MCMEG

dc.contributor.authorFONSECA, T.C.F.pt_BR
dc.contributor.authorANTUNES, P.C.G.pt_BR
dc.contributor.authorBELO, M.C.L.pt_BR
dc.contributor.authorBASTOS, F.pt_BR
dc.contributor.authorCAMPOS, T.P.pt_BR
dc.contributor.authorGERALDO, J.M.pt_BR
dc.contributor.authorMENDES, A.M.pt_BR
dc.contributor.authorMENDES, B.M.pt_BR
dc.contributor.authorPAIXÃO, L.pt_BR
dc.contributor.authorSANTANA, P.C.pt_BR
dc.contributor.authorSENIWAL, B.pt_BR
dc.contributor.authorSQUAIR, P.L.pt_BR
dc.contributor.authorYORIYAZ, H.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2019-12-17T13:56:07Z
dc.date.available2019-12-17T13:56:07Z
dc.date.issued2020pt_BR
dc.description.abstractThe improvement of the Monte Carlo (MC) community skills on computational simulations in Medical Physics is crucial to the field of radiotherapy as well as radiology. The Monte Carlo Modelling Expert Group (MCMEG) is an expert network specialized in MC radiation transport modelling and simulation applied to the radiation protection and dosimetry research fields. The MCMEG addressed a multigroup dosimetric intercomparison exercise for modelling and simulating a case of prostate radiation therapy (RT) protocol. This intercomparison was launched in order to obtain the dose distribution in the prostate target volume and in the neighboring organs. Dose assessments were achieved by using TLDs. A protocol using two pair of parallel-opposed fields were planned and performed with Alderson-Rando Pelvic Phantom. The assessed organs at risk were the urinary bladder, rectum and right and left femur heads. The RT simulations were performed using the MCNPx, MCNP6 and egs++ and BEAMnrc/DOSXYZnrc modules of EGSnrc Monte Carlo codes. The dose to the target volume, mean doses and standard deviation in the organs at risk, and dose volume data were computed. A comparison between the simulated results and the experimental values obtained from TLD measurements was made. In some cases the results obtained using MC simulations showed large deviations in comparison to the results obtained from the TLD measurements and these variations can be explained by the difficulties in the modelling of the geometry, selection of MC parameters required for the simulations and the statistical errors and inaccuracies in experimental measurements. Even though, the exercise has been a great opportunity for the MC groups to learn and share the main difficulties found during the modelling and the analysis of the results. Concerned to the obtained variations, the MCMEG team consider that this was expected for the level of complexity of the exercise and must be studied by the MC groups.pt_BR
dc.format.extent1-7pt_BR
dc.identifier.citationFONSECA, T.C.F.; ANTUNES, P.C.G.; BELO, M.C.L.; BASTOS, F.; CAMPOS, T.P.; GERALDO, J.M.; MENDES, A.M.; MENDES, B.M.; PAIXÃO, L.; SANTANA, P.C.; SENIWAL, B.; SQUAIR, P.L.; YORIYAZ, H. MCMEG: intercomparison exercise on prostate radiotherapy dose assessment. <b>Radiation Physics and Chemistry</b>, v. 167, p. 1-7, 2020. DOI: <a href="https://dx.doi.org/10.1016/j.radphyschem.2019.04.045">10.1016/j.radphyschem.2019.04.045</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/30449.
dc.identifier.doi10.1016/j.radphyschem.2019.04.045pt_BR
dc.identifier.issn0969-806Xpt_BR
dc.identifier.orcid0000-0003-4023-236Xpt_BR
dc.identifier.orcidhttps://orcid.org/0000-0003-4023-236X
dc.identifier.percentilfi66.43pt_BR
dc.identifier.percentilfiCiteScore72.00
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/30449
dc.identifier.vol167pt_BR
dc.relation.ispartofRadiation Physics and Chemistrypt_BR
dc.rightsopenAccesspt_BR
dc.sourceInternational Symposium on Radiation Physics, 14th, October 7-11, 2018, Córdoba, Argentinapt_BR
dc.subjectmonte carlo method
dc.subjectsimulation
dc.subjectradiotherapy
dc.subjectprostate
dc.subjectirradiation
dc.subjectformation damage
dc.subjectphantoms
dc.subjectinterlaboratory comparisons
dc.subjectradiation doses
dc.subjecttherapy
dc.subjectradiology
dc.titleMCMEGpt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorHELIO YORIYAZ
ipen.autorPAULA CRISTINA GUIMARÃES ANTUNES
ipen.codigoautor80
ipen.codigoautor5958
ipen.contributor.ipenauthorHELIO YORIYAZ
ipen.contributor.ipenauthorPAULA CRISTINA GUIMARÃES ANTUNES
ipen.date.recebimento19-12
ipen.identifier.fi2.858pt_BR
ipen.identifier.fiCiteScore3.8
ipen.identifier.ipendoc26469pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.identifier.ods3
ipen.range.fi1.500 - 2.999
ipen.range.percentilfi50.00 - 74.99
ipen.subtitulointercomparison exercise on prostate radiotherapy dose assessmentpt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication93102dac-f89d-4743-b6ea-5158708cbb92
relation.isAuthorOfPublication6011fbed-3deb-4798-8497-135bee30261a
relation.isAuthorOfPublication.latestForDiscovery6011fbed-3deb-4798-8497-135bee30261a
sigepi.autor.atividadeYORIYAZ, H.:80:420:Npt_BR
sigepi.autor.atividadeANTUNES, P.C.G.:5958:420:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
26469.pdf
Tamanho:
802.43 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções