Medições espectrofotométricas da oxidação no dosímetro químico Fricke Xylenol Gel (FXG): avaliação das disposições das amostras pós-irradiações

dc.contributor.authorOLIVEIRA, L.N.
dc.contributor.authorALMEIDA, A.
dc.contributor.authorCALDAS, L.V.E.
dc.coverageInternacionalpt_BR
dc.date.accessioned2017-01-19T10:40:14Z
dc.date.available2017-01-19T10:40:14Z
dc.date.issued2016pt_BR
dc.description.abstractThe spectrophotometric method was used for oxidation determination in chemical gel dosimeter. The method based on the reaction of the Fe2+ to Fe3+ lead to increases in the magnitude of the absorbance signal monitored at 585 nm. The chemical dosimeter was irradiated and maintained in the horizontal and vertical positions with and without cover for the analysis of oxidation due to radiation or contact with oxygen. The method was successfully applied for oxidation determination in Fricke Xylenol Gel (FXG), and the results agree with the better accommodation position of this chemical gel dosimeter.pt_BR
dc.format.extent153-161pt_BR
dc.identifier.citationOLIVEIRA, L.N.; ALMEIDA, A.; CALDAS, L.V.E. Medições espectrofotométricas da oxidação no dosímetro químico Fricke Xylenol Gel (FXG): avaliação das disposições das amostras pós-irradiações. <b>Holos</b>, v. 4, p. 153-161, 2016. DOI: <a href="https://dx.doi.org/10.15628/holos.2016.1890">10.15628/holos.2016.1890</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/26999.
dc.identifier.doi10.15628/holos.2016.1890pt_BR
dc.identifier.issn1807-1600pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/26999
dc.identifier.vol4pt_BR
dc.relation.ispartofHolospt_BR
dc.rightsopenAccesspt_BR
dc.subjectspectrophotometry
dc.subjectoxidation
dc.subjectdosemeters
dc.subjectirradiation
dc.subjectchemical dosemeters
dc.subjectcomparative evaluations
dc.subjectstorage
dc.titleMedições espectrofotométricas da oxidação no dosímetro químico Fricke Xylenol Gel (FXG): avaliação das disposições das amostras pós-irradiaçõespt_BR
dc.title.alternativeSpectrophotometric measurements of the oxidation in chemical dosimeter Fricke Xylenol Gel (FXG): evaluation of the provisions of the post-irradiation samplespt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorLINDA V. E. CALDAS
ipen.codigoautor1495
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.date.recebimento17-01pt_BR
ipen.identifier.fiSem F.I.pt_BR
ipen.identifier.ipendoc22835pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublication.latestForDiscovery7f46d4f4-dfd6-4485-a767-10df5b4f4f13
sigepi.autor.atividadeCALDAS, L.V.E.:1495:330:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
22835.pdf
Tamanho:
543.96 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções