PAULO DE TARSO DALLEDONE SIQUEIRA

Projetos de Pesquisa
Unidades Organizacionais
Cargo

Resultados de Busca

Agora exibindo 1 - 10 de 94
  • Artigo IPEN-doc 31167
    Development of a sample exchange system for irradiations in the BH-3 channel of the IEA-R1 reactor at IPEN
    2024 - PAULA, M.L. de; MORALLES, M.; GENEZINI, F.A.; SIQUEIRA, P.T.D.; RIBEIRO JUNIOR, I.S.; SILVA JUNIOR, I.A. da
    This work was developed with the aim of improving the current sample exchange system of the BH-3 irradiation channel of the IEA-R1 reactor at IPEN. The instrument's operating concept will provide a better use of the irradiation space as well as greater safety and confidence to the operator. The development of the system involved 3D modeling, sizing, construction and non-destructive testing of the various parts, and analysis of neutron-induced activation of the materials most exposed to the beam. A programmable logic controller (PLC) was implemented for the system’s control inside a dedicated electrical panel that was built with materials compatible with the location. The system was designed to support samples weighing up to 15 kg. Bench tests were carried out and showed that the system performs the necessary functions to accurately position samples in three locations: outside the biological shield, at the irradiation channel and at the decay waiting station. The implementation of this instrument will contribute to the application of the ALARA principle in the operator activities at the BH-3 irradiation channel.
  • Relatório IPEN-doc 30928
    Resultados de espectrometria gama dos Geradores de Vapor (GVs)
    2024 - MEDEIROS, JOSE A.G.; SIQUEIRA, PAULO de T.D.
    Este documento tem por objetivo apresentar os resultados de espectrometria gama dos dois Geradores de Vapor (GVs) depositados no prédio do Depósito Inicial dos Geradores de Vapor no sítio da CNAAA. Os resultados foram obtidos na campanha de medida realizada entre os dias 26 de fevereiro e 6 de março de 2024. Os dados obtidos com um detector de germânio hiper-puro (HPGe) permitiram a identificação e avaliação da distribuição do 60Co, como o principal radionuclídeo gama emissor presente nos GVs. Apresenta-se adicionalmente a comparação entre os resultados espectrométricos obtidos para cada GV e a estimativa da atividade devida ao 60Co presente em cada GV. As informações apresentadas neste relatório são de grande relevância para o atendimento ao item 8.4.2 - “Realização e apresentação dos resultados da espectrometria gama dos Geradores de Vapor e da Tampa do Vaso do Reator.” do Plano de Trabalho revisado, após formalização do termo de aditivo, anexo ao Acordo de Parceria Tecnológica firmado entre a Eletrobrás Termonuclear S.A., a CNEN – Comissão Nacional de Energia Nuclear e a FUNDEP – Fundação de Desenvolvimento da Pesquisa.
  • Relatório IPEN-doc 30925
    Modelagem computacional dos geradores de vapor e da tampa do vaso do reator
    2024 - YORIYAZ, HELIO; MEDEIROS, JOSE A.G. de; SIQUEIRA, PAULO de T.D.
    Este relatório apresenta a descrição da metodologia de cálculo que está sendo desenvolvida para a estimativa do inventário radioativo do Gerador de Vapor (GV), e da Tampa do Vaso do Reator (TVR), bem como, os principais resultados e análises realizados até o momento através de simulações computacionais. A simulação computacional de qualquer problema começa com a construção de um modelo computacional que irá representar o problema que está sendo estudado. No presente caso, isso engloba a modelagem da geometria do GV e da TVR, assim como as composições e densidades dos materiais que compõem essas estruturas. Neste sentido, o presente trabalho consistiu na elaboração de vários modelos computacionais que levam em consideração diferentes características geométricas e também diferentes densidades e composições de materiais, no sentido de buscar a melhor representação ou modelo computacional de cálculo de dose para estimativa do inventário do 60Co presente nessas estruturas. A ferramenta principal de análise é o código computacional para o transporte de radiação baseado no Método de Monte Carlo (MMC) denominado MCNP versões 5 e 6.1. Este código permite uma grande versatilidade em trabalhar com geometrias complexas, sendo amplamente utilizado em problemas na área nuclear. Este documento visa atender o item 8.4.3 – “Estudos sobre a modelagem computacional para a estimativa do inventário da Tampa do Vaso do Reator e do Gerador de Vapor” do plano de trabalho anexo ao acordo “Determinação da Composição Isotópica dos Rejeitos Radioativos de Baixo e Médio Nível de Radiação da CNAAA (Fase B)”. Os resultados mostrados neste relatório foram obtidos baseados em dimensões e composições de materiais conforme descrito. Entretanto, com a evolução do trabalho, foi desenvolvido um novo modelo computacional de gerador de vapor com dados atualizados e corrigidos, sendo que, está sendo preparada uma nova versão deste relatório com novos resultados obtidos.
