dc.description.abstractThe sandblasted, large-grit and acid-etched (SLA) surface is easy to be contaminated during storage and its surface chemical state is usually changed by different sterilization methods. This causes an undesirable increase in surface hydrophobicity and results in osseointegration degradation. To overcome this problem, a low temperature hydrothermal (HT) sterilization method was proposed in this study. Briefly, 4 weeks-stored pure titanium SLA specimens were sterilized using a sealed glass bottle with pure water in an autoclave set at 121 °C for 20 min. Results showed that, stored SLA specimens were superhydrophobic before and after conventional autoclaving, whereas, HT sterilization decontaminated and endowed stored SLA surface with superhydrophilicity. Osteoblast spreading was greatly enhanced, ALP expression was upgraded and bone nodule formation was obviously promoted on HT sterilized specimens compared with autoclaved ones. More bone formation around HT sterilized specimens was observed and HT sterilization increased bonding strength of implant to bone by 95% and 127% after 2 and 4 weeks of healing, respectively. The simple, feasible HT sterilization restored osseointegration of SLA implant while diminishing recontamination as much as possible. Therefore, it is proposed as a standard sterilization method for implant practitioners and researches.
dc.format.extent312-319pt_BR
dc.identifier.citationSHI, XINGLING; XU, LINGLI; VIOLIN, KALAN B.; LU, SHENG. Improved osseointegration of long-term stored SLA implant by hydrothermal sterilization. <b>Journal of the Mechanical Behavior of Biomedical Materials</b>, v. 53, p. 312-319, 2016. Disponível em: http://repositorio.ipen.br/handle/123456789/26655.
dc.identifier.issn1751-6161pt_BR
dc.identifier.percentilfi63.85
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/26655
dc.identifier.vol53pt_BR
dc.language.isoeng
dc.relation.ispartofJournal of the Mechanical Behavior of Biomedical Materialspt_BR
dc.rightsopenAccesspt_BR
dc.subjectimplants
dc.subjectsterilization
dc.subjectautoclaves
dc.subjectconnective tissue cells
dc.subjectbone tissues
dc.subjectbone cells
dc.subjectcell cultures
dc.subjectalkaline phosphatase
dc.subjectmineralization
dc.titleImproved osseointegration of long-term stored SLA implant by hydrothermal sterilizationpt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorKALAN BASTOS VIOLIN
ipen.codigoautor9545
ipen.contributor.ipenauthorKALAN BASTOS VIOLIN
ipen.date.recebimento16-09pt_BR
ipen.identifier.fi3.110pt_BR
ipen.identifier.ipendoc22558pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi3.000 - 4.499
ipen.range.percentilfi50.00 - 74.99
ipen.type.genreArtigo
relation.isAuthorOfPublication7389e571-bcff-430b-914a-c528ef8a19d1
relation.isAuthorOfPublication.latestForDiscovery7389e571-bcff-430b-914a-c528ef8a19d1
sigepi.autor.atividadeVIOLIN, KALAN B.:9545:720:N

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
22558.pdf
Tamanho:
1.58 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções