The influence of different 192Ir sources geometries to the energy deposition
| dc.contributor.author | SANTOS, W.S. | |
| dc.contributor.author | GONALVES, P.E. | |
| dc.contributor.author | BELINATO, W. | |
| dc.contributor.author | CALDAS, L.V.E. | |
| dc.contributor.author | PERINI, A.P. | |
| dc.contributor.author | NEVES, L.P. | |
| dc.coverage | Internacional | pt_BR |
| dc.creator.evento | BRAZILIAN CONGRESS ON METROLOGY, 8th | pt_BR |
| dc.date.accessioned | 2017-03-20T14:06:09Z | |
| dc.date.available | 2017-03-20T14:06:09Z | |
| dc.date.evento | 29 de novembro - 04 de dezembro, 2015 | pt_BR |
| dc.description.abstract | In this paper, various simpli cations of the HDR source Varian VariSource Classic model, in which 192Ir as a radionuclide is used, were compared. These simpli cations were carried out by Monte Carlo simulations, using the MCNPX 2.7.0 code. The different sources were compared through a distribution of energy deposition in a water phantom. Our results indicated that small simpli cations will present no in uence on the source response, and the removal of the entire capsule surrounding the radionuclide will present a difference of just 0.53% in the nal response. | pt_BR |
| dc.format.extent | 1-5 | pt_BR |
| dc.identifier.citation | SANTOS, W.S.; GONALVES, P.E.; BELINATO, W.; CALDAS, L.V.E.; PERINI, A.P.; NEVES, L.P. The influence of different 192Ir sources geometries to the energy deposition. In: BRAZILIAN CONGRESS ON METROLOGY, 8th, 29 de novembro - 04 de dezembro, 2015, Bento Gonçalves, RS. <b>Proceedings...</b> p. 1-5. Disponível em: http://repositorio.ipen.br/handle/123456789/27221. | |
| dc.identifier.orcid | https://orcid.org/0000-0002-7362-2455 | |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/27221 | |
| dc.local.evento | Bento Gonçalves, RS | pt_BR |
| dc.publisher | Bristol, UK: IOP Publishing | pt_BR |
| dc.rights | openAccess | pt_BR |
| dc.source | Journal of Physics: Conference Series, v. 733, 2016 | pt_BR |
| dc.subject | energy absorption | |
| dc.subject | iridium 192 | |
| dc.subject | monte carlo method | |
| dc.subject | dose rates | |
| dc.subject | radiotherapy | |
| dc.title | The influence of different 192Ir sources geometries to the energy deposition | pt_BR |
| dc.type | Texto completo de evento | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | GEORGES MIKHAEL NAMMOURA NETO | |
| ipen.autor | LINDA V. E. CALDAS | |
| ipen.autor | WAGNER SOARES DOS SANTOS | |
| ipen.codigoautor | 7503 | |
| ipen.codigoautor | 1495 | |
| ipen.codigoautor | 2616 | |
| ipen.contributor.ipenauthor | GEORGES MIKHAEL NAMMOURA NETO | |
| ipen.contributor.ipenauthor | LINDA V. E. CALDAS | |
| ipen.contributor.ipenauthor | WAGNER SOARES DOS SANTOS | |
| ipen.date.recebimento | 17-03 | pt_BR |
| ipen.event.datapadronizada | 2016 | pt_BR |
| ipen.identifier.ipendoc | 23580 | pt_BR |
| ipen.notas.internas | Proceedings | pt_BR |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | f9362f4a-6ea1-481c-bb7e-825cfcfb71cb | |
| relation.isAuthorOfPublication | 7f46d4f4-dfd6-4485-a767-10df5b4f4f13 | |
| relation.isAuthorOfPublication | fe2d15f6-bc48-4f38-8e0f-7904b0bf3ef9 | |
| relation.isAuthorOfPublication.latestForDiscovery | fe2d15f6-bc48-4f38-8e0f-7904b0bf3ef9 | |
| sigepi.autor.atividade | SANTOS, W.S.:2616:-1:S | pt_BR |
| sigepi.autor.atividade | CALDAS, L.V.E.:1495:-1:N | pt_BR |
| sigepi.autor.atividade | NEVES, L.P.:7503:-1:N | pt_BR |