Impact of oscilloscope connections and bandwidth on signal formation from a SiPM coupled to a LYSO scintillator for gamma spectroscopy

dc.contributor.authorPEROTONI, MARCELO B.
dc.contributor.authorKONSTANTINOU, GEORGIOUS
dc.contributor.authorSANTOS, ADELSON D. dos
dc.contributor.authorBONIFACIO, DANIEL A.B.
dc.coverageInternacional
dc.date.accessioned2026-02-12T19:47:20Z
dc.date.available2026-02-12T19:47:20Z
dc.date.issued2026
dc.description.abstractThis article explores the signal produced by a silicon photomultiplier (SiPM) coupled to a LYSO scintillator in gamma spectroscopy using time and frequency-domain measurements with an oscilloscop. Analyses were performed to address the influence of coaxial cables and oscilloscope probes in the measurements. Limitations of the oscilloscopes bandwidth on the extracted pulses were studied, as well as investigation of the effect of the ambient disturbances, using the two types of cable connections. The analytic Fourier transform of the pulse is analyzed, to indentify the parameters correlating both time and frequency domain. Since there are no further additional amplifiers or signal conditioning stages after the sensor, the results represent the unfiltered signal shape collected by the oscilloscope input impedance. Conclusions are presented as guidelines and design trade-offs concerning the instrumentation and pre-amplifier design.
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipFinanciadora de Estudos e Projetos (FINEP)
dc.description.sponsorshipIDFAPESP: 20/13879-4; 23/00079-8
dc.description.sponsorshipIDCNPq: 202378/2020-9; 435039/2018-0
dc.description.sponsorshipIDFINEP: 0294/16
dc.format.extent1-9
dc.identifier.citationPEROTONI, MARCELO B.; KONSTANTINOU, GEORGIOUS; SANTOS, ADELSON D. dos; BONIFACIO, DANIEL A.B. Impact of oscilloscope connections and bandwidth on signal formation from a SiPM coupled to a LYSO scintillator for gamma spectroscopy. <b>Nuclear Engineering and Technology</b>, v. 58, n. 2, p. 1-9, 2026. DOI: <a href="https://dx.doi.org/10.1016/j.net.2025.103934">10.1016/j.net.2025.103934</a>. Disponível em: https://repositorio.ipen.br/handle/123456789/49307.
dc.identifier.doi10.1016/j.net.2025.103934
dc.identifier.fasciculo2
dc.identifier.issn1738-5733
dc.identifier.percentilfi84.1
dc.identifier.percentilfiCiteScore80.00
dc.identifier.urihttps://repositorio.ipen.br/handle/123456789/49307
dc.identifier.vol58
dc.language.isoeng
dc.relation.ispartofNuclear Engineering and Technology
dc.rightsopenAccess
dc.titleImpact of oscilloscope connections and bandwidth on signal formation from a SiPM coupled to a LYSO scintillator for gamma spectroscopy
dc.typeArtigo de periódico
dspace.entity.typePublication
ipen.autorSANTOS, ADELSON D. dos
ipen.autorDANIEL ALEXANDRE BAPTISTA BONIFÁCIO
ipen.codigoautor3387
ipen.contributor.ipenauthorDANIEL ALEXANDRE BAPTISTA BONIFÁCIO
ipen.identifier.fi2.6
ipen.identifier.fiCiteScore4.9
ipen.identifier.ipendoc31391
ipen.identifier.iwosWoS
ipen.range.fi1.500 - 2.999
ipen.range.percentilfi75.00 - 100.00
ipen.type.genreArtigo
relation.isAuthorOfPublication895856a8-c404-40cf-9dcf-80e74ad6eff7
relation.isAuthorOfPublication.latestForDiscovery895856a8-c404-40cf-9dcf-80e74ad6eff7
sigepi.autor.atividadeDANIEL ALEXANDRE BAPTISTA BONIFÁCIO:3387:330:N

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
31391.pdf
Tamanho:
5.99 MB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções