Development of a shielding device for radiotherapy of breast cancer-bearing mice

dc.contributor.authorSILVA, C.R.pt_BR
dc.contributor.authorPEREIRA, S.T.pt_BR
dc.contributor.authorNAPOLITANO, C.M.pt_BR
dc.contributor.authorSOMESSARI, E.S.R.pt_BR
dc.contributor.authorRIBEIRO, M.S.pt_BR
dc.coverageNacionalpt_BR
dc.date.accessioned2020-12-07T14:41:10Z
dc.date.available2020-12-07T14:41:10Z
dc.date.issued2020pt_BR
dc.description.abstractBreast cancer is the fifth most common cause of death worldwide. Currently, one of the standard treatments for breast cancer is radiation therapy (RT). On the other hand, mouse models have been used in pre-clinical studies for breast cancer RT, requiring dedicated shielding to exposure the breast region. In this work, we considered the values of the lead attenuation coefficient and the material tenth reducing layer for 60Co gamma radiation and developed a lead shielding device for breast cancer-bearing mice to be exposed to localized breast RT. Five-kg of lead were heated to of 340ºC and inserted into an aluminum mold previously adjusted to the dimensions of the device. After solidification, the device was shaped into a cylinder with dimension of 14 x 15 x 7 cm (height x width x thickness, respectively). A round cut-out for breast exposure of 1 cm in diameter was made at 5 cm from the basis of the device. For shielding device validation, we performed calibrations to establish a dose of 10 Gy to the target volume. Fifteen CaSO4:Dy thermoluminescent dosimeters were distributed inside the conical tube to mimic the mouse position inside the shielding. The shielding device was placed at a fixed distance of 10 cm from the target for optimal exposure time. After irradiation, the dosimeters were read using a thermoluminescent reader. According to our results, we were able to develop a body-shielding device that assured the required dose for RT of breast cancer in mice.pt_BR
dc.format.extent1-9pt_BR
dc.identifier.citationSILVA, C.R.; PEREIRA, S.T.; NAPOLITANO, C.M.; SOMESSARI, E.S.R.; RIBEIRO, M.S. Development of a shielding device for radiotherapy of breast cancer-bearing mice. <b>Brazilian Journal of Radiation Sciences</b>, v. 8, n. 1, p. 1-9, 2020. DOI: <a href="https://dx.doi.org/10.15392/bjrs.v8i1A.1164">10.15392/bjrs.v8i1A.1164</a>. Disponível em: http://200.136.52.105/handle/123456789/31597.
dc.identifier.doi10.15392/bjrs.v8i1A.1164pt_BR
dc.identifier.fasciculo1pt_BR
dc.identifier.issn2319-0612pt_BR
dc.identifier.orcid0000-0002-4203-1134pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-4203-1134
dc.identifier.percentilfiSem Percentilpt_BR
dc.identifier.urihttp://200.136.52.105/handle/123456789/31597
dc.identifier.vol8pt_BR
dc.relation.ispartofBrazilian Journal of Radiation Sciencespt_BR
dc.rightsopenAccesspt_BR
dc.sourceInternational Joint Conference Radio, September 16-20, 2019, São Paulo, SPpt_BR
dc.subjectabsorbed radiation doses
dc.subjectcobalt 60
dc.subjectgamma radiation
dc.subjectionizing radiations
dc.subjectlead
dc.subjectmammary glands
dc.subjectmice
dc.subjectneoplasms
dc.subjectradiotherapy
dc.subjectshielding
dc.subjectthermoluminescent dosemeters
dc.titleDevelopment of a shielding device for radiotherapy of breast cancer-bearing micept_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorSAULO DE TOLEDO PEREIRA
ipen.autorMARTHA SIMOES RIBEIRO
ipen.autorELIZABETH SEBASTIANA RIBEIRO SOMESSARI
ipen.autorCELIA MARINA NAPOLITANO
ipen.autorCAMILA RAMOS SILVA
ipen.codigoautor14728
ipen.codigoautor574
ipen.codigoautor1544
ipen.codigoautor1059
ipen.codigoautor11642
ipen.contributor.ipenauthorSAULO DE TOLEDO PEREIRA
ipen.contributor.ipenauthorMARTHA SIMOES RIBEIRO
ipen.contributor.ipenauthorELIZABETH SEBASTIANA RIBEIRO SOMESSARI
ipen.contributor.ipenauthorCELIA MARINA NAPOLITANO
ipen.contributor.ipenauthorCAMILA RAMOS SILVA
ipen.date.recebimento20-12
ipen.identifier.fiSem F.I.pt_BR
ipen.identifier.ipendoc27369pt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication66ffed91-aa19-447b-ba42-d90487125c03
relation.isAuthorOfPublication36215a53-0150-4910-91d7-9559717b62d7
relation.isAuthorOfPublication155e1a85-0635-407b-920c-00af43266aca
relation.isAuthorOfPublication2e92f7af-fc42-4993-be8b-8d3201b2d320
relation.isAuthorOfPublication7b89c9af-427d-4f2a-bb3d-1f6252c548c2
relation.isAuthorOfPublication.latestForDiscovery7b89c9af-427d-4f2a-bb3d-1f6252c548c2
sigepi.autor.atividadeRIBEIRO, M.S.:574:920:Npt_BR
sigepi.autor.atividadeSOMESSARI, E.S.R.:1544:220:Npt_BR
sigepi.autor.atividadeNAPOLITANO, C.M.:1059:220:Npt_BR
sigepi.autor.atividadePEREIRA, S.T.:14728:920:Npt_BR
sigepi.autor.atividadeSILVA, C.R.:11642:920:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
27369.pdf
Tamanho:
745.21 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções