LUCIANO BACHMANN

Projetos de Pesquisa
Unidades Organizacionais
Cargo

Resultados de Busca

Agora exibindo 1 - 5 de 5
  • Artigo IPEN-doc 12214
    Characterization of natural carious lesions by fluorescence spectroscopy at 405-nm excitation wavelength
    2007 - ZEZELL, DENISE M.; RIBEIRO, ADRIANA C.; BACHMANN, LUCIANO; GOMES, ANDERSON S.L.; ROUSSEAU, CHRISTEL; GIRKIN, JOHN
  • Artigo IPEN-doc 07131
    Thermal effects during in vitro intracanal application of Nd:YAG laser
    2000 - STREFEZZA, C.; ZEZELL, D.M.; BACHMANN, L.; CECCHINI, S.C.; PINOTTI, M.; EDUARDO, C.P.
  • Artigo IPEN-doc 14035
    Temperature rise in cavities prepared in vitro by Er:YAG laser
    2001 - GOUW SOARES, SHEILA; PELINO, JOSÉ E.P.; HAYPEK, PATRICIA; BACHMANN, LUCIANO; EDUARDO, CARLOS de P.
  • Artigo IPEN-doc 14034
    Cementum melting after dye-assisted holmium laser irradiation
    2004 - BACHMANN, L.; ROSSI, W.; ZEZELL, D.M.
  • Artigo IPEN-doc 11380
    Effect of Er:YAG and diode lasers on the adhesion of blood components and on the morphology of irradiated root surfaces
    2006 - THEODORO, L.H.; SAMPAIO, J.E.C.; HAYPEK, P.; BACHMANN, L.; ZEZELL, D.M.; GARCIA, V.G.
    Objective: The aim of this study was to evaluate in vitro, by scanning electron microscopy (SEM), the adhesion of blood components on root surfaces irradiated with Er:YAG (2.94 lm) and GaAlAs Diode (808 nm) lasers and the effects on the morphology of irradiated root surfaces. Methods: One hundred samples of human teeth were obtained. They were previously planed and scaled with manual instruments and divided into five groups of 20 samples each: G1 (control group) – absence of treatment; G2 – Er:YAG laser (7.6 J/cm2 ); G3 – Er:YAG laser (12.9 J/cm2 ); G4 – Diode laser (90 J/cm2 ) and G5 – Diode laser (108 J/cm2 ). After these treatments, 10 samples of each group received a blood tissue but the remaining 10 did not. After laboratory treatments, the samples were obtained by SEM, the photomicrographs were analysed by the score of adhesion of blood components and the results were statistically analysed (Kruskall–Wallis and Mann–Whitney test). Results: In relation to the adhesion of blood components, the study showed no significant differences between the control group and the groups treated with Er:YAG laser (p ¼ 0.9633 and 0.6229). Diode laser radiation was less effective than control group and Er:YAG laser radiation (p < 0.01). Conclusions: None of the proposed treatments increased the adhesion of blood components in a significant way when compared to the control group. Although the Er:YAG laser did not interfere in the adhesion of blood components, it caused more changes on the root surface, whereas the Diode laser inhibited the adhesion.