Performance of a prototype of an extrapolation minichamber in various radiation beams

dc.contributor.authorOLIVEIRA, M.L.pt_BR
dc.contributor.authorCALDAS, L.V.E.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2014-07-15T13:46:01Zpt_BR
dc.date.accessioned2014-07-30T11:47:21Z
dc.date.available2014-07-15T13:46:01Zpt_BR
dc.date.available2014-07-30T11:47:21Z
dc.date.issued2007pt_BR
dc.description.abstractAn extrapolation minichamber was developed for measuring doses from weakly penetrating types of radiation. The chamber was tested at the radiotherapeutic dose level in a beam from a 90Sr+90Y check source, in a beam from a plane 90Sr+90Y ophthalmic applicator, and in several reference beams from an X-ray tube. Saturation, ion collection efficiency, stabilization time, extrapolation curves, linearity of chamber response vs. air kerma rate, and dependences of the response on the energy and irradiation angle were characterized. The results are satisfactory; they show that the chamber can be used in the dosimetry of 90Sr+90Y beta particles and low-energy X-ray beams.
dc.format.extent975-979pt_BR
dc.identifier.citationOLIVEIRA, M.L.; CALDAS, L.V.E. Performance of a prototype of an extrapolation minichamber in various radiation beams. <b>Applied Radiation and Isotopes</b>, v. 65, n. 8, p. 975-979, 2007. DOI: <a href="https://dx.doi.org/10.1016/j.apradiso.2007.03.021">10.1016/j.apradiso.2007.03.021</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/5253.
dc.identifier.doi10.1016/j.apradiso.2007.03.021
dc.identifier.fasciculo8pt_BR
dc.identifier.issn0969-8043pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/5253pt_BR
dc.identifier.vol65pt_BR
dc.relation.ispartofApplied Radiation and Isotopespt_BR
dc.rightsopenAccessen
dc.subjectbeamspt_BR
dc.subjectbeta dosimetrypt_BR
dc.subjectcalibration standardspt_BR
dc.subjectdosimetrypt_BR
dc.subjectextrapolation chamberspt_BR
dc.subjectkermapt_BR
dc.subjectradiation dosespt_BR
dc.subjectstrontium 90pt_BR
dc.subjectx radiationpt_BR
dc.subjectx-ray tubespt_BR
dc.subjectyttrium 90pt_BR
dc.titlePerformance of a prototype of an extrapolation minichamber in various radiation beamspt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorLINDA V. E. CALDAS
ipen.autorMERCIA LIANE DE OLIVEIRA
ipen.codigoautor1495
ipen.codigoautor2939
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.contributor.ipenauthorMERCIA LIANE DE OLIVEIRA
ipen.date.recebimento07-09pt_BR
ipen.identifier.fi1.008pt_BR
ipen.identifier.ipendoc11833pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi0.001 - 1.499
ipen.type.genreArtigo
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublication09c8aa38-12ff-4a5e-9221-4e32244d9f17
relation.isAuthorOfPublication.latestForDiscovery09c8aa38-12ff-4a5e-9221-4e32244d9f17
sigepi.autor.atividadeOLIVEIRA, M.L.:2939:-1:Spt_BR
sigepi.autor.atividadeCALDAS, L.V.E.:1495:28:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
11833.pdf
Tamanho:
275.22 KB
Formato:
Adobe Portable Document Format

Coleções