LUCAS VERDI ANGELOCCI

Projetos de Pesquisa
Unidades Organizacionais
Cargo

Resultados de Busca

Agora exibindo 1 - 3 de 3
  • Artigo IPEN-doc 26136
    End-weld thickness variation effects on dose rate for a new ir-192 brachytherapy source
    2019 - ANGELOCCI, LUCAS V.; NOGUEIRA, BEATRIZ R.; ABREU, RODRIGO T.; ZEITUNI, CARLOS A.; ROSTELATO, MARIA E.C.M.
    Brachytherapy is a form of radiation therapy that uses small sealed sources close to the tumor to deliver a high dose to target while keeping dose on neighboring healthy tissues as low as possible. A wide variety of radionuclides and different sources are available for brachytherapy, each with his own unique geometry. The Laboratory of Sources Production for Radiotherapy (IPEN/CNEN) developed a new Ir-192 seed for eye tumor treatment that is currently under dosimetric definition. This work is part of a larger project that aims the full dosimetry of this new source, but rather than calculate the usual parameters proposed by the American Association of Physicists in Medicine, the specific contribution to the dose rate of a usually not considered factor was investigated under a statistical approach: end-weld thickness variation, which is important due to this source being welded by an in-house method. Its effects were investigated using the Monte Carlo radiation transport code MCNP4C and an in-house routine programmed with MATLAB® to analyze the data. Final results are presented as a mean value for dose rate at different points of interest and their associated standard deviations. The results are discussed based on the influence of said parameter on different points around the source.
  • Artigo IPEN-doc 25055
    Mesh-based human eye anatomy for Monte Carlo dose calculation
    2018 - ANGELOCCI, LUCAS V.; YORIYAZ, HELIO
    Purpose: The purpose of this work is to explore the capability of the MCNP6 unstructured mesh geometry resources to create an eye and tumor anatomic model for ophthalmic brachytherapy dosimetry. Methods: Abaqus/CAE software was utilized to construct three anatomic eye models using first order tetrahedral mesh elements: a model with a 2 cm in diameter deep tumor; a model with a 1.2 cm in diameter deep tumor; and a model with a 1.2 cm superficial tumor. 2 cm and 1.2 cm COMS applicators fully loaded with Amersham 6711125I seeds were coupled to the eye models for dose calculation using the MCNP6 code. The dose values in the structures of the eye were compared to those obtained using analytical models. Results: Unstructured mesh model has small differences (maximum of 3.4%) in the mass values of the components of the eye comparing to those obtained in the analytical model. Excluding the optical nerve wall, all dose differences were beneath 4% for all structures. The overall dose in the eye agrees within 2% between different models. Conclusions: The feasibility of using unstructured mesh based geometries to model fine structures of the eye has been verified in this study. It was possible to create adequately the anatomic model of the human eye with reproducible dose values compared to reference values.
  • Artigo IPEN-doc 21052
    Human eye analytical and mesh-geometry models for opthtalmic dosimetry using MCNP6
    2015 - ANGELOCCI, LUCAS V.; FONSECA, GABRIEL P.; YORIYAZ, HELIO