  • Artigo IPEN-doc 30620
    Study of the behavior of 3 MeV proton beams on PMMA
    2024 - PEREIRA, J.; MATIAS, F.; ANTUNES, P.; SHORTO, J.; SIQUEIRA, P.; SILVA, T.; RODRIGUES, C.; OTUBO, L.; FERREIRA, G.; YORIYAZ, H.
  • Artigo IPEN-doc 30433
    Efficient computational modeling of electronic stopping power of organic polymers for proton therapy optimization
    2024 - MATIAS, F.; SILVA, T.F.; KOVAL, N.E.; PEREIRA, J.J.N.; ANTUNES, P.C.G.; SIQUEIRA, P.T.D.; TABACNIKS, M.H.; YORIYAZ, H.; SHORTO, J.M.B.; GRANDE, P.L.
    This comprehensive study delves into the intricate interplay between protons and organic polymers, offering insights into proton therapy in cancer treatment. Focusing on the influence of the spatial electron density distribution on stopping power estimates, we employed real-time time-dependent density functional theory coupled with the Penn method. Surprisingly, the assumption of electron density homogeneity in polymers is fundamentally flawed, resulting in an overestimation of stopping power values at energies below 2 MeV. Moreover, the Bragg rule application in specific compounds exhibited significant deviations from experimental data around the stopping maximum, challenging established norms.
  • Artigo IPEN-doc 30387
    Thermal neutron dose measurements using TLD-100 detectors in the IPEN/MB-01 reactor core
    2024 - CAVALIERI, TASSIO A.; SIQUEIRA, PAULO de T.D.; SHORTO, JULIAN M.B.; YORIYAZ, HELIO
    Considerable experimental effort has been aimed at uncovering a reliable way to perform a dosimetric assessment in mixed radiation fields. In fields composed by gammas and neutrons, TLD dosimeters are usually applied to execute such measurements, although there is no consensus on the most favorable strategy to employ them. In this context, TLD-100 measurements within two different core configurations of the IPEN/MB-01 research reactor and Monte Carlo simulations have been used to investigate the behavior of those detectors in multiple mixed radiation fields, deriving a methodology to evaluate the dose deposition in the dosimeter by different gamma and neutron energy spectra and intensities. A surprising outcome is the linear neutron dose response shown by TLD-100 even irradiated by so distinct irradiation fields.
  • Artigo IPEN-doc 30038
    Heterogeneous physical phantom for I-125 dose measurements and dose-to-medium determination
    2024 - ANTUNES, PAULA C.G.; SIQUEIRA, PAULO de T.D.; SHORTO, JULIAN M.B.; YORIYAZ, HELIO
    PURPOSE: In this paper we present a further step in the implementation of a physical phantom designed to generate sets of “true”independent reference data as requested by TG-186, intending to address and mitigate the scarcity of experimental studies on brachytherapy (BT) validation in heterogeneous media. To achieve this, we incorporated well-known heterogeneous materials into the phantom in order to perform measurements of 125I dose distribution. The work aims to experimentally validate Monte Carlo (MC) calculations based on MBDCA and determine the conversion factors from LiF response to absorbed dose in different media, using cavity theory. METHODS AND MATERIALS: The physical phantom was adjusted to incorporate tissue equivalent materials, such as: adipose tissue, bone, breast and lung with varying thickness. MC calculations were performed using MCNP6.2 code to calculate the absorbed dose in the LiF and the dose conversion factors (DCF). RESULTS: The proposed heterogeneous phantom associated with the experimental procedure carried out in this work yielded accurate dose data that enabled the conversion of the LiF responses into absorbed dose to medium. The results showed a maximum uncertainty of 6.92 % ( k = 1), which may be considered excellent for dosimetry with low-energy BT sources. CONCLUSIONS: The presented heterogeneous phantom achieves the required precision in dose evaluations due to its easy reproducibility in the experimental setup. The obtained results support the dose conversion methodology for all evaluated media. The experimental validation of the DCF in different media holds great significance for clinical procedures, as it can be applied to other tissues, including water, which remains a widely utilized reference medium in clinical practice.
  • Artigo IPEN-doc 30237
    Comparison of methodologies for creating spread-out Bragg peaks in proton therapy using TOPAS and MCNP codes
    2023 - BRANCO, I.S.L.; BURIN, A.L.; PEREIRA, J.J.N.; SIQUEIRA, P.T.D.; SHORTO, J.M.B.; YORIYAZ, H.
    In proton beam treatments, the superposition of several weighted Bragg curves with different incident energies is required to homogeneously irradiate a large tumor volume, creating a spread-out Bragg peak (SOBP). This paper confirms on the suitability of two different methods to create SOBPs – Bortfeld/Jette’s and MCMC (Monte Carlo calculations and Matrix Computations), using Monte Carlo simulations performed with TOPAS and MCNP6.1. To generate the SOBPs, algorithms were developed for implementation of the two methods, which enabled to find the weights for thirty variations of SOBPs, categorized according to their width and maximum depths. The MCMC method used weight optimization in designing SOBPs to avoid negative values. In contrast, the Bortfeld/ Jette’s method yielded the SOBPs according to the variation of a power-law parameter (p) introduced by the range-energy relationship. Optimal values of p, from MCNP and TOPAS, were selected in order to retrieve SOBPs with the best smoothness and then related to those obtained from the literature. In comparing both methods and codes, dose homogeneity parameters (HOM) were used to examine the SOBP flatness and gamma analyses were employed to assess the dose deposition along its full extension. The results showed that the SOBPs designed using the MCMC method had better HOM values and computational performance for both codes when compared to the Bortfeld/Jette’s method. The gamma analyses highlighted significant differences between the entrance doses comparing the two different methods, for SOBPs with intermediate and high depths and small width. This evaluation was not possible with the HOM values alone, which stresses the relevance of a broad analysis to avoid unintended doses in healthy tissues.
  • Artigo IPEN-doc 30238
    Avaliação da sensibilidade do ArcCHECK na detecção de erros de posicionamento do MLC
    2023 - BIAGIONI, FERNANDA G.; CAMPANELLI, HENRIQUE B.; RIBEIRO, VICTOR A.B.; SIQUEIRA, PAULO T.D.; SHORTO, JULIAN M.B.; SERANTE, ALEXANDRE R.
    Técnicas modernas de tratamento como a técnica de Arcoterapia Volumétrica Modulada (VMAT, do inglês Volumetric Modulated Arc Therapy) têm sido amplamente utilizadas na prática clínica para diversas regiões de tratamento e a avaliação do efeito dosimétrico devido a erros de posicionamento do multileaf (MLC) tem sido estudada por alguns autores. O objetivo desse trabalho foi avaliar a sensibilidade do ArcCHECK em detectar erros de posicionamento do MLC em campos estáticos, em arcos estáticos e para planejamentos do AAPM TG-119 usando análise gamma com os critérios de 3%/3 mm, 3%/2 mm e 2%/2 mm. Os resultados encontrados sugerem que o ArcCHECK é sensível para detectar erros sistemáticos e randômicos maiores do que 2 mm, nos casos do AAPM TG-119 utilizando os critérios gamma de 3%/3 mm, 3%/2 mm 2%/2 mm. Porém usar apenas análise gamma possibilita que alguns erros não sejam detectados na prática clínica, se a porcentagem de pontos aprovados com índice gamma é maior que o índice de confiança da instituição.
  • Resumo IPEN-doc 30005
    Análise comparativa de modelos matemáticos no desenvolvimento de um Algoritmo Pencil Beam para protonterapia
    2023 - BRANCO, I.S.L.; SIQUEIRA, P.T.D.; SHORTO, J.M.B.; YORIYAZ, H.
    Introdução: Em protonterapia, a distribuição de dose é calculada por meio de algoritmos analíticos, como o Algoritmo Pencil Beam (PBA), que requer a estimativa de parâmetros para a fluência no ar e dose na água. Este estudo utilizou o código TOPAS para modelar o feixe e analisou a influência dos modelos matemáticos no cálculo de dose com o PBA. Materiais e Métodos: Simulações com o TOPAS calcularam a fluência no ar, dose elementar na água e dose de referência para prótons de 187 MeV. Três distintos modelos matemáticos parametrizaram a distribuição de fluência no ar e cinco a dose elementar na água, resultando em 15 convoluções que foram comparadas com a dose de referência. A Figura 1 apresenta as diferenças relativas de dois dos resultados obtidos. Resultados e Discussões: Entre as convoluções realizadas, destaca-se a que utilizou a fluência ajustada com a Gaussiana Dupla e a dose elementar com a Gaussiana Dupla e Cauchy. Essa convolução apresentou pequenas diferenças relativas nas doses laterais de entrada do feixe e menores diferenças quando comparadas aos outros modelos. Conclusões: A precisão dos cálculos de dose no PBA é grandemente influenciada pela escolha dos modelos matemáticos para parametrizar a fluência e dose elementar, especialmente para baixas doses (distantes do eixo central).