Experimental and Monte Carlo evaluation of the neutron flux of an assembly with two AmBe sources
| dc.contributor.author | MADI FILHO, TUFIC | pt_BR |
| dc.contributor.author | LIMA, RUY B. de | pt_BR |
| dc.contributor.author | YORIYAZ, H. | pt_BR |
| dc.contributor.author | HERNANDES, ANTONIO C. | pt_BR |
| dc.coverage | Internacional | pt_BR |
| dc.date.accessioned | 2014-07-15T13:48:38Z | pt_BR |
| dc.date.accessioned | 2014-07-30T11:49:45Z | |
| dc.date.available | 2014-07-15T13:48:38Z | pt_BR |
| dc.date.available | 2014-07-30T11:49:45Z | |
| dc.date.issued | 2005 | pt_BR |
| dc.description.abstract | This work aimed to determine the irradiator thermal (under-cadmium) and fast (over-cadmium) neutron fluxes, of the Nuclear Experimental Laboratory of the Nuclear Engineering Center (CNEN–IPEN, Sa˜o Paulo, Brazil), and the possibility of this irradiator use for Neutron Activation Analysis (NAA), by the absolute method. To establish the facility specifications, the neutron flux values along the irradiator axis were determined experimentally and calculated by Monte Carlo method. The irradiator presents the advantage of supplying a stable neutron flux for a long period, eliminating the need to use standard material (comparative method), so that the process becomes agile, practical and economical. | |
| dc.format.extent | 412-414 | pt_BR |
| dc.identifier.citation | MADI FILHO, TUFIC; LIMA, RUY B. de; YORIYAZ, H.; HERNANDES, ANTONIO C. Experimental and Monte Carlo evaluation of the neutron flux of an assembly with two AmBe sources. <b>Radiation Protection Dosimetry</b>, v. 115, n. 1-4, p. 412-414, 2005. DOI: <a href="https://dx.doi.org/10.1093/rpd/nci150">10.1093/rpd/nci150</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/5482. | |
| dc.identifier.doi | 10.1093/rpd/nci150 | |
| dc.identifier.fasciculo | 1-4 | pt_BR |
| dc.identifier.issn | 0144-8420 | pt_BR |
| dc.identifier.orcid | https://orcid.org/0000-0003-4023-236X | |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/5482 | pt_BR |
| dc.identifier.vol | 115 | pt_BR |
| dc.relation.ispartof | Radiation Protection Dosimetry | pt_BR |
| dc.rights | closedAccess | en |
| dc.subject | irradiation devices | pt_BR |
| dc.subject | neutron flux | pt_BR |
| dc.subject | neutron sources | pt_BR |
| dc.subject | neutron activation analysis | pt_BR |
| dc.subject | monte carlo method | pt_BR |
| dc.title | Experimental and Monte Carlo evaluation of the neutron flux of an assembly with two AmBe sources | pt_BR |
| dc.type | Artigo de periódico | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | HELIO YORIYAZ | |
| ipen.autor | RUY BARROS DE LIMA | |
| ipen.autor | TUFIC MADI FILHO | |
| ipen.codigoautor | 80 | |
| ipen.codigoautor | 2901 | |
| ipen.codigoautor | 1231 | |
| ipen.contributor.ipenauthor | HELIO YORIYAZ | |
| ipen.contributor.ipenauthor | RUY BARROS DE LIMA | |
| ipen.contributor.ipenauthor | TUFIC MADI FILHO | |
| ipen.date.recebimento | 06-09 | pt_BR |
| ipen.identifier.fi | 0.490 | pt_BR |
| ipen.identifier.ipendoc | 11387 | pt_BR |
| ipen.identifier.iwos | WoS | pt_BR |
| ipen.range.fi | 0.001 - 1.499 | |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | 93102dac-f89d-4743-b6ea-5158708cbb92 | |
| relation.isAuthorOfPublication | 4322d2c2-f616-4828-a3ef-0fbce5108124 | |
| relation.isAuthorOfPublication | c6d485fe-9927-427a-93a0-0104d2bf801e | |
| relation.isAuthorOfPublication.latestForDiscovery | c6d485fe-9927-427a-93a0-0104d2bf801e | |
| sigepi.autor.atividade | MADI FILHO, TUFIC:1231:21:S | pt_BR |
| sigepi.autor.atividade | LIMA, RUY B. DE:2901:-1:N | pt_BR |
| sigepi.autor.atividade | YORIYAZ, H.:80:21:N | pt_BR |
Pacote Original
1 - 1 de 1