In silico dosimetry of low-dose rate brachytherapy using radioactive nanoparticles

dc.contributor.authorSENIWAL, BALJEETpt_BR
dc.contributor.authorFREITAS, LUCAS F.pt_BR
dc.contributor.authorMENDES, BRUNO M.pt_BR
dc.contributor.authorLUGAO, ADEMAR B.pt_BR
dc.contributor.authorKATTI, KATTESH V.pt_BR
dc.contributor.authorFONSECA, TELMA C.F.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2021-03-22T15:34:10Z
dc.date.available2021-03-22T15:34:10Z
dc.date.issued2021pt_BR
dc.description.abstractPurpose. Nanoparticles (NPs) with radioactive atoms incorporated within the structure of the NP or bound to its surface, functionalized with biomolecules are reported as an alternative to low-dose-rate seed-based brachytherapy. In this study, authors report a mathematical dosimetric study on low-dose rate brachytherapy using radioactive NPs. Method. Single-cell dosimetry was performed by calculating cellular S-values for spherical cell model using Au-198, Pd-103 and Sm-153 NPs. The cell survival and tumor volume versus time curves were calculated and compared to the experimental studies on radiotherapeutic efficiency of radioactive NPs published in the literature. Finally, the radiotherapeutic efficiency of Au-198, Pd-103 and Sm-153 NPs was tested for variable: administered radioactivity, tumor volume and tumor cell type. Result. At the cellular level Sm-153 presented the highest S-value, followed by Pd-103 and Au-198. The calculated cell survival and tumor volume curves match very well with the published experimental results. It was found that Au-198 and Sm-153 can effectively treat highly aggressive, large tumor volumes with low radioactivity. Conclusion. The accurate knowledge of uptake rate, washout rate of NPs, radio-sensitivity and tumor repopulation rate is important for the calculation of cell survival curves. Self-absorption of emitted radiation and dose enhancement due to AuNPs must be considered in the calculations. Selection of radionuclide for radioactive NP must consider size of tumor, repopulation rate and radiosensitivity of tumor cells. Au-198 NPs functionalized with Mangiferin are a suitable choice for treating large, radioresistant and rapidly growing tumors.pt_BR
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)pt_BR
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de Minas Gerais (FAPEMIG)pt_BR
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)pt_BR
dc.description.sponsorshipIDCNPq: 450493/2019-9pt_BR
dc.description.sponsorshipIDFAPEMIG: APQ-00083-18; 2070.01.0002992/2018-30pt_BR
dc.description.sponsorshipIDFAPESP: 18/15598-2pt_BR
dc.format.extent1-13pt_BR
dc.identifier.citationSENIWAL, BALJEET; FREITAS, LUCAS F.; MENDES, BRUNO M.; LUGAO, ADEMAR B.; KATTI, KATTESH V.; FONSECA, TELMA C.F. In silico dosimetry of low-dose rate brachytherapy using radioactive nanoparticles. <b>Physics in Medicine and Biology</b>, v. 66, n. 4, p. 1-13, 2021. DOI: <a href="https://dx.doi.org/10.1088/1361-6560/abd671">10.1088/1361-6560/abd671</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/31932.
dc.identifier.doi10.1088/1361-6560/abd671pt_BR
dc.identifier.fasciculo4pt_BR
dc.identifier.issn0031-9155pt_BR
dc.identifier.orcid0000-0002-1737-3191pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-1737-3191
dc.identifier.percentilfi59.98pt_BR
dc.identifier.percentilfiCiteScore83.50
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/31932
dc.identifier.vol66pt_BR
dc.relation.ispartofPhysics in Medicine and Biologypt_BR
dc.rightsopenAccesspt_BR
dc.subjectnanoparticles
dc.subjectradioactive materials
dc.subjectradioactivity
dc.subjectbrachytherapy
dc.subjectdose rates
dc.subjectlow dose irradiation
dc.subjectdosimetry
dc.subjectradiotherapy
dc.subjectnanomaterials
dc.subjectneoplasms
dc.titleIn silico dosimetry of low-dose rate brachytherapy using radioactive nanoparticlespt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorADEMAR BENEVOLO LUGAO
ipen.autorLUCAS FREITAS DE FREITAS
ipen.codigoautor339
ipen.codigoautor14818
ipen.contributor.ipenauthorADEMAR BENEVOLO LUGAO
ipen.contributor.ipenauthorLUCAS FREITAS DE FREITAS
ipen.date.recebimento21-03
ipen.identifier.fi4.174pt_BR
ipen.identifier.fiCiteScore6.6
ipen.identifier.ipendoc27703pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi3.000 - 4.499
ipen.range.percentilfi50.00 - 74.99
ipen.type.genreArtigo
relation.isAuthorOfPublication99ac24c5-2ae1-465a-a6f2-40b4d9af6af7
relation.isAuthorOfPublication05be75ae-89a2-47f4-a13a-7723b50a6bd0
relation.isAuthorOfPublication.latestForDiscovery05be75ae-89a2-47f4-a13a-7723b50a6bd0
sigepi.autor.atividadeLUGAO, ADEMAR B.:339:740:Npt_BR
sigepi.autor.atividadeFREITAS, LUCAS F.:14818:740:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
27703.pdf
Tamanho:
978.2 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções