Study and development of neutron detectors using doped CsI crystals

Carregando...
Imagem de Miniatura

Data

Data de publicação

Orientador

Título da Revista

ISSN da Revista

Título do Volume

É parte de

É parte de

É parte de

RAP Conference Proceedings
Exportar
Mendeley

Projetos de Pesquisa

Unidades Organizacionais

Fascículo

Resumo
The development of new radiation detectors using scintillation crystals, which increase response speed, dose and energy accuracy and, at the same time, the feasibility of simplifying and reducing costs in the production process are always necessary. In the CTR-IPEN laboratory, pure and doped CsI crystals were grown using the Bridgman technique. This work shows the obtained results using a doped CsI scintillator with the converters: Br, Pb, Tl, Li as alpha, beta, gamma and neutron detectors.

Como referenciar
MADI FILHO, TUFIC; PEREIRA, MARIA da C.C.; BERRETTA, JOSE R.; TOMAZ, LUCAS F.; MADI, MIRIAM N. Study and development of neutron detectors using doped CsI crystals. RAP Conference Proceedings, v. 4, p. 117-121, 2019. DOI: 10.37392/RapProc.2019.23. Disponível em: http://repositorio.ipen.br/handle/123456789/31059. Acesso em: 30 Dec 2025.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.