Comparison of 238U mass fraction measured by ICP–MS and Instrumental Neutron Activation Analysis techniques

Carregando...
Imagem de Miniatura
Data
Data de publicação:
2022
Orientador
Título da Revista
ISSN da Revista
Título do Volume
É parte de
É parte de
É parte de
É parte de
IBEROAMERICAN CONFERENCE ON MASS SPECTROMETRY, 3rd
Exportar
Mendeley
Projetos de Pesquisa
Unidades Organizacionais
Fascículo
Resumo
Introduction: Uranium is an element present in ambient air, water, soil and rocks [1]. The most abundant natural radioisotope of this actinide (238U) produces in its chain decay the radionuclide 222Rn [2], which is a tracer for atmospheric mixing and transport model validations [3]. The 238U activity concentration in superficial soil samples is a crucial parameter for some 222Rn flux map modeling methodologies [4]. Methods: In this study, 18 superficial soil samples were analyzed. The content of 238U was assessed using two techniques: (i) by the comparative method of the Instrumental Neutron Activation Analysis (INAA) [5] and by ICP–MS (ELAN 6000, PerkinElmer) [6]. Certified Reference Materials (CRM) SRM 1646a Estuarine Sediment and USG STM–2 were used both as comparators in the INAA technique and to ensure quality control. The normality and homoscedasticity of the data were evaluated. Finally, the Mann- Whitney U test [7] was used to assess whether or not there is a significant difference (α = 0.05) between the two techniques. Results: The z-score was calculated to ensure quality control. Z-scores values was obtained by the Modified Horwitz Equation [8], which takes into account the order of magnitude of the content of the analyte and is independent of the CRM uncertainties, unavailable for the CRM used. The z-score values obtained (n = 3) for the radionuclide 238U were 0.5 for the CRM USG STM–2 and -0.4 for SRM 1646a. The z-scores obtained are smaller than 2 therefore they are considered satisfactory [9]. Regarding the statistical parameters of the comparison between the techniques, the normality (Shapiro Wilk) was not verified (p = 0.02 for ICP-MS and p = 0.03 for INAA). The p-value for the test for equal variances (F test) was 0.71 Mann-Whitney U test was used instead of Student’s test due to the non-verification of the normality parameter in the data. The p-value from the Mann-Whitney test (0.51) indicates that there is no significant difference between the 238U content measured by the two techniques. Conclusions: Statistical analysis showed that there is no significant difference between the 238U mass fraction measured by the ICP–MS and the INAA – comparative method. In the future, certified reference materials will also be assessed by ICP–MS in order to corroborate this statistical comparison from a metrological point of view.

Como referenciar
TAPPIZ, BRUNO; SILVA, PAULO S.C. da; OSTERMANN, CAROLINE; LIMA, NICOLE P. de; ANDRADE, MARIANA N. de; BUSTILLOS, OSCAR V. Comparison of 238U mass fraction measured by ICP–MS and Instrumental Neutron Activation Analysis techniques. In: SIMIONATO, ANA V.C. (coord.). In: IBEROAMERICAN CONFERENCE ON MASS SPECTROMETRY, 3rd, December 10-15, 2022, Rio de Janeiro, RJ. Abstract... Campinas, SP: Sociedade Brasileira de Espectrometria de Massas - BrMASS, 2022. p. 237-238. Disponível em: http://repositorio.ipen.br/handle/123456789/33929. Acesso em: 28 Feb 2025.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.

Agência de fomento