Effect of mounting orientation on testing equipment on elastic compliance of clamped SE(T) specimens
Carregando...
Data
Data de publicação
Orientador
Título da Revista
ISSN da Revista
Título do Volume
É parte de
É parte de
É parte de
Brazilian Journal of Radiation Sciences
Resumo
The accurate evaluation of fracture mechanics properties is key to the safety of operation of high responsibility structures, such as nuclear reactor components. This paper evaluates the impact of mounting orientation on the test machine of clamped SE(T) (SE(T)c) specimens on their compliance. The elastic unloading compliance is a commonly used technique to measure the crack depth of specimens within fracture mechanics tests. Inaccurate measurements affect the reliability of resulting properties. Two mounting orientations are evaluated in this paper, together with two SE(T)c specimens with different width-to-thickness ratios (W/B=2 and W/B=4). The conclusions show that machine stiffness is different in the two orientations, and that this value has the potential to affect crack depth prediction. On the other hand, the analysis scope of this work was unable to detect significant differences between the two orientations, probably because loading was limited to maintain specimen integrity. Further investigation is necessary to precisely address the impact of this effect.
Como referenciar
ANDRADE, L.G.F.; DONATO, G.H.B.; MATTAR NETO, M. Effect of mounting orientation on testing equipment on elastic compliance of clamped SE(T) specimens: an exploration. Brazilian Journal of Radiation Sciences, v. 10, n. 3A, p. 1-21, 2022. DOI: 10.15392/2319-0612.2022.1863. Disponível em: http://repositorio.ipen.br/handle/123456789/33480. Acesso em: 30 Dec 2025.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.