-7b16d8b668da
relation.isAuthorOfPublication7a92997b-7fa4-4eb0-b8f0-7157368c2158
relation.isAuthorOfPublication.latestForDiscovery7a92997b-7fa4-4eb0-b8f0-7157368c2158
sigepi.autor.atividadeCAVINATO, CHRISTIANNE C.:3880:330:Spt_BR
sigepi.autor.atividadeCAMPOS, LETICIA L.:1195:330:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
13547.pdf
Tamanho:
750.82 KB
Formato:
Adobe Portable Document Format
Descrição:

Coleções