Results of process equipment imaging by tomographic gamma scan

dc.contributor.authorHARAGUCHI, MARCIO I.
dc.contributor.authorKIM, HAE Y.
dc.contributor.authorCALVO, WILSON A.P.
dc.coverageInternacionalpt_BR
dc.date.accessioned2019-01-31T16:06:25Z
dc.date.available2019-01-31T16:06:25Z
dc.date.issued2018pt_BR
dc.description.abstractGamma scanning is a nuclear inspection technique widely used for troubleshooting industrial process equipments in refineries and petrochemicals. A radiation source and detector move vertically along the height of the vessel and the radiation readings are used to plot the graph of density profile. In recent years, many improvements have been added to this technique, but essentially the result of gamma scanning still consists of a 1-D density plot. Developed in 2012, the tomographic gamma scan uses image reconstruction techniques to show the result of gamma scan as a 2-D density distribution image. In this work, we present the current status of the technology and the results obtained by applying the technique to real operating process equipment. The results present images that match well with the 1-D density plots obtained by the conventional gamma scan and reveal process and operational problems that has never been visualized before with the traditional technique. The tomographic gamma scan can be immediately applied in practice with low financial investment.pt_BR
dc.format.extent649-654pt_BR
dc.identifier.citationHARAGUCHI, MARCIO I.; KIM, HAE Y.; CALVO, WILSON A.P. Results of process equipment imaging by tomographic gamma scan. <b>Chemical Engineering Transactions</b>, v. 69, p. 649-654, 2018. DOI: <a href="https://dx.doi.org/10.3303/CET1869109">10.3303/CET1869109</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/29424.
dc.identifier.doi10.3303/CET1869109pt_BR
dc.identifier.issn2283-9216pt_BR
dc.identifier.orcidaguardandopt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-4316-8335
dc.identifier.percentilfiSem Percentil
dc.identifier.percentilfiCiteScore35.00
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/29424
dc.identifier.vol69pt_BR
dc.relation.ispartofChemical Engineering Transactionspt_BR
dc.rightsopenAccesspt_BR
dc.subjectimage processing
dc.subjecttomography
dc.subjectgamma radiation
dc.subjectequipment
dc.subjectgamma fuel scanning
dc.subjectnondestructive testing
dc.subjectirradiation
dc.subjectradiation sources
dc.subject.otherelectron scanning
dc.subject.othergamma radiography
dc.subject.othertomography
dc.subject.othergamma radiation
dc.subject.otherdistillation
dc.subject.othergamma sources
dc.subject.otherirradiation
dc.titleResults of process equipment imaging by tomographic gamma scanpt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorWILSON APARECIDO PAREJO CALVO
ipen.codigoautor603
ipen.contributor.ipenauthorWILSON APARECIDO PAREJO CALVO
ipen.date.recebimento19-01pt_BR
ipen.identifier.fiSem F.I.pt_BR
ipen.identifier.fiCiteScore1.1
ipen.identifier.ipendoc25207pt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication39f410f2-b7d6-46e9-95ed-3bc77a28004f
relation.isAuthorOfPublication.latestForDiscovery39f410f2-b7d6-46e9-95ed-3bc77a28004f
sigepi.autor.atividadeCALVO, WILSON A.P.:603:240:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
25207.pdf
Tamanho:
1.02 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções