A new extended-length parallel-plate ionization chamber
| dc.contributor.author | MAIA, A.F. | pt_BR |
| dc.contributor.author | CALDAS, L.V.E. | pt_BR |
| dc.coverage | Internacional | pt_BR |
| dc.date.accessioned | 2014-07-15T13:49:12Z | pt_BR |
| dc.date.accessioned | 2014-07-30T11:50:44Z | |
| dc.date.available | 2014-07-15T13:49:12Z | pt_BR |
| dc.date.available | 2014-07-30T11:50:44Z | |
| dc.date.issued | 2005 | pt_BR |
| dc.description.abstract | A special parallel-plate ionization chamber was developed. The motivation for the construction of this new chamber was mainly to fulfil the need of a reference system for computed tomography standard beams in the Calibration Laboratory of IPEN. However, the chamber was tested also in standard radiation beams of mammography and conventional diagnostic radiology. The chamber was manufactured at the institute workshop, as simply and cheaply as possible. Its design differs from the common ionization chambers used in dosimetric procedures of computed tomography equipment, because it is a parallelplate chamber instead of a cylindrical chamber. However, its dimensions and sensitive volume are very similar to those of a commercial pencil ionization chamber. The new ionization chamber was submitted to several characterization and quality control tests, showing its very good performance. | |
| dc.format.extent | 3837-3847 | pt_BR |
| dc.identifier.citation | MAIA, A.F.; CALDAS, L.V.E. A new extended-length parallel-plate ionization chamber. <b>Physics in Medicine and Biology</b>, v. 50, p. 3837-3847, 2005. DOI: <a href="https://dx.doi.org/10.1088/0031-9155/50/16/012">10.1088/0031-9155/50/16/012</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/5536. | |
| dc.identifier.doi | 10.1088/0031-9155/50/16/012 | |
| dc.identifier.issn | 0031-9155 | pt_BR |
| dc.identifier.orcid | https://orcid.org/0000-0002-7362-2455 | |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/5536 | pt_BR |
| dc.identifier.vol | 50 | pt_BR |
| dc.relation.ispartof | Physics in Medicine and Biology | pt_BR |
| dc.rights | openAccess | en |
| dc.subject | ionization chambers | pt_BR |
| dc.subject | computerized tomography | pt_BR |
| dc.subject | cylindrical configuration | pt_BR |
| dc.subject | quality control | pt_BR |
| dc.subject | performance | pt_BR |
| dc.subject | calibration | pt_BR |
| dc.title | A new extended-length parallel-plate ionization chamber | pt_BR |
| dc.type | Artigo de periódico | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | LINDA V. E. CALDAS | |
| ipen.autor | ANA FIGUEIREDO MAIA | |
| ipen.codigoautor | 1495 | |
| ipen.codigoautor | 2991 | |
| ipen.contributor.ipenauthor | LINDA V. E. CALDAS | |
| ipen.contributor.ipenauthor | ANA FIGUEIREDO MAIA | |
| ipen.date.recebimento | 06-01 | pt_BR |
| ipen.identifier.fi | 2.683 | pt_BR |
| ipen.identifier.ipendoc | 11128 | pt_BR |
| ipen.identifier.iwos | WoS | pt_BR |
| ipen.range.fi | 1.500 - 2.999 | |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | 7f46d4f4-dfd6-4485-a767-10df5b4f4f13 | |
| relation.isAuthorOfPublication | de6ea8e6-1554-4d6d-b73a-40e3df506cd9 | |
| relation.isAuthorOfPublication.latestForDiscovery | de6ea8e6-1554-4d6d-b73a-40e3df506cd9 | |
| sigepi.autor.atividade | MAIA, A.F.:2991:28:S | pt_BR |
| sigepi.autor.atividade | CALDAS, L.V.E.:1495:28:N | pt_BR |
Pacote Original