Evaluation of TL and OSL response of CaF2:Tm for electron beams dosimetry in radiation processing

dc.contributor.authorASFORA, V.K.
dc.contributor.authorANTONIO, P.L.
dc.contributor.authorBARROS, V.S.M. de
dc.contributor.authorGONCALVES, J.A.C.
dc.contributor.authorYAMATO, M.E.
dc.contributor.authorBUENO, C.C.
dc.contributor.authorCALDAS, L.V.E.
dc.contributor.authorKHOURY, H.J.
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL CONFERENCE ON APPLICATIONS OF RADIATION SCIENCE AND TECHNOLOGYpt_BR
dc.date.accessioned2017-09-22T12:35:49Z
dc.date.available2017-09-22T12:35:49Z
dc.date.eventoApril 24-28, 2017pt_BR
dc.description.abstractAn increasing number of pytosanitary irradiations using electron beams has encouraged the development of surface dosimetry systems to cope with both lowand intermediate absorbed doses and dose rates. Besides thewell-established reference and routine dosimeters, ranging from alanine to radiochromic films, there is an interest in dosimeters based on thermoluminescence (TL) and optically stimulated luminescence (OSL) effects. In this context, the aim of this paper is to study the TL and infrared stimulated luminescence (IRSL) response of the calcium fluoride dosimeter doped with thulium (CaF2:Tm) produced via combustion synthesis (CS) by the Nuclear Energy Department of Federal University of Pernambuco, Brazil. The pellets with 6mmin diameter and 1mmthicknesswere obtained by pressing the powder using 10% PTFE as binder material. The individual TL and OSL sensitivities of the dosimeters of the batch were previously evaluated and a group of 50 pellets with a standard deviation of 6:8% was selected to be used in this study. After that, the performance of these dosimeters to electron beams with 1:5 MeV from a DC 1500/25/4 – JOB 188 Accelerator at the Radiation Technology Center at IPEN-CNEN/SP was investigated. For each dose, four pellets of CaF2:Tm, together with four pellets of alanine were irradiated with doses from 0:5 kGy up to 10 kGy. The TL and OSL readings were carried out after a preheating at 100 C during 15 min using a Riso TL/OSL reader, model DA-20. The TL measurements were taken with a heating rate of 2 C/s, in the range from 50 C to 350 C. The OSL readings were carried out with infrared stimulation with optical power attenuated to 20% during 240 s. These readings were thermally assisted at 150 C. Residual thermoluminescent glow curves for IRSL were recorded after stimulation times. The reproducibility and stability of the TL and IRSL responses were also evaluated, as well as the dependence with different dose rates. The results showed that the main TL peak of the glow is in the region of 200 C and it was observed that the IRSL curve of the dosimeters presents a fast and a slow decaying IRSL signals. The TL and OSL dose response curves were fitted by a second order polynomial function with correlation coefficients of 0:97 and 0:99, respectively. The results indicated the possibility of the application of CaF2:Tm for electron beam dosimetry in radiation processing.pt_BR
dc.event.siglaICARSTpt_BR
dc.format.extent429-429pt_BR
dc.identifier.citationASFORA, V.K.; ANTONIO, P.L.; BARROS, V.S.M. de; GONCALVES, J.A.C.; YAMATO, M.E.; BUENO, C.C.; CALDAS, L.V.E.; KHOURY, H.J. Evaluation of TL and OSL response of CaF2:Tm for electron beams dosimetry in radiation processing. In: INTERNATIONAL CONFERENCE ON APPLICATIONS OF RADIATION SCIENCE AND TECHNOLOGY, April 24-28, 2017, Vienna, Austria. <b>Abstract...</b> Vienna: IAEA, 2017. p. 429-429. Disponível em: http://repositorio.ipen.br/handle/123456789/27780.
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.orcidhttps://orcid.org/0000-0001-7881-7254
dc.identifier.orcidhttps://orcid.org/0000-0002-8940-9544
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/27780
dc.localViennapt_BR
dc.local.eventoVienna, Austriapt_BR
dc.publisherIAEApt_BR
dc.rightsopenAccesspt_BR
dc.titleEvaluation of TL and OSL response of CaF2:Tm for electron beams dosimetry in radiation processingpt_BR
dc.typeResumo de eventos científicospt_BR
dspace.entity.typePublication
ipen.autorLINDA V. E. CALDAS
ipen.autorCARMEN CECILIA BUENO TOBIAS
ipen.autorJOSEMARY ANGELICA CORREA GONCALVES
ipen.autorPATRICIA DE LARA ANTONIO
ipen.codigoautor1495
ipen.codigoautor1592
ipen.codigoautor924
ipen.codigoautor6585
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.contributor.ipenauthorCARMEN CECILIA BUENO TOBIAS
ipen.contributor.ipenauthorJOSEMARY ANGELICA CORREA GONCALVES
ipen.contributor.ipenauthorPATRICIA DE LARA ANTONIO
ipen.date.recebimento17-09pt_BR
ipen.event.datapadronizada2017pt_BR
ipen.identifier.ipendoc23068pt_BR
ipen.notas.internasAbstractpt_BR
ipen.type.genreResumo
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublicationfa74399b-83a0-4f46-91e0-da469104d3f6
relation.isAuthorOfPublication76fdc4d1-7624-4332-a9d0-f06826000679
relation.isAuthorOfPublication5ea4ca8b-8415-4439-81d2-6fe0d6debd42
relation.isAuthorOfPublication.latestForDiscovery5ea4ca8b-8415-4439-81d2-6fe0d6debd42
sigepi.autor.atividadeANTONIO, P.L.:6585:330:Npt_BR
sigepi.autor.atividadeGONCALVES, J.A.C.:924:240:Npt_BR
sigepi.autor.atividadeBUENO, C.C.:1592:240:Npt_BR
sigepi.autor.atividadeCALDAS, L.V.E.:1495:330:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
23068.pdf
Tamanho:
203.6 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: