Evaluation of fetal, medical and occupational exposure in ERCP procedures using Monte Carlo simulation and virtual anthropomorphic phantoms

dc.contributor.authorSANTOS, WILLIAM S.pt_BR
dc.contributor.authorSOUZA, LUCAS W.G.pt_BR
dc.contributor.authorNEVES, LUCIO P.pt_BR
dc.contributor.authorPERINI, ANA P.pt_BR
dc.contributor.authorSANTOS, CARLA J.pt_BR
dc.contributor.authorBELINATO, WALMIRpt_BR
dc.contributor.authorCALDAS, LINDA V.E.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2020-12-11T17:39:48Z
dc.date.available2020-12-11T17:39:48Z
dc.date.issued2020pt_BR
dc.description.abstractIn this study, computational modeling was applied to evaluate medical and occupational exposure, to ionizing radiation, during the Endoscopic Retrograde Cholangiopancreatography (ERCP) procedure of a pregnant woman in the second gestational trimester. The fetal dose evaluation and the construction of a photon fluence map inside the procedure room were also performed. The medical staff and patient were represented by virtual anthropomorphic phantoms. These phantoms were incorporated to the radiation transport code MCNPX (version 2.7.0). The photon beam was projected on the right lateral lower section of the liver of the patient, producing a FOV of 15×15 cm2. The spectral influence was evaluated using tube voltages of 70 kVp and 80 kVp with a total filtration of 5 mmAl. The influence of the suspended shield, lead curtain and fetal shield were evaluated on the Conversion Coefficients for Equivalent Dose (CC[HT]) and Effective Dose (CC[E]) for the medical staff and patient. The removal of the lead curtain and suspended shield was considered the most critical configuration to the medical staff. In this situation, an increase up to 633% in the CC[HT]eye lens and 900% in CC[E], for the medical staff, was reached. The CC[E]Patient ranged between 0.13 mSv/Gy.cm2 (70 kVp with all protective devices) and 0.15 mSv/Gy.cm2 (80 kVp without fetal shield) and the values obtained are in agreement with the literature. The CC[HT]fetus oscillated between 2.2E-1 mSv/Gy.cm2 (70 kV with fetal shield) and 2.7E-1 mSv/Gy.cm2 (80 kV without fetal shield). The outcomes of this work are useful in the prior monitoring of the radiation doses and risks, and a reduction on these may be reached for the medical team and patient, which is a complicated arrangement in ERCP procedures.pt_BR
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de Minas Gerais (FAPEMIG)pt_BR
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)pt_BR
dc.description.sponsorshipIDFAPEMIG: APQ-03049-15; APQ-02934-15pt_BR
dc.description.sponsorshipIDCNPq: 421603/2016-0; 420699/2016-3; 301335/2016-8pt_BR
dc.format.extent1-10pt_BR
dc.identifier.citationSANTOS, WILLIAM S.; SOUZA, LUCAS W.G.; NEVES, LUCIO P.; PERINI, ANA P.; SANTOS, CARLA J.; BELINATO, WALMIR; CALDAS, LINDA V.E. Evaluation of fetal, medical and occupational exposure in ERCP procedures using Monte Carlo simulation and virtual anthropomorphic phantoms. <b>Radiation Physics and Chemistry</b>, v. 177, p. 1-10, 2020. DOI: <a href="https://dx.doi.org/10.1016/j.radphyschem.2020.109113">10.1016/j.radphyschem.2020.109113</a>. Disponível em: http://200.136.52.105/handle/123456789/31650.
dc.identifier.doi10.1016/j.radphyschem.2020.109113pt_BR
dc.identifier.issn0969-806Xpt_BR
dc.identifier.orcid0000-0002-7362-2455pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.percentilfi66.43pt_BR
dc.identifier.percentilfiCiteScore72.00
dc.identifier.urihttp://200.136.52.105/handle/123456789/31650
dc.identifier.vol177pt_BR
dc.relation.ispartofRadiation Physics and Chemistrypt_BR
dc.rightsopenAccesspt_BR
dc.subjectbiomedical radiography
dc.subjectdigestive system
dc.subjectpregnancy
dc.subjectprenatal exposure
dc.subjectpatients
dc.subjectmonte carlo method
dc.subjectphantoms
dc.subjectmedical personnel
dc.subjectnuclear medicine
dc.subjectconversion
dc.subjectcomputerized simulation
dc.subjectmathematical models
dc.subjectradiation doses
dc.subjectfetuses
dc.titleEvaluation of fetal, medical and occupational exposure in ERCP procedures using Monte Carlo simulation and virtual anthropomorphic phantomspt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorLINDA V. E. CALDAS
ipen.codigoautor1495
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.date.recebimento20-12
ipen.identifier.fi2.858pt_BR
ipen.identifier.fiCiteScore3.8
ipen.identifier.ipendoc27422pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi1.500 - 2.999
ipen.range.percentilfi50.00 - 74.99
ipen.type.genreArtigo
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublication.latestForDiscovery7f46d4f4-dfd6-4485-a767-10df5b4f4f13
sigepi.autor.atividadeCALDAS, LINDA V.E.:1495:330:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
27422.pdf
Tamanho:
2.39 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções