MARCELO FRANCIS MADUAR

Resumo

Doctorate (2010) and Master (2000) degrees in Nuclear Technology at SĆ£o Paulo University, Physics Bachelorate at SĆ£o Paulo University (1996) and Technologist in Data Processing at Universidade Estadual Paulista JĆŗlio de Mesquita Filho (1989). Experience in Experimental Physics, focusing on Experimental Methods and Instrumentation for Elementary Particles and Nuclear Physics. (Text obtained from the CurrĆ­culo Lattes on November 16th 2021)


Doutorado (2010) e Mestrado (2000) em Tecnologia Nuclear pela Universidade de SĆ£o Paulo, Bacharelado em FĆ­sica pela Universidade de SĆ£o Paulo (1996) e graduaĆ§Ć£o em Tecnologia Em Processamento de Dados pela Universidade Estadual Paulista JĆŗlio de Mesquita Filho (1989). Tecnologista senior do Instituto de Pesquisas EnergĆ©ticas e Nucleres (IPEN), Ć³rgĆ£o da ComissĆ£o Nacional de Energia Nuclear (CNEN). Gerente adjunto (desde julho/2018) do ServiƧo de GestĆ£o de Radiometria Ambiental (SEGRA) do IPEN. Tem experiĆŖncia na Ć”rea de FĆ­sica, com ĆŖnfase em MĆ©todos Experimentais e InstrumentaĆ§Ć£o para Detectores de RadiaĆ§Ć£o, atuando principalmente nos seguintes temas: espectrometria gama, radioatividade ambiental e aplicaĆ§Ć£o de mĆ©todos computacionais na avaliaĆ§Ć£o de espectros gama, em modelos de dispersĆ£o ambiental e em dose externa decorrente de radiaĆ§Ć£o gama. Orientador de Mestrado do Programa de PĆ³s-GraduaĆ§Ć£o em Tecnologia Nuclear do IPEN - Ć”rea de AplicaƧƵes (TNA) a partir de maio de 2019 e docente das disciplinas TNA5754, Radioatividade no meio ambiente e avaliaĆ§Ć£o de impacto radiolĆ³gico ambiental, e TNA5733, TĆ³picos AvanƧados de Medidas Nucleares. (Texto extraĆ­do do CurrĆ­culo Lattes em 16 nov. 2021)

Projetos de Pesquisa
Unidades Organizacionais
Cargo

Resultados de Busca

Agora exibindo 1 - 1 de 1
  • Artigo IPEN-doc 27192
    Optimization of the gamma-ray spectrometry counting time based on uncertainties of radionuclides concentration in samples
    2020 - NISTI, M.B.; MADUAR, M.F.; SAUEIA, C.H.R.; CAVALCANTE, F.; MAZZILLI, B.P.
    This paper aims to propose an easy and fast method of optimization of the gamma-ray spectrometry counting time in determining natural radionuclides (210Pb, 212Pb, 214Pb, 212Bi, 214Bi and 228Ac) in order to minimize uncertainties in the concentration. The samples were measured by gamma-ray spectrometry with a hyper-pure germanium detector Canberra, 25% relative efficiency, effective resolution of 1.9 keV on the 1332.5 keV 60Co with associated electronics and coupled to a microcomputer. Multichannel Maestro A65-I model was used for spectrum acquisition and peak net area determination, and WinnerGamma/Interwinner 6.01 software was used for gamma-ray spectra analysis and to calculate the concentrations and associated uncertainties. The counting times used were 86,000 s and 150,000 s.