Assessment of dosimetric parameters in mammography employing a homemade ionization chamber

dc.contributor.authorSILVA, J.O.
dc.contributor.authorCALDAS, L.V.E.
dc.coverageNacionalpt_BR
dc.date.accessioned2017-04-07T18:13:38Z
dc.date.available2017-04-07T18:13:38Z
dc.date.issued2016pt_BR
dc.description.abstractX-ray mammography examination is the reference tool to discover breast cancer in an early stage. The mammography unit must follow an accurate quality control program that covers both patient and staff radiation protection. Plane parallel ionization chambers are the reference instrument for dosimetry in mammography beams, but they can represent higher cost for small clinics in countries as Brazil. In this work, it is presented a low cost ionization chamber for mammography X-rays energy range dosimetry developed at IPEN. The homemade ionization chamber has a sensitive volume of 6.0 cm3 and it was utilized to execute quality control tests in two distinct mammography systems: a GE Senographe DMR-plus and a Philips VMI Graph Mammo. The setups for the tests performed agreed with the IAEA HHS 2 and 17 recommendations. A breast phantom of various PMMA thicknesses was utilized in this work. The homemade ionization chamber performance was compared to that of a commercial one. The maximum difference between the incident air kerma measured with the reference ionization chamber and the developed one was only 5.62% for the GE equipment and only 4.42% for the Philips equipment. The homemade ionization chamber presented an excellent performance in incident air kerma and HVL measurements for the radiographic techniques utilized in the present work. All the results obtained were within IAEA specifications.pt_BR
dc.format.extent1-11pt_BR
dc.identifier.citationSILVA, J.O.; CALDAS, L.V.E. Assessment of dosimetric parameters in mammography employing a homemade ionization chamber. <b>Scientia Plena</b>, v. 12, n. 12, p. 1-11, 2016. DOI: <a href="https://dx.doi.org/10.14808/sci.plena.2016.124101">10.14808/sci.plena.2016.124101</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/27369.
dc.identifier.doi10.14808/sci.plena.2016.124101pt_BR
dc.identifier.fasciculo12pt_BR
dc.identifier.issn1808-2793pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/27369
dc.identifier.vol12pt_BR
dc.relation.ispartofScientia Plenapt_BR
dc.rightsopenAccesspt_BR
dc.subjectx-ray radiography
dc.subjectmammary glands
dc.subjectionization chambers
dc.subjectradiation doses
dc.subjectglands
dc.subjectbeams
dc.subjectkerma
dc.subjectdosimetry
dc.titleAssessment of dosimetric parameters in mammography employing a homemade ionization chamberpt_BR
dc.title.alternativeEstimativa de parâmetros dosimétricos em mamografia utilizando uma câmara de ionização caseirapt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorLINDA V. E. CALDAS
ipen.autorJONAS OLIVEIRA DA SILVA
ipen.codigoautor1495
ipen.codigoautor8642
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.contributor.ipenauthorJONAS OLIVEIRA DA SILVA
ipen.date.recebimento17-04pt_BR
ipen.identifier.fiSem F.I.pt_BR
ipen.identifier.ipendoc23961pt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublication77802016-c13e-456c-af52-abafa39cddd7
relation.isAuthorOfPublication.latestForDiscovery77802016-c13e-456c-af52-abafa39cddd7
sigepi.autor.atividadeSILVA, J.O.:8642:-1:Spt_BR
sigepi.autor.atividadeCALDAS, L.V.E.:1495:330:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
23961.pdf
Tamanho:
630.5 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções