Stability of fatigued and aged ZTA compared to 3Y-TZP and Al2O3 ceramic systems

dc.contributor.authorBENALCAZAR JALKH, ERNESTO B.pt_BR
dc.contributor.authorBERGAMO, EDMARA T.P.pt_BR
dc.contributor.authorCAMPOS, TIAGO M.B.pt_BR
dc.contributor.authorARAUJO-JUNIOR, EVERARDO N.S. dept_BR
dc.contributor.authorLOPES, ADOLFO C.O.pt_BR
dc.contributor.authorTEBCHERANI, SERGIO M.pt_BR
dc.contributor.authorYAMAGUCHI, SATOSHIpt_BR
dc.contributor.authorGENOVA, LUIS A.pt_BR
dc.contributor.authorGIERTHMUEHLEN, PETRA C.pt_BR
dc.contributor.authorWITEK, LUKASZpt_BR
dc.contributor.authorCOELHO, PAULO G.pt_BR
dc.contributor.authorBONFANTE, ESTEVAM A.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2022-12-14T17:47:24Z
dc.date.available2022-12-14T17:47:24Z
dc.date.issued2022pt_BR
dc.description.abstractTo evaluate the effect of fatigue and aging on the crystalline content and reliability of a zirconia-toughened-alumina (ZTA) composite compared to its individual counterpart materials (3Y-TZP and Al2O3). Thirty-six disc-shaped specimens per group were obtained to comply with ISO 6872:2015. Crystalline content, microstructure and reliability of experimental groups were evaluated in four stages: 1) immediate; 2) aged; 3) fatigued; 4) aged + fatigue. Aging was performed in autoclave and Step-Stress-Accelerated-Life-Testing (SSALT) was performed using three stress profiles. Weibull statistics were used to determine Weibull parameters and life-expectancy. A significant increase in monoclinic phase in 3Y-TZP was observed after aging (19.31%), fatigue (17.88%) and aging + fatigue (55.81%), while ZTA evidenced minimal variation among all conditions (<5.69%). 3Y-TZP presented higher reliability than ZTA at 300 and 500 MPa, and ZTA outperformed Al2O3 at the same stress missions. None of the ceramics yielded acceptable reliability at 800 MPa. A higher characteristic strength was observed for 3Y-TZP, followed by ZTA and Al2O3. While after aging ZTA and Al2O3 remained stable, 3Y-TZP exhibited a significant increase in the characteristic stress. Aging did not affect the reliability of ZTA and Al2O3. 3Y-TZP demonstrated an increase in monoclinic content and characteristic strength after aging.pt_BR
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)pt_BR
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)pt_BR
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)pt_BR
dc.description.sponsorshipIDFAPESP: 12/19078-7; 21/06730-7; 16/18818-8; 22/07157-1; 18/03072-6; 19/00452-5; 19/08693-1; 21/08018-2; 16/17793-1; 17/19362-0pt_BR
dc.description.sponsorshipIDCNPq: 307255/2021-2pt_BR
dc.description.sponsorshipIDCAPES: 001pt_BR
dc.format.extent1-9pt_BR
dc.identifier.citationBENALCAZAR JALKH, ERNESTO B.; BERGAMO, EDMARA T.P.; CAMPOS, TIAGO M.B.; ARAUJO-JUNIOR, EVERARDO N.S. de; LOPES, ADOLFO C.O.; TEBCHERANI, SERGIO M.; YAMAGUCHI, SATOSHI; GENOVA, LUIS A.; GIERTHMUEHLEN, PETRA C.; WITEK, LUKASZ; COELHO, PAULO G.; BONFANTE, ESTEVAM A. Stability of fatigued and aged ZTA compared to 3Y-TZP and Al2O3 ceramic systems. <b>Journal of the Mechanical Behavior of Biomedical Materials</b>, v. 135, p. 1-9, 2022. DOI: <a href="https://dx.doi.org/10.1016/j.jmbbm.2022.105451">10.1016/j.jmbbm.2022.105451</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/33438.
dc.identifier.doi10.1016/j.jmbbm.2022.105451pt_BR
dc.identifier.issn1751-6161pt_BR
dc.identifier.orcid0000-0002-5172-5082pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-5172-5082
dc.identifier.percentilfi47.9pt_BR
dc.identifier.percentilfiCiteScore70.33pt_BR
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/33438
dc.identifier.vol135pt_BR
dc.relation.ispartofJournal of the Mechanical Behavior of Biomedical Materialspt_BR
dc.rightsopenAccesspt_BR
dc.subjectmicrostructure
dc.subjectaging
dc.subjectreliability
dc.subjectzirconium
dc.subjectaluminates
dc.subjectfatigue
dc.subjectfatigue
dc.titleStability of fatigued and aged ZTA compared to 3Y-TZP and Al2O3 ceramic systemspt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorLUIS ANTONIO GENOVA
ipen.codigoautor320
ipen.contributor.ipenauthorLUIS ANTONIO GENOVA
ipen.date.recebimento22-12
ipen.identifier.fi3.9pt_BR
ipen.identifier.fiCiteScore6.8pt_BR
ipen.identifier.ipendoc29072pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.identifier.ods7
ipen.identifier.ods9
ipen.identifier.ods12
ipen.range.fi3.000 - 4.499
ipen.range.percentilfi25.00 - 49.99
ipen.type.genreArtigo
relation.isAuthorOfPublicatione7af24e8-0db9-49d2-8caf-92fd57c2686b
relation.isAuthorOfPublication.latestForDiscoverye7af24e8-0db9-49d2-8caf-92fd57c2686b
sigepi.autor.atividadeGENOVA, LUIS A.:320:720:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
29072.pdf
Tamanho:
5.54 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções