Application of the OSL technique for beta dosimetry
| dc.contributor.author | PINTO, T.N.O. | pt_BR |
| dc.contributor.author | CECATTI, S.G.P. | pt_BR |
| dc.contributor.author | GRONCHI, C.C. | pt_BR |
| dc.contributor.author | CALDAS, L.V.E. | pt_BR |
| dc.coverage | Internacional | pt_BR |
| dc.date.accessioned | 2014-07-15T13:43:46Z | pt_BR |
| dc.date.accessioned | 2014-07-30T11:48:47Z | |
| dc.date.available | 2014-07-15T13:43:46Z | pt_BR |
| dc.date.available | 2014-07-30T11:48:47Z | |
| dc.date.issued | 2008 | pt_BR |
| dc.description.abstract | In recent years, the optically stimulated luminescence (OSL) technique has been used in personal dosimetry, and aluminum oxide (Al2 O3 : C) has become a very useful material for this technique. The objective of this work is to study the dosimetric characterization of Al2 O3 : C for beta radiation detection using the OSL method. The results obtained show that for monitoring of workers exposed to beta radiation, the technique and the material are useful, but the energy dependence of the OSL response of Al2 O3 : C has to be taken into consideration. | |
| dc.format.extent | 332-334 | pt_BR |
| dc.identifier.citation | PINTO, T.N.O.; CECATTI, S.G.P.; GRONCHI, C.C.; CALDAS, L.V.E. Application of the OSL technique for beta dosimetry. <b>Radiation Measurements</b>, v. 43, p. 332-334, 2008. DOI: <a href="https://dx.doi.org/10.1016/j.radmeas.2007.10.024">10.1016/j.radmeas.2007.10.024</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/5062. | |
| dc.identifier.doi | 10.1016/j.radmeas.2007.10.024 | |
| dc.identifier.issn | 1350-4487 | pt_BR |
| dc.identifier.orcid | https://orcid.org/0000-0002-7362-2455 | |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/5062 | pt_BR |
| dc.identifier.vol | 43 | pt_BR |
| dc.relation.ispartof | Radiation Measurements | pt_BR |
| dc.rights | openAccess | en |
| dc.subject | aluminium oxides | pt_BR |
| dc.subject | beta dosimetry | pt_BR |
| dc.subject | luminescence | pt_BR |
| dc.subject | occupational exposure | pt_BR |
| dc.subject | personnel dosimetry | pt_BR |
| dc.subject | radiation detectors | pt_BR |
| dc.subject | radiation monitoring | pt_BR |
| dc.subject | measuring instruments | pt_BR |
| dc.title | Application of the OSL technique for beta dosimetry | pt_BR |
| dc.type | Artigo de periódico | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | LINDA V. E. CALDAS | |
| ipen.autor | CLAUDIA CARLA GRONCHI | |
| ipen.autor | SONIA GARCIA PEREIRA CECATTI | |
| ipen.autor | TERESA CRISTINA NATHAN OUTEIRO PINTO | |
| ipen.codigoautor | 1495 | |
| ipen.codigoautor | 2924 | |
| ipen.codigoautor | 2793 | |
| ipen.codigoautor | 5959 | |
| ipen.contributor.ipenauthor | LINDA V. E. CALDAS | |
| ipen.contributor.ipenauthor | CLAUDIA CARLA GRONCHI | |
| ipen.contributor.ipenauthor | SONIA GARCIA PEREIRA CECATTI | |
| ipen.contributor.ipenauthor | TERESA CRISTINA NATHAN OUTEIRO PINTO | |
| ipen.date.recebimento | 09-02 | pt_BR |
| ipen.identifier.fi | 1.267 | pt_BR |
| ipen.identifier.ipendoc | 13134 | pt_BR |
| ipen.identifier.iwos | WoS | pt_BR |
| ipen.range.fi | 0.001 - 1.499 | |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | 7f46d4f4-dfd6-4485-a767-10df5b4f4f13 | |
| relation.isAuthorOfPublication | c8d2237c-edb6-44d2-95aa-36385f80d11a | |
| relation.isAuthorOfPublication | 6187a764-7aa8-4a06-85f3-6c8cedef1709 | |
| relation.isAuthorOfPublication | 646df4f9-a12a-4a15-9f52-0cac617beed7 | |
| relation.isAuthorOfPublication.latestForDiscovery | 646df4f9-a12a-4a15-9f52-0cac617beed7 | |
| sigepi.autor.atividade | PINTO, T.N.O.:5959:330:S | pt_BR |
| sigepi.autor.atividade | CECATTI, S.G.P.:2793:330:N | pt_BR |
| sigepi.autor.atividade | GRONCHI, C.C.:2924:330:N | pt_BR |
| sigepi.autor.atividade | CALDAS, L.V.E.:1495:330:N | pt_BR |
Pacote Original
1 - 1 de 1