TL response study of the CaSO4 : Dy pellets with graphite for dosimetry in beta radiation and low-energy photons fields

dc.contributor.authorDAROS, K.A.C.pt_BR
dc.contributor.authorCAMPOS, L.L.pt_BR
dc.contributor.authorMEDEIROS, R.B.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2014-07-30T17:22:38Zpt_BR
dc.date.accessioned2014-07-30T19:00:08Z
dc.date.available2014-07-30T17:22:38Zpt_BR
dc.date.available2014-07-30T19:00:08Z
dc.date.issued2001pt_BR
dc.description.abstractThe CaSO4:Dy is a good thermoluminescent dosimeter because of its high sensitivity and low cost. With graphite in the pellets it is possible to reduce the energy dependence. The sensitivity and energy dependence of the different thicknesses of CaSO4:Dy pellets was studied with different amounts of graphite. The results have shown the optimal quantity of the graphite and the appropriate thickness of the pellets that can be used in dosimetry of beta field, photons or both simultaneously.
dc.format.extent957-960pt_BR
dc.identifier.citationDAROS, K.A.C.; CAMPOS, L.L.; MEDEIROS, R.B. TL response study of the CaSO4 : Dy pellets with graphite for dosimetry in beta radiation and low-energy photons fields. <b>Applied Radiation and Isotopes</b>, v. 54, n. 6, p. 957-960, 2001. DOI: <a href="https://dx.doi.org/10.1016/S0969-8043(00)00324-9">10.1016/S0969-8043(00)00324-9</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/6208.
dc.identifier.doi10.1016/S0969-8043(00)00324-9
dc.identifier.fasciculo6pt_BR
dc.identifier.issn0969-8043pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-7137-0613
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/6208pt_BR
dc.identifier.vol54pt_BR
dc.relation.ispartofApplied Radiation and Isotopespt_BR
dc.rightsopenAccessen
dc.subjectcalcium sulfatespt_BR
dc.subjectdysprosiumpt_BR
dc.subjectteflonpt_BR
dc.subjectgraphitept_BR
dc.subjectthermoluminescencept_BR
dc.subjectenergy dependencept_BR
dc.subjectsensitivitypt_BR
dc.subjectthermoluminescent dosemeterspt_BR
dc.subjectbeta dosimetrypt_BR
dc.subjectgamma dosimetrypt_BR
dc.titleTL response study of the CaSO4 : Dy pellets with graphite for dosimetry in beta radiation and low-energy photons fieldspt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorREGINA BITELLI MEDEIROS
ipen.autorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.codigoautor9848
ipen.codigoautor1195
ipen.contributor.ipenauthorREGINA BITELLI MEDEIROS
ipen.contributor.ipenauthorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.date.recebimento00-12pt_BR
ipen.identifier.fi0.635pt_BR
ipen.identifier.ipendoc06183pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi0.001 - 1.499
ipen.type.genreArtigo
relation.isAuthorOfPublication69a7785e-95c6-482a-b930-45990da38add
relation.isAuthorOfPublicationd4d34119-a6e6-4026-9a67-7b16d8b668da
relation.isAuthorOfPublication.latestForDiscoveryd4d34119-a6e6-4026-9a67-7b16d8b668da
sigepi.autor.atividadeCAMPOS, L.L.:1195:28:Npt_BR
sigepi.autor.atividadeMEDEIROS, R.B.:9848:-1:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
06183.pdf
Tamanho:
147.67 KB
Formato:
Adobe Portable Document Format

Coleções