Study and calibration of the HPGe detector for radionuclide analysis of iodine-125

dc.contributor.authorCORREIA, RUANYTO W.pt_BR
dc.contributor.authorROSTELATO, MARIA E.C.M.pt_BR
dc.contributor.authorZEITUNI, CARLOS A.pt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL NUCLEAR ATLANTIC CONFERENCEpt_BR
dc.date.accessioned2019-11-27T18:30:55Z
dc.date.available2019-11-27T18:30:55Z
dc.date.eventoOctober 21-25, 2019pt_BR
dc.description.abstractIn this work, a theoretical-experimental methodology was developed for the calibration of HPGe Detector for quantitative analysis of iodine-125. Photopick efficiencies was measured between 0 - 40 keV using a certified calibration source (iodine-129) with well-known activity. The efficiency curve was determined for an energy range that covers the region of interest for iodine-125 (0 - 40 keV). The calibrate spectrum was obtained for study and the result was saved in the detector directory for future analysis and determination of the iodine-125 activity.pt_BR
dc.event.siglaINACpt_BR
dc.format.extent370-382pt_BR
dc.identifier.citationCORREIA, RUANYTO W.; ROSTELATO, MARIA E.C.M.; ZEITUNI, CARLOS A. Study and calibration of the HPGe detector for radionuclide analysis of iodine-125. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. <b>Proceedings...</b> Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 370-382. Disponível em: http://repositorio.ipen.br/handle/123456789/30360.
dc.identifier.orcid0000-0002-7303-6720pt_BR
dc.identifier.orcid0000-0003-2943-6097pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-7303-6720
dc.identifier.orcidhttps://orcid.org/0000-0003-2943-6097
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/30360
dc.localRio de Janeiropt_BR
dc.local.eventoSantos, SPpt_BR
dc.publisherAssociação Brasileira de Energia Nuclear
dc.rightsopenAccesspt_BR
dc.subjectcalibration
dc.subjectcomputer codes
dc.subjecthigh-purity ge detectors
dc.subjectiodine 125
dc.subjectquantitative chemical analysis
dc.titleStudy and calibration of the HPGe detector for radionuclide analysis of iodine-125pt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorCARLOS ALBERTO ZEITUNI
ipen.autorMARIA ELISA CHUERY MARTINS ROSTELATO
ipen.autorRUANYTO WILLY CORREIA
ipen.codigoautor944
ipen.codigoautor7
ipen.codigoautor14979
ipen.contributor.ipenauthorCARLOS ALBERTO ZEITUNI
ipen.contributor.ipenauthorMARIA ELISA CHUERY MARTINS ROSTELATO
ipen.contributor.ipenauthorRUANYTO WILLY CORREIA
ipen.date.recebimento19-11
ipen.event.datapadronizada2019pt_BR
ipen.identifier.ipendoc26143pt_BR
ipen.notas.internasProceedingspt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication02421b96-adef-4759-b25e-67d4759aa676
relation.isAuthorOfPublicationda77b491-04ff-4c68-aa65-dead9208a48c
relation.isAuthorOfPublicationc9418bf2-189a-4968-8f04-723d75fcddb1
relation.isAuthorOfPublication.latestForDiscoveryc9418bf2-189a-4968-8f04-723d75fcddb1
sigepi.autor.atividadeZEITUNI, CARLOS A.:944:230:Npt_BR
sigepi.autor.atividadeROSTELATO, MARIA E.C.M.:7:230:Npt_BR
sigepi.autor.atividadeCORREIA, RUANYTO W.:14979:230:Spt_BR
Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
26143.pdf
Tamanho:
943.64 KB
Formato:
Adobe Portable Document Format
Descrição:
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Coleções