dc.description.abstractIntroduction Quality assurance in radiation therapy included all actions for ensure the maximum dose for the target volume (tumour) and minimum dose for the healthy tissues. The use of thermoluminescent detectors for evaluation of the absorbed doses in treatments that involve the use of ionizing radiation is widespread and well established in clinical routine. The quality measures are employed to validate system performance, such as IMRT quality assurance (QA). An example for IMRT QA is the decision not to treat the patient if the comparison between a point-dose measurement and the planned value exceeds a predefi ned acceptance criterion (±5%). This work aimed the evaluation of absorbed doses with the use of thermoluminescent detectors (TLDs) of lithium fl uoride doped with magnesium and titanium (LiF:Mg,Ti) and a polymethylmethacrylate (PMMA) phantom in Intensity Modulated Radiation Therapy – IMRT planning. Methods In this study the PMMA phantom simulated a patient in treatment. The central cavity (rectangular format) was considered like target volume (tumour) and the others four cavities were considered like organs at risk. The TLDs were positioned inside the cavities; each cavity has an EVA mold for the positioning of TLDs.pt_BR
dc.event.siglaICDApt_BR
dc.identifier.citationMATSUSHIMA, L.C.; VENEZIANI, G.R.; SAKURABA, R.K.; CAMPOS, L.L. Quality control in “Intensity Modulated Radiation Therapy-IMRT” using thermoluminescent dosimeters. In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 3rd, May 27-31, 2019, Lisboa, Portugal. <b>Abstract...</b> Lisboa, Portugal: C2TN, Instituto Superior Técnico, Universidade de Lisboa, 2019. Disponível em: http://repositorio.ipen.br/handle/123456789/31019.
dc.identifier.orcid0000-0001-7137-0613pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-7137-0613
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/31019
dc.localLisboa, Portugalpt_BR
dc.local.eventoLisboa, Portugalpt_BR
dc.publisherC2TN, Instituto Superior Técnico, Universidade de Lisboapt_BR
dc.rightsopenAccesspt_BR
dc.titleQuality control in “Intensity Modulated Radiation Therapy-IMRT” using thermoluminescent dosimeterspt_BR
dc.typeResumo de eventos científicospt_BR
dspace.entity.typePublication
ipen.autorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.autorGLAUCO ROGERIO VENEZIANI
ipen.codigoautor1195
ipen.codigoautor8988
ipen.contributor.ipenauthorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.contributor.ipenauthorGLAUCO ROGERIO VENEZIANI
ipen.date.recebimento20-03
ipen.event.datapadronizada2019pt_BR
ipen.identifier.ipendoc26814pt_BR
ipen.notas.internasAbstractpt_BR
ipen.type.genreResumo
relation.isAuthorOfPublicationd4d34119-a6e6-4026-9a67-7b16d8b668da
relation.isAuthorOfPublication8cc42bbc-1896-4124-b001-530bf4ab2773
relation.isAuthorOfPublication.latestForDiscovery8cc42bbc-1896-4124-b001-530bf4ab2773
sigepi.autor.atividadeCAMPOS, L.L.:1195:330:Npt_BR
sigepi.autor.atividadeVENEZIANI, G.R.:8988:-1:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
26814.pdf
Tamanho:
1007.29 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: