FRANCISCO DE ASSIS SOUZA

Projetos de Pesquisa
Unidades Organizacionais
Cargo

Resultados de Busca

Agora exibindo 1 - 10 de 16
  • Relatório IPEN-doc 29843
    Espectrometria gama dos Geradores de Vapor e da Tampa do Vaso do Reator depositados no DIGV (medidas preliminares)
    2023 - MEDEIROS, JOSE A.G. de; MORALLES, MAURICIO; SILVA JUNIOR, IREMAR A. da; YORIYAZ, HELIO; ZAHN, GUILHERME; GENEZINI, FREDERICO A.; SOUZA, FRANCISCO A.
    Este documento tem como objetivo apresentar os resultados das medidas preliminares de espectrometria gama dos Geradores de Vapor (GVs) e da Tampa do Vaso do Reator (TVR), realizadas entre os dias 02 e 10 de fevereiro de 2023. Estes equipamentos foram removidos de Angra 1 em 2009 e 2013, respectivamente, e se encontram no Depósito Inicial dos Geradores de Vapor (DIGV) no sítio da Central Nuclear Almirante Álvaro Alberto (CNAAA). As medidas de espectrometria gama buscam possibilitar a avaliação do inventário dos radionuclídeos gama emissores presentes nestas estruturas, mais particularmente daqueles a serem utilizados como radionuclídeos chaves na proposição das razões de concentração de atividade. O inventário dos radionuclídeos chaves, associado aos dados das razões de concentração de atividade de outros radionuclídeos presentes em amostras representativas dos GVs e da TVR, possibilitará a proposição de um inventário radioisotópico estendido dessas estruturas. Este documento apresenta também a medida de mapeamento dosimétrico dos GVs. Essa atividade visa a apresentação de informações complementares àquelas disponibilizadas pela atividade de espectrometria gama na avaliação do inventário dos radionuclídeos gama emissores. A apresentação deste documento atende o item 8.4.2 do Plano de Trabalho, que inclui a "Realização e apresentação dos resultados de espectrometria gama dos Geradores de Vapor e da Tampa do Vaso do Reator" do Acordo de Pesquisa e Desenvolvimento (Ativo Isotópico - Fase B) ,celebrado entre a Eletronuclear (ETN) e o Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP).
  • Relatório IPEN-doc 29644
    Procedimentos para espectroscopia gama dos Geradores de Vapor e da Tampa do Vaso do Reator depositados no DIGV
    2023 - MEDEIROS, JOSE A.G. de; SOUZA, FRANCISCO de A.; GENEZINI, FREDERICO A.; ZAHN, GUILHERME S.; YORIYAZ, HELIO; SILVA JUNIOR, IREMAR A. da; MORALLES, MAURICIO
    Este documento tem como objetivo apresentar um conjunto de procedimentos para a realização das medidas de espectroscopia gama nos Geradores de Vapor (GVs) e da Tampa do Vaso do Reator (TVR), removidos de Angra 1 , respectivamente, em 2009 e 2013, e que se encontram no Depósito Inicial dos Geradores de Vapor (DIGV) no sítio da Central Nuclear Almirante Álvaro Alberto (CNAAA). As medidas de espectrometria gama visam possibilitar a avaliação do inventário dos radioisótopos gama emissores dessas estruturas. Esse inventário, associado aos dados de concentração de atividade dos radioisótopos presentes em amostras representativas dos GVs e da TVR, possibilitará a proposição de um inventário radioisotópico estendido dessas estruturas. Adicionalmente, este trabalho apresenta também a proposição das atividades de mapeamento dosimétrico dos GVs e da TVR, atividades que devem ser desempenhadas simultaneamente às atividades de espectrometria. A apresentação deste documento visa atender ao cumprimento da atividade 8.3.4. “Planejamento da espectroscopia gama dos Geradores de Vapor e da Tampa do Vaso do Reator” do plano de trabalho, anexo ao acordo de parceria tecnológica existente entre o IPEN, a Eletronuclear e a Fundep.
  • Artigo IPEN-doc 29506
    Development of a fast simulator for GEM-based neutron detectors
    2022 - SANTOS, R.F. dos; MUNHOZ, M.G.; MORALLES, M.; SERRA FILHO, L.A.; BREGANT, M.; SOUZA, F.A.
    Gas Electron Multiplier (GEM)-based detectors using a layer of 10B as a neutron converter is becoming popular for thermal neutron detection. A common strategy to simulate this kind of detector is based on two frameworks: Geant4 and Gar eld++. The rst one provides the simulation of the nuclear interaction between neutrons and the 10B layer, while the second allows the simulation of the interaction of the reaction products with the detector gas leading to the ionization and excitation of the gas molecules. Given the high ionizing power of these nuclear reaction products, a full simulation is very time consuming and must be optimized to become viable. In this work, we present a strategy to develop a fast simulator based on these two frameworks that will allow us to generate enough data for a proper evaluation of the expected performance and optimization of this kind of detector. We will show the rst results obtained with this tool concentrating on its validation and performance.
  • Resumo IPEN-doc 29179
    Performance and optimization of a GEM-based neutron detector using a parameterized fast simulator
    2021 - FELIX DOS SANTOS, R.; SERRA FILHO, L.A.; MUNHOZ, M.G.; BREGANT, M.; MORALLES, M.; SOUZA, F.A.
    Neutrons can be detected indirectly through a nuclear reaction where the products are ionizing radiation. Due to the shortage of 3He, most commonly used element for such measurements, several studies are searching alternatives, where the Gas Electron Multiplier (GEM) detector using a layer of 10B as a neutron converter is a very promising option. The GEM detectors are a type of Micro-Pattern Gaseous Detectors (MPGD), widely used in particle tracking systems, as the Time Projection Chamber of the ALICE experiment in the LHC-CERN, and proposed for many other applications, including neutron detection. A common strategy to simulate this kind of detector is based on two frameworks: Geant4 and Garfield++. The first one provides the simulation of the nuclear interaction between neutrons and the 10B layer, while the second allows the simulation of the interaction of the reaction products with the detector gas leading to the ionization and excitation of the gas molecules. Given the high ionizing power of this nuclear reaction products, a full simulation is very time consuming and must be optimized to become viable. We developed a fast simulator by means of parameterization strategy based on these two frameworks that allowed us to generate enough data to study an optimized version of this detector aiming for a better position resolution.
  • Resumo IPEN-doc 29177
    Position sensitive GEM-based thermal neutron detector prototype with 10B4C converter
    2021 - SERRA FILHO, L.A.; FELIX DOS SANTOS, R.; SOUZA, G.G.A. de; BREGANT, M.; MUNHOZ, M.G.; SOUZA, F.A.; MORALLES, M.; NATAL DA LUZ, H.
    In the last decade, several efforts have been made by the scientific community to find alternatives to 3He, the most effective gas used for thermal neutron detection, which is virtually extinct [1]. Common alternatives make use of isotopes such 157Gd, 10B, and 6Li, due to their high neutron capture cross-section [2]. We present in this work our detector prototype: a 10 cm x 10 cm double GEM stack with an aluminum cathode, coated with a 2:2 μm thick 10B4C layer deposited by the European Spallation Source (ESS). The detector operates under ArCO2 (90/10) open flow at atmospheric pressure. The neutrons are detected through the gas ionization charges created by the outcomes of the 10B(n;α)7Li capture reaction. These charges are collected in a 256x256 strip readout plane produced by CERN, connected to resistive chains we designed for this project and produced in the local industry. We tested the prototype in the IPEN IEA-R1 nuclear reactor with a 1:4Å monochromatic neutron beam. We will report experimental measurements showing that the prototype presented high stability, position sensitivity with spatial resolution better than 3mm (obtained by 2 methods), detection efficiency of 2:66(30)%, and good agreement with simulated results regarding the energy spectrum of the neutron capture products. We will finally discuss further methods to be adopted for enhancing detection efficiency.
  • Artigo IPEN-doc 29060
    Double-GEM based thermal neutron detector prototype
    2022 - SERRA FILHO, L.A.; FELIX DOS SANTOS, R.; SOUZA, G.G.A. de; PAULINO, M.M.M.; SOUZA, F.A.; MORALLES, M.; LUZ, H.N. da; BREGANT, M.; MUNHOZ, M.G.; LAI, C.-C.; HOGLUND, C.; SVENSSON, P.-O.; ROBINSON, L.; HALL-WILTON, R.
    The Helium-3 shortage and the growing interest in neutron science constitute a driving factor in developing new neutron detection technologies. In this work, we report the development of a double-GEM detector prototype that uses a 10B4C layer as a neutron converter material. GEANT4 simulations were performed predicting an efficiency of (3.14 ± 0.10)%, agreeing within 2.7σ with the experimental and analytic detection efficiencies obtained by the detector when tested in a 41.8 meV thermal neutron beam. The detector is position sensitive, equipped with a 256+256 strip readout connected to resistive chains, and achieves a spatial resolution better than 3 mm. The gain stability over time was also measured with a fluctuation of about 0.2% h-1 of the signal amplitude. A simple data acquisition with only 5 electronic channels is sufficient to operate this detector.
  • Livro IPEN-doc 28748
    Contribuições do reator IEA-R1 para a pesquisa nuclear
    2022 - SILVA, PAULO S.C. da; ZAHN, GUILHERME S.; SOUZA, FRANCISCO de A.
  • Capítulo IPEN-doc 28712
    Desenvolvimento de detectores de nêutrons sensível à posição
    2022 - SERRA FILHO, L.A.; SOUZA, F.A.; MORALLES, M.; LUZ, H.N. da; BREGANT, M.; MUNHOZ, M.G.
    O Instituto de Pesquisas Energéticas e Nucleares (IPEN) possui atualmente o maior reator de pesquisas nacional (IEA-R1), com algumas linhas de feixes de nêutrons disponíveis tanto para a inserção de novos instrumentos como para utilização desses feixes na caracterização e testes de detectores. Desde 2015 vem sendo desenvolvido, por meio de uma colaboração entre o IPEN e o Centro de Instrumentação e Física de Altas Energias (HEPIC) do Instituto de Física da Universidade de São Paulo (IF-USP), um protótipo de detector de nêutrons térmicos sensível à posição baseado em sistema de microestruturas multiplicadoras de elétrons em gás (GEM). Os experimentos têm sido realizados utilizando o feixe monocromático do difratômetro de nêutrons AURORA instalado no saguão experimental do reator IEA-R1.
  • Artigo IPEN-doc 28300
    Performance and optimization of a GEM-based neutron detector using a parameterized fast simulator
    2021 - SANTOS, R.F. dos; SERRA FILHO, L.A.; MUNHOZ., M.G.; BREGANT, M.; MORALLES, M.; SOUZA, F.A.
  • Artigo IPEN-doc 28228
    GEM-based thermal neutron detector prototype using boron-carbide converter
    2021 - SERRA FILHO, L.A.; SANTOS, R.F. dos; BREGANT, M.; MUNHOZ, M.G.; SOUZA, F.A.; MORALLES, M.; LUZ, H.N. da