Performance evaluation of a new dosimetric system for lens dosimetry made using 3D printing

dc.contributor.authorNASCIMENTO, G.G.
dc.contributor.authorRODRIGUES JUNIOR, O.
dc.contributor.authorSAVI, M.
dc.contributor.authorVILLANI, D.
dc.contributor.authorPOTIENS, M.P.A.
dc.contributor.editorPESSANHA, SOFIA
dc.contributor.editorMANSO, MARTA
dc.coverageInternacional
dc.creator.eventoINTERNATIONAL SYMPOSIA ON RADIATION PHYSICS, 19th
dc.date.accessioned2025-12-23T18:57:31Z
dc.date.available2025-12-23T18:57:31Z
dc.date.eventoSeptember 1-5, 2024
dc.description.abstractTechnology advances in the health sector make it possible for medical radiology services, especially interventional radiology, to be more requested by doctors, which results in a significant increase in the number of procedures performed and the number of patients and occupationally exposed individuals (OEI) [1]. This increase in exposure of OEIs has caused concern regarding the exposure of the lens to ionizing radiation, since this tissue is considered a tissue with high radiosensitivity. This concern about exposing the lens region to ionizing radiation has existed for more than 10 years [2], considering these concerns, in 1950 the International Commission on Radiological Protection (ICRP) listed the lens of the eye as a critical organ [3]. In 2011, ICRP recommended a reduction in the occupational dose limit for the lens region from 150 mSv/year to 20 mSv/year [4]. In addition to technology advances and optimization of procedures used to reduce doses and risks that may affect the patient in interventional radiology applications, it is necessary to have a monitoring system suitable for the occupation. This monitoring is carried out using a dosimeter, which is part of a dosimetric system composed of a dosimeter holder, detector and a reading system compatible with the detector. In this work, chip-shaped LiF:Mg,Ti thermoluminescent detectors, commercially known as TLD-100, were used. For this study, a dosimeter holder produced in 3D printing was developed for use in eye lens dosimetry. A Raise 3D printer model Pro2 was used, which works using the FFF technique, the dosimeter holders were made from PLA and ABS material. The dosimeter holder has space to accommodate up to two chip-shaped detectors and has a support that fits with the glasses stem. The irradiations were carried out using Pantak/Seifert X-ray equipment, model Isovolt 60 HS. The N-100 radioprotection quality was used, with an energy of 83 keV, within the energy range between 40 and 120 keV, the quality used is within the range used in interventional radiology. The tests were conducted in accordance with the recommendations of ISO 12794:2000 [5]. From a dosimetric point of view, the type of material used to manufacture the dosimeter holders did not present significant differences. However, dosimeter holders made of PLA showed better resistance during the procedures.
dc.event.siglaISRP
dc.format.extent153-153
dc.identifier.citationNASCIMENTO, G.G.; RODRIGUES JUNIOR, O.; SAVI, M.; VILLANI, D.; POTIENS, M.P.A. Performance evaluation of a new dosimetric system for lens dosimetry made using 3D printing. In: PESSANHA, SOFIA (ed.); MANSO, MARTA (ed.). In: INTERNATIONAL SYMPOSIA ON RADIATION PHYSICS, 19th, September 1-5, 2024, Lisbon, Portugal. <b>Abstract...</b> Lisbon, Portugal: Universidade Nova de Lisboa - Faculdade de Ciências e Tecnologia, 2024. p. 153-153. Disponível em: https://repositorio.ipen.br/handle/123456789/48971.
dc.identifier.orcidhttps://orcid.org/0000-0002-6704-1910
dc.identifier.orcidhttps://orcid.org/0000-0002-4049-6720
dc.identifier.urihttps://repositorio.ipen.br/handle/123456789/48971
dc.language.isoeng
dc.localLisbon, Portugal
dc.local.eventoLisbon, Portugal
dc.publisherUniversidade Nova de Lisboa - Faculdade de Ciências e Tecnologia
dc.rightsopenAccess
dc.titlePerformance evaluation of a new dosimetric system for lens dosimetry made using 3D printing
dc.typeResumo de eventos científicos
dspace.entity.typePublication
ipen.autorGABRIEL GOMES DO NASCIMENTO
ipen.autorORLANDO RODRIGUES JUNIOR
ipen.autorDANIEL VILLANI
ipen.autorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.codigoautor14794
ipen.codigoautor322
ipen.codigoautor12762
ipen.codigoautor346
ipen.contributor.ipenauthorGABRIEL GOMES DO NASCIMENTO
ipen.contributor.ipenauthorORLANDO RODRIGUES JUNIOR
ipen.contributor.ipenauthorDANIEL VILLANI
ipen.contributor.ipenauthorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.event.datapadronizada2024
ipen.identifier.ipendoc31031
ipen.notas.internasAbstract
ipen.type.genreResumo
relation.isAuthorOfPublicationef601e21-998c-4d4d-9aee-c0f8dbc84c10
relation.isAuthorOfPublicationf72d59d1-f942-442a-b16e-8b0ba0e2b671
relation.isAuthorOfPublication26698252-02e7-4d43-8ffb-edaf9f863fa2
relation.isAuthorOfPublication30f213ae-321d-4d51-8763-0a2585255fb9
relation.isAuthorOfPublication.latestForDiscoveryef601e21-998c-4d4d-9aee-c0f8dbc84c10
sigepi.autor.atividadeGABRIEL GOMES DO NASCIMENTO:14794:330:N
sigepi.autor.atividadeORLANDO RODRIGUES JUNIOR:322:330:N
sigepi.autor.atividadeDANIEL VILLANI:12762:330:N
sigepi.autor.atividadeMARIA DA PENHA ALBUQUERQUE POTIENS:346:330:N

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
31031.pdf
Tamanho:
83.75 KB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: