Monte Carlo dosimetric evaluation in PET exams for patients with different BMI and heights

dc.contributor.authorBELINATO, WALMIR
dc.contributor.authorSILVA, ROGERIO M.V.
dc.contributor.authorPERINI, ANA P.
dc.contributor.authorNEVES, LUCIO P.
dc.contributor.authorSANTOS, CARLA J.
dc.contributor.authorSOUZA, DIVANIZIA N.
dc.contributor.authorSANTOS, WILLIAM S.
dc.coverageInternacionalpt_BR
dc.date.accessioned2018-07-11T19:24:22Z
dc.date.available2018-07-11T19:24:22Z
dc.date.issued2018pt_BR
dc.description.abstractIn recent years, positron emission tomography (PET), associated with multi-detector computed tomography (MDCT), has become a diagnostic technique widely disseminated to evaluate various malignant tumors and other diseases. However, during PET/CT examinations, the doses of ionizing radiation experienced by the internal organs of the patients due to 18F are unknown, and may be substantial. The aim of this study was to determine a set of S values derived from the 18F-FDG and to use them to determine the absorbed and effective doses of 8 different virtual anthropomorphic phantoms (4 of each gender). These phantoms have different Body Mass Index (BMI), to represent different anatomical characteristics of patients examined in PET. The results of the S values were calculated using the MCNPX (2.7.0) Monte Carlo code. These results were compared to the ICRP 106 reference values, obtained with mathematical anthropomorphic phantoms (MIRD model). Our results of the S values were higher than those obtained and presented at the ICRP 106, mainly due to the differences between the phantoms. The differences between the relative distances of the organs and the chemical and physical characteristics of the phantoms used in this study, in relation to mathematical model, reflected the use of a detailed set of phantoms. Therefore, the results presented in this study provide accurate and reliable data for internal dose calculations for patients undergoing PET examinations.pt_BR
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de Minas Gerais (FAPEMIG)pt_BR
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)pt_BR
dc.description.sponsorshipIDFAPEMIG: APQ-03049- 15; APQ-02934-15pt_BR
dc.description.sponsorshipIDCNPq: 421603/2016-0; 420699/2016-3; 168947/2017-0pt_BR
dc.format.extent36-41pt_BR
dc.identifier.citationBELINATO, WALMIR; SILVA, ROGERIO M.V.; PERINI, ANA P.; NEVES, LUCIO P.; SANTOS, CARLA J.; SOUZA, DIVANIZIA N.; SANTOS, WILLIAM S. Monte Carlo dosimetric evaluation in PET exams for patients with different BMI and heights. <b>Radiation Physics and Chemistry</b>, v. 151, p. 36-41, 2018. DOI: <a href="https://dx.doi.org/10.1016/j.radphyschem.2018.05.011">10.1016/j.radphyschem.2018.05.011</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/28928.
dc.identifier.doi10.1016/j.radphyschem.2018.05.011pt_BR
dc.identifier.issn0969-806Xpt_BR
dc.identifier.percentilfi53.70en
dc.identifier.percentilfiCiteScore61.00
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/28928
dc.identifier.vol151pt_BR
dc.relation.ispartofRadiation Physics and Chemistrypt_BR
dc.rightsopenAccesspt_BR
dc.subjectpositron computed tomography
dc.subjectmonte carlo method
dc.subjectpositron sources
dc.subjectdosimetry
dc.subjectphantoms
dc.titleMonte Carlo dosimetric evaluation in PET exams for patients with different BMI and heightspt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorANA PAULA PERINI
ipen.codigoautor8787
ipen.contributor.ipenauthorANA PAULA PERINI
ipen.date.recebimento18-07pt_BR
ipen.identifier.fi1.984pt_BR
ipen.identifier.fiCiteScore2.9
ipen.identifier.ipendoc24712pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi1.500 - 2.999
ipen.range.percentilfi50.00 - 74.99
ipen.type.genreArtigo
relation.isAuthorOfPublication6ba9097c-31f2-4f8e-8649-ba14ba3677ef
relation.isAuthorOfPublication.latestForDiscovery6ba9097c-31f2-4f8e-8649-ba14ba3677ef
sigepi.autor.atividadePERINI, ANA P.:8787:330:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
24712.pdf
Tamanho:
628.24 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções