Heterogeneous physical phantom for I-125 dose measurements and dose-to-medium determination

dc.contributor.authorANTUNES, PAULA C.G.
dc.contributor.authorSIQUEIRA, PAULO de T.D.
dc.contributor.authorSHORTO, JULIAN M.B.
dc.contributor.authorYORIYAZ, HELIO
dc.coverageInternacional
dc.date.accessioned2024-04-04T16:42:25Z
dc.date.available2024-04-04T16:42:25Z
dc.date.issued2024
dc.description.abstractPURPOSE: In this paper we present a further step in the implementation of a physical phantom designed to generate sets of “true”independent reference data as requested by TG-186, intending to address and mitigate the scarcity of experimental studies on brachytherapy (BT) validation in heterogeneous media. To achieve this, we incorporated well-known heterogeneous materials into the phantom in order to perform measurements of 125I dose distribution. The work aims to experimentally validate Monte Carlo (MC) calculations based on MBDCA and determine the conversion factors from LiF response to absorbed dose in different media, using cavity theory. METHODS AND MATERIALS: The physical phantom was adjusted to incorporate tissue equivalent materials, such as: adipose tissue, bone, breast and lung with varying thickness. MC calculations were performed using MCNP6.2 code to calculate the absorbed dose in the LiF and the dose conversion factors (DCF). RESULTS: The proposed heterogeneous phantom associated with the experimental procedure carried out in this work yielded accurate dose data that enabled the conversion of the LiF responses into absorbed dose to medium. The results showed a maximum uncertainty of 6.92 % ( k = 1), which may be considered excellent for dosimetry with low-energy BT sources. CONCLUSIONS: The presented heterogeneous phantom achieves the required precision in dose evaluations due to its easy reproducibility in the experimental setup. The obtained results support the dose conversion methodology for all evaluated media. The experimental validation of the DCF in different media holds great significance for clinical procedures, as it can be applied to other tissues, including water, which remains a widely utilized reference medium in clinical practice.
dc.format.extent73-84
dc.identifier.citationANTUNES, PAULA C.G.; SIQUEIRA, PAULO de T.D.; SHORTO, JULIAN M.B.; YORIYAZ, HELIO. Heterogeneous physical phantom for I-125 dose measurements and dose-to-medium determination. <b>Brachytherapy</b>, v. 23, n. 1, p. 73-84, 2024. DOI: <a href="https://dx.doi.org/10.1016/j.brachy.2023.08.007">10.1016/j.brachy.2023.08.007</a>. Disponível em: https://repositorio.ipen.br/handle/123456789/48011.
dc.identifier.doi10.1016/j.brachy.2023.08.007
dc.identifier.fasciculo1
dc.identifier.issn1538-4721
dc.identifier.orcidhttps://orcid.org/0000-0003-4817-5275
dc.identifier.orcidhttps://orcid.org/0000-0003-4023-236X
dc.identifier.percentilfi32.5
dc.identifier.percentilfiCiteScore47.50
dc.identifier.urihttps://repositorio.ipen.br/handle/123456789/48011
dc.identifier.vol23
dc.relation.ispartofBrachytherapy
dc.rightsopenAccess
dc.subjectphantoms
dc.subjectdosimetry
dc.subjectbrachytherapy
dc.subjectiodine 125
dc.subjectmonte carlo method
dc.subjectdose rates
dc.subjectalgorithms
dc.subjectradiation dose distributions
dc.subjectlithium fluorides
dc.titleHeterogeneous physical phantom for I-125 dose measurements and dose-to-medium determination
dc.typeArtigo de periódico
dspace.entity.typePublication
ipen.autorPAULA CRISTINA GUIMARÃES ANTUNES
ipen.autorPAULO DE TARSO DALLEDONE SIQUEIRA
ipen.autorJULIAN MARCO BARBOSA SHORTO
ipen.autorHELIO YORIYAZ
ipen.codigoautor5958
ipen.codigoautor968
ipen.codigoautor9690
ipen.codigoautor80
ipen.contributor.ipenauthorPAULA CRISTINA GUIMARÃES ANTUNES
ipen.contributor.ipenauthorPAULO DE TARSO DALLEDONE SIQUEIRA
ipen.contributor.ipenauthorJULIAN MARCO BARBOSA SHORTO
ipen.contributor.ipenauthorHELIO YORIYAZ
ipen.identifier.fi1.7
ipen.identifier.fiCiteScore3.4
ipen.identifier.ipendoc30038
ipen.identifier.iwosWoS
ipen.range.fi1.500 - 2.999
ipen.range.percentilfi25.00 - 49.99
ipen.type.genreArtigo
relation.isAuthorOfPublication6011fbed-3deb-4798-8497-135bee30261a
relation.isAuthorOfPublication24db5afe-fc9a-4cc0-9be3-2c5035796315
relation.isAuthorOfPublication91a9cbb6-cd24-480c-a65d-dd1c309a1622
relation.isAuthorOfPublication93102dac-f89d-4743-b6ea-5158708cbb92
relation.isAuthorOfPublication.latestForDiscovery6011fbed-3deb-4798-8497-135bee30261a
sigepi.autor.atividadePAULA CRISTINA GUIMARÃES ANTUNES:5958:420:S
sigepi.autor.atividadePAULO DE TARSO DALLEDONE SIQUEIRA:968:420:N
sigepi.autor.atividadeJULIAN MARCO BARBOSA SHORTO:9690:420:N
sigepi.autor.atividadeHELIO YORIYAZ:80:420:N

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
30038.pdf
Tamanho:
3.03 MB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções