A CFD analysis of blockage length on a partially blocked fuel rod
Carregando...
Data
Data de publicação
Orientador
Título da Revista
ISSN da Revista
Título do Volume
É parte de
É parte de
É parte de
Brazilian Journal of Radiation Sciences
Resumo
After a loss of coolant accident (LOCA), fuel rods may balloon. The swelling can partially block the flow channel, affecting the coolability during reflood phase. In order to analyze the influence of blockage length, using a radial block-age of 90%, varying just the blockage length, many steady state numerical simulations has been done using Ansys-CFX code to verify thermal-hydraulic properties according to different forced cooled conditions. Temperature peaks are observed on cladding, followed by a temperature drop. A 5x5 fuel assembly, with 9 centered ballooned fuel rod, flow redistribution inside channels can also be captured, indicating an overheating zone. Therefore, this study conclude, for the same boundary conditions, the longer the blockage length originated after LOCA events, the higher are the clad temperatures, indicating the possibility of overheat during transient conditions on reflood.
Como referenciar
SCURO, N.L.; UMBEHAUN, P.E.; ANGELO, E.; ANGELO, G.; ANDRADE, D.A. A CFD analysis of blockage length on a partially blocked fuel rod. Brazilian Journal of Radiation Sciences, v. 7, n. 2B, p. 1-20, 2019. DOI: 10.15392/bjrs.v7i2B.437. Disponível em: http://repositorio.ipen.br/handle/123456789/30369. Acesso em: 20 Mar 2026.