Method to evaluate the L/D ratio of neutron imaging beams
| dc.contributor.author | PUGLIESI, R. | |
| dc.contributor.author | PEREIRA, M.A.S. | |
| dc.contributor.author | SCHOUERI, R.M. | |
| dc.coverage | Nacional | pt_BR |
| dc.date.accessioned | 2017-09-27T11:36:03Z | |
| dc.date.available | 2017-09-27T11:36:03Z | |
| dc.date.issued | 2017 | pt_BR |
| dc.description.abstract | An alternative simple method to evaluate the L/D ratio of neutron imaging beams is proposed. It is based on the behavior of the ratio “x/Ut”, which asymptotically tends to L/D for large values of the parameter “x”, that corresponds to the distance separating a gadolinium test object to the scintillator plane, where its image is formed. The method was applied to the neutron imaging equipment of the Nuclear and Energy Research Institute IPENCNEN/ SP and the obtained result was L/D = (104 ± 4). The consistency of the proposed method was verified by comparing this value with those ones obtained by a well - known and established procedure. | pt_BR |
| dc.format.extent | 01-07 | pt_BR |
| dc.identifier.citation | PUGLIESI, R.; PEREIRA, M.A.S.; SCHOUERI, R.M. Method to evaluate the L/D ratio of neutron imaging beams. <b>Brazilian Journal of Radiation Sciences</b>, v. 5, n. 1, p. 01-07, 2017. DOI: <a href="https://dx.doi.org/10.15392/bjrs.v5i1.257">10.15392/bjrs.v5i1.257</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/27798. | |
| dc.identifier.doi | 10.15392/bjrs.v5i1.257 | |
| dc.identifier.fasciculo | 1 | pt_BR |
| dc.identifier.issn | 2319-0612 | pt_BR |
| dc.identifier.percentilfi | Sem Percentil | en |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/27798 | |
| dc.identifier.vol | 5 | pt_BR |
| dc.relation.ispartof | Brazilian Journal of Radiation Sciences | pt_BR |
| dc.rights | openAccess | pt_BR |
| dc.subject | beams | |
| dc.subject | digital systems | |
| dc.subject | images | |
| dc.subject | neutron flux | |
| dc.subject | neutrons | |
| dc.subject | spatial resolution | |
| dc.subject | tomography | |
| dc.subject | brazil | |
| dc.subject | brazil | |
| dc.title | Method to evaluate the L/D ratio of neutron imaging beams | pt_BR |
| dc.type | Artigo de periódico | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | ROBERTO MAURO SCHOUERI | |
| ipen.autor | MARCO ANTONIO STANOJEV PEREIRA | |
| ipen.autor | REYNALDO PUGLIESI | |
| ipen.codigoautor | 534 | |
| ipen.codigoautor | 2133 | |
| ipen.codigoautor | 1391 | |
| ipen.contributor.ipenauthor | ROBERTO MAURO SCHOUERI | |
| ipen.contributor.ipenauthor | MARCO ANTONIO STANOJEV PEREIRA | |
| ipen.contributor.ipenauthor | REYNALDO PUGLIESI | |
| ipen.date.recebimento | 17-09 | pt_BR |
| ipen.identifier.fi | Sem F.I. | pt_BR |
| ipen.identifier.ipendoc | 23100 | pt_BR |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | 956ece9b-195e-49d3-bbd2-4be354492d5e | |
| relation.isAuthorOfPublication | 0192edfe-c986-47f3-a384-7dd4093ff566 | |
| relation.isAuthorOfPublication | 7c9b511e-1210-4f64-8a4c-c3546c3f7876 | |
| relation.isAuthorOfPublication.latestForDiscovery | 7c9b511e-1210-4f64-8a4c-c3546c3f7876 | |
| sigepi.autor.atividade | PUGLIESI, R.:1391:310:S | pt_BR |
| sigepi.autor.atividade | PEREIRA, M.A.S.:2133:310:N | pt_BR |
| sigepi.autor.atividade | SCHOUERI, R.M.:534:310:N | pt_BR |