A dose calculation model application for indoor exposure to two-layer walls gamma irradiation: the case study of ceramic tiles

dc.contributor.authorRIGHI, SERENA
dc.contributor.authorVERITA, SIMONA
dc.contributor.authorROSSI, PIER L.
dc.contributor.authorMADUAR, MARCELO F.
dc.coverageInternacionalpt_BR
dc.date.accessioned2017-04-07T17:42:33Z
dc.date.available2017-04-07T17:42:33Z
dc.date.issued2016pt_BR
dc.description.abstractA calculation model for determining the indoor dose due to building materials with significant concentration of radioactivity has been applied to the case study of ceramic tiles; the model allows the contribution of bearing walls and wall covering materials to be calculated. The model is implemented in FORTRAN 77 and provides a quantification of the gamma radiation field (in terms of external dose rate in air, nGyh21) inside a room with known dimensions. Application model results have been validated both by comparison with the results obtained by other authors and by experimental measurements. Model sensitivity and performances have been analysed and lastly the case studies focused on ceramic tiles have been proposed.pt_BR
dc.format.extent545-553pt_BR
dc.identifier.citationRIGHI, SERENA; VERITA, SIMONA; ROSSI, PIER L.; MADUAR, MARCELO F. A dose calculation model application for indoor exposure to two-layer walls gamma irradiation: the case study of ceramic tiles. <b>Radiation Protection Dosimetry</b>, v. 171, n. 4, p. 545-553, 2016. DOI: <a href="https://dx.doi.org/10.1093/rpd/ncv476">10.1093/rpd/ncv476</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/27365.
dc.identifier.doi10.1093/rpd/ncv476pt_BR
dc.identifier.fasciculo4pt_BR
dc.identifier.issn0144-8420pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-4448-003X
dc.identifier.percentilfi21.42
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/27365
dc.identifier.vol171pt_BR
dc.relation.ispartofRadiation Protection Dosimetrypt_BR
dc.rightsclosedAccesspt_BR
dc.subjectbuilding materials
dc.subjectceramics
dc.subjectconcentration ratio
dc.subjectdose rates
dc.subjectfortran
dc.subjectgamma radiation
dc.subjectperformance
dc.subjectradiation doses
dc.subjectradioactivity
dc.subjectradioecological concentration
dc.subjectsensitivity
dc.titleA dose calculation model application for indoor exposure to two-layer walls gamma irradiation: the case study of ceramic tilespt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorMARCELO FRANCIS MADUAR
ipen.codigoautor766
ipen.contributor.ipenauthorMARCELO FRANCIS MADUAR
ipen.date.recebimento17-04pt_BR
ipen.identifier.fi0.917pt_BR
ipen.identifier.ipendoc23539pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi0.001 - 1.499
ipen.range.percentilfi0.00 - 24.99
ipen.type.genreArtigo
relation.isAuthorOfPublicationd1f31f36-41a6-454e-b032-2d816cd74987
relation.isAuthorOfPublication.latestForDiscoveryd1f31f36-41a6-454e-b032-2d816cd74987
sigepi.autor.atividadeMADUAR, MARCELO F.:766:340:Npt_BR
Pacote Original
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
23539.pdf
Tamanho:
434.87 KB
Formato:
Adobe Portable Document Format
Descrição:
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Coleções