In vitro thermographic measurement in pulpal chamber during diode laser bleaching

dc.contributor.authorGUIMARAES, J.G.A.pt_BR
dc.contributor.authorMIYAKAWA, W.pt_BR
dc.contributor.authorSTOLF, S.F.pt_BR
dc.contributor.authorSILVA, E.M.pt_BR
dc.contributor.authorZEZELL, D.M.pt_BR
dc.contributor.authorEDUARDO, C.P.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2022-02-16T13:38:40Z
dc.date.available2022-02-16T13:38:40Z
dc.date.issued2004pt_BR
dc.description.abstractThermographic was employed to determine the temperature rise in lower incisors pulpal chambers during diode laser bleaching. Two methods were used: a thermocouple for 72 teeth and a infrared (IR) thermographic camera for 36. Two bleaching agents, both 35% hydrogen peroxide- Whiteness HP (HP) and Hi Lite (HL) - were applied to the specimens buccal surfaces and irradiated with a diode laser (808 5nm), CW for 30s. Intensities tested were 21.W/cm2, 29.8W/cm2, 35.8W/cm2, 38.2W/cm2, 52.9W/cm2 e 63.7W/cm2. Means of the greatest temperature rises with the HL were statiscally lower than the HP (p<0.01). When HP was irradiated with 50.9W/cm² and 61.1W/cm², the temperature registered was over 5.5ºC, considered as the limit to avoid pulp damage. The IR thermacam analysis showed that, when the HP was used, the temperature rise in pulp chamber was similar to the target area on the buccal surface. Evaluation of tooth color was done using a VITAshade guide at baseline and at the end of the bleaching treatment. Both products proved to be efficient, however HP produced statiscally higher shade changes than HL (p<0.01). It can be concluded that the diode laser bleaching associated with the HP was safe when intensities below 50mW/cm2 were employed. Higher parameters can cause damage to pulp vitality of the lower incisors, fact that did not occurred with the HL gel. Both gels were efficacious to the bleaching technique proposed, but the HP showed better results.pt_BR
dc.format.extent94-94pt_BR
dc.identifier.citationGUIMARAES, J.G.A.; MIYAKAWA, W.; STOLF, S.F.; SILVA, E.M.; ZEZELL, D.M.; EDUARDO, C.P. In vitro thermographic measurement in pulpal chamber during diode laser bleaching. <b>Brazilian Dental Journal</b>, v. 15, p. 94-94, 2004. Special issue. Disponível em: http://repositorio.ipen.br/handle/123456789/32742.
dc.identifier.issn0103-6440pt_BR
dc.identifier.orcid0000-0001-7404-9606pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-7404-9606
dc.identifier.percentilfiSem Percentilpt_BR
dc.identifier.percentilfiCiteScoreSem Percentil CiteScorept_BR
dc.identifier.suplementoSpecial issuept_BR
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/32742
dc.identifier.vol15pt_BR
dc.relation.ispartofBrazilian Dental Journalpt_BR
dc.rightsopenAccesspt_BR
dc.sourceInternational Congress on Laser in Dentistry, 9th, July 21-24, 2004, São Paulo, SPpt_BR
dc.subjectdentin
dc.subjectteeth
dc.subjectbleaching
dc.subjectthermography
dc.subjecthydrogen peroxide
dc.subjectsemiconductor diodes
dc.subjectlasers
dc.titleIn vitro thermographic measurement in pulpal chamber during diode laser bleachingpt_BR
dc.typeResumos em periódicospt_BR
dspace.entity.typePublication
ipen.autorDENISE MARIA ZEZELL
ipen.codigoautor693
ipen.contributor.ipenauthorDENISE MARIA ZEZELL
ipen.date.recebimento22-02
ipen.identifier.fiSem F.I.pt_BR
ipen.identifier.fiCiteScoreSem CiteScorept_BR
ipen.identifier.ipendoc06281pt_BR
ipen.type.genreResumo
relation.isAuthorOfPublicationa565f8ad-3432-4891-98c0-a587f497db21
relation.isAuthorOfPublication.latestForDiscoverya565f8ad-3432-4891-98c0-a587f497db21
sigepi.autor.atividadeZEZELL, D.M.:693:920:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
06281.pdf
Tamanho:
747.63 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: