On neutron activation analysis with gamma gamma coincidence spectrometry

dc.contributor.authorZEISLER, ROLF
dc.contributor.authorCHO, HANA
dc.contributor.authorRIBEIRO JUNIOR, IBERE S.
dc.contributor.authorSHETTY, MARTIN G.
dc.contributor.authorTURKOGLU, DANYAL
dc.coverageInternacionalpt_BR
dc.date.accessioned2017-10-17T12:38:08Z
dc.date.available2017-10-17T12:38:08Z
dc.date.issued2017pt_BR
dc.description.abstractA new gamma gamma coincidence system has been set up at NIST. It is operated with a digital data finder supported by new software developed at NIST. The system is used to explore possible enhancements in instrumental neutron activation analysis (INAA) and study applicability to neutron capture prompt gamma activation analysis (PGAA). The performance of the system is tested with certified reference materials for efficiency calibration and quantitative performance. Comparisons of INAA results based on conventional gamma-ray spectrometry data with INAA results based on coincidence data obtained from the same samples show improvements in the counting uncertainties and demonstrates the quantitative accuracy of the new system.pt_BR
dc.format.extent513-519pt_BR
dc.identifier.citationZEISLER, ROLF; CHO, HANA; RIBEIRO JUNIOR, IBERE S.; SHETTY, MARTIN G.; TURKOGLU, DANYAL. On neutron activation analysis with gamma gamma coincidence spectrometry. <b>Journal of Radioanalytical and Nuclear Chemistry</b>, v. 314, n. 1, p. 513-519, 2017. DOI: <a href="https://dx.doi.org/10.1007/s10967-017-5342-7">10.1007/s10967-017-5342-7</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/27914.
dc.identifier.doi10.1007/s10967-017-5342-7pt_BR
dc.identifier.fasciculo1pt_BR
dc.identifier.issn0236-5731pt_BR
dc.identifier.percentilfi36.52en
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/27914
dc.identifier.vol314pt_BR
dc.relation.ispartofJournal of Radioanalytical and Nuclear Chemistrypt_BR
dc.rightsopenAccesspt_BR
dc.subjectaccuracy
dc.subjectcalibration standards
dc.subjectcoincidence spectrometry
dc.subjectdata processing
dc.subjectgamma spectroscopy
dc.subjectneutron activation analysis
dc.subjectprompt gamma radiation
dc.titleOn neutron activation analysis with gamma gamma coincidence spectrometrypt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorIBERE SOUZA RIBEIRO JUNIOR
ipen.codigoautor10189
ipen.contributor.ipenauthorIBERE SOUZA RIBEIRO JUNIOR
ipen.date.recebimento17-10pt_BR
ipen.identifier.fi1.181pt_BR
ipen.identifier.ipendoc23226pt_BR
ipen.identifier.iwosAguardar WoSpt_BR
ipen.range.fi0.001 - 1.499
ipen.range.percentilfi25.00 - 49.99
ipen.type.genreArtigo
relation.isAuthorOfPublicationa978a384-2cd4-4fe3-8a0e-454eca29efe1
relation.isAuthorOfPublication.latestForDiscoverya978a384-2cd4-4fe3-8a0e-454eca29efe1
sigepi.autor.atividadeRIBEIRO JUNIOR, IBERE S.:10189:310:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
23226.pdf
Tamanho:
953.01 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